Details
Originalsprache | Englisch |
---|---|
Titel des Sammelwerks | 2017 International Conference on Rehabilitation Robotics (ICORR) |
Seiten | 971-976 |
Seitenumfang | 6 |
ISBN (elektronisch) | 9781538622964 |
Publikationsstatus | Veröffentlicht - 2017 |
Publikationsreihe
Name | IEEE International Conference on Rehabilitation Robotics |
---|---|
ISSN (Print) | 1945-7898 |
ISSN (elektronisch) | 1945-7901 |
Abstract
Inertial Measurement Units (IMUs) have become a widely used tool for rehabilitation and other application domains in which human motion is analyzed using an ambulatory or wearable setup. Since the magnetic field is inhomogeneous in indoor environments and in the proximity of ferromagnetic material, standard orientation estimation and joint angle calculation algorithms often lead to inaccurate or even completely wrong results. One approach to circumvent this is to exploit the kinematic constraint that is induced by mechanical hinge joints and also by approximate hinge joints such as the knee joint and the finger (interphalangeal) joints of the human body. We propose a quaternion-based method for joint angle measurement for approximate hinge joints moving through inhomogeneous magnetic fields. The method exploits the kinematic constraint to compensate the error that the magnetic disturbances induce in the IMU orientation estimates. This is achieved by realtime estimation and correction of the relative heading (azimuth) error that is caused by the disturbance. Since the kinematic constraint does not allow heading correction when the joint axis is vertical, we extend the proposed method such that it improves accuracy and robustness when the joint is close to that singularity. We evaluate the method by simulations of a quick hand motion and study the effect of inaccurate sensor-to-segment (anatomical) calibration and joint constraint relaxations. As a main result, the proposed method is found to reduce the root-mean-square error of the joint angle from 25.8° to 2.6° in the presence of large magnetic disturbances.
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
2017 International Conference on Rehabilitation Robotics (ICORR). 2017. S. 971-976 8009375 (IEEE International Conference on Rehabilitation Robotics).
Publikation: Beitrag in Buch/Bericht/Sammelwerk/Konferenzband › Aufsatz in Konferenzband › Forschung › Peer-Review
}
TY - GEN
T1 - Exploiting kinematic constraints to compensate magnetic disturbances when calculating joint angles of approximate hinge joints from orientation estimates of inertial sensors
AU - Laidig, Daniel
AU - Schauer, Thomas
AU - Seel, Thomas
N1 - Publisher Copyright: © 2017 IEEE.
PY - 2017
Y1 - 2017
N2 - Inertial Measurement Units (IMUs) have become a widely used tool for rehabilitation and other application domains in which human motion is analyzed using an ambulatory or wearable setup. Since the magnetic field is inhomogeneous in indoor environments and in the proximity of ferromagnetic material, standard orientation estimation and joint angle calculation algorithms often lead to inaccurate or even completely wrong results. One approach to circumvent this is to exploit the kinematic constraint that is induced by mechanical hinge joints and also by approximate hinge joints such as the knee joint and the finger (interphalangeal) joints of the human body. We propose a quaternion-based method for joint angle measurement for approximate hinge joints moving through inhomogeneous magnetic fields. The method exploits the kinematic constraint to compensate the error that the magnetic disturbances induce in the IMU orientation estimates. This is achieved by realtime estimation and correction of the relative heading (azimuth) error that is caused by the disturbance. Since the kinematic constraint does not allow heading correction when the joint axis is vertical, we extend the proposed method such that it improves accuracy and robustness when the joint is close to that singularity. We evaluate the method by simulations of a quick hand motion and study the effect of inaccurate sensor-to-segment (anatomical) calibration and joint constraint relaxations. As a main result, the proposed method is found to reduce the root-mean-square error of the joint angle from 25.8° to 2.6° in the presence of large magnetic disturbances.
AB - Inertial Measurement Units (IMUs) have become a widely used tool for rehabilitation and other application domains in which human motion is analyzed using an ambulatory or wearable setup. Since the magnetic field is inhomogeneous in indoor environments and in the proximity of ferromagnetic material, standard orientation estimation and joint angle calculation algorithms often lead to inaccurate or even completely wrong results. One approach to circumvent this is to exploit the kinematic constraint that is induced by mechanical hinge joints and also by approximate hinge joints such as the knee joint and the finger (interphalangeal) joints of the human body. We propose a quaternion-based method for joint angle measurement for approximate hinge joints moving through inhomogeneous magnetic fields. The method exploits the kinematic constraint to compensate the error that the magnetic disturbances induce in the IMU orientation estimates. This is achieved by realtime estimation and correction of the relative heading (azimuth) error that is caused by the disturbance. Since the kinematic constraint does not allow heading correction when the joint axis is vertical, we extend the proposed method such that it improves accuracy and robustness when the joint is close to that singularity. We evaluate the method by simulations of a quick hand motion and study the effect of inaccurate sensor-to-segment (anatomical) calibration and joint constraint relaxations. As a main result, the proposed method is found to reduce the root-mean-square error of the joint angle from 25.8° to 2.6° in the presence of large magnetic disturbances.
UR - http://www.scopus.com/inward/record.url?scp=85033992904&partnerID=8YFLogxK
U2 - 10.1109/icorr.2017.8009375
DO - 10.1109/icorr.2017.8009375
M3 - Conference contribution
T3 - IEEE International Conference on Rehabilitation Robotics
SP - 971
EP - 976
BT - 2017 International Conference on Rehabilitation Robotics (ICORR)
ER -