Abstract

In recent years, a significant interest has been growing in elevated temperature (ET) electrolytes for proton exchange membrane water electrolysis (PEMWE). In this study, the energy and exergy analysis developed for PEMWE has been extended to evaluate the performance of ET-PEMWE, with the model aiming to utilise the energy in the most efficient manner and also take into account potential heat losses. The latter is particularly important considering that heat losses become more pronounced with higher temperature differences. The model shows that the stack operates in autothermic mode over a considerable range of current density. Thus heating inputs to the stack and feed water become progressively unnecessary as polarization losses make up for these heating requirements. This also allows surplus heat to be utilised for secondary applications. The exergy efficiency for ET has been calculated to surpass that for low temperature (LT), with the maximum improvement reaching 3.8% points. Taking into account exergy favours higher temperature differences - a benefit which outweighs the fact that a greater quantity of thermal power is recovered in the LT system (due to higher polarization losses). This finding also shows the suitability of adopting exergy efficiency as the performance indicator for PEMWE systems.

ASJC Scopus Sachgebiete

Ziele für nachhaltige Entwicklung

Zitieren

Evaluation of the Efficiency of an Elevated Temperature Proton Exchange Membrane Water Electrolysis System. / Bonanno, Marco; Müller, Karsten; Bensmann, Boris et al.
in: Journal of the Electrochemical Society, Jahrgang 168, Nr. 9, 094504, 20.09.2021.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Bonanno M, Müller K, Bensmann B, Hanke-Rauschenbach R, Peach R, Thiele S. Evaluation of the Efficiency of an Elevated Temperature Proton Exchange Membrane Water Electrolysis System. Journal of the Electrochemical Society. 2021 Sep 20;168(9):094504. doi: 10.1149/1945-7111/ac2188
Bonanno, Marco ; Müller, Karsten ; Bensmann, Boris et al. / Evaluation of the Efficiency of an Elevated Temperature Proton Exchange Membrane Water Electrolysis System. in: Journal of the Electrochemical Society. 2021 ; Jahrgang 168, Nr. 9.
Download
@article{48887ea74bb1477f8d8a452b936c3850,
title = "Evaluation of the Efficiency of an Elevated Temperature Proton Exchange Membrane Water Electrolysis System",
abstract = "In recent years, a significant interest has been growing in elevated temperature (ET) electrolytes for proton exchange membrane water electrolysis (PEMWE). In this study, the energy and exergy analysis developed for PEMWE has been extended to evaluate the performance of ET-PEMWE, with the model aiming to utilise the energy in the most efficient manner and also take into account potential heat losses. The latter is particularly important considering that heat losses become more pronounced with higher temperature differences. The model shows that the stack operates in autothermic mode over a considerable range of current density. Thus heating inputs to the stack and feed water become progressively unnecessary as polarization losses make up for these heating requirements. This also allows surplus heat to be utilised for secondary applications. The exergy efficiency for ET has been calculated to surpass that for low temperature (LT), with the maximum improvement reaching 3.8% points. Taking into account exergy favours higher temperature differences - a benefit which outweighs the fact that a greater quantity of thermal power is recovered in the LT system (due to higher polarization losses). This finding also shows the suitability of adopting exergy efficiency as the performance indicator for PEMWE systems.",
author = "Marco Bonanno and Karsten M{\"u}ller and Boris Bensmann and Richard Hanke-Rauschenbach and Retha Peach and Simon Thiele",
year = "2021",
month = sep,
day = "20",
doi = "10.1149/1945-7111/ac2188",
language = "English",
volume = "168",
journal = "Journal of the Electrochemical Society",
issn = "0013-4651",
publisher = "Electrochemical Society, Inc.",
number = "9",

}

Download

TY - JOUR

T1 - Evaluation of the Efficiency of an Elevated Temperature Proton Exchange Membrane Water Electrolysis System

AU - Bonanno, Marco

AU - Müller, Karsten

AU - Bensmann, Boris

AU - Hanke-Rauschenbach, Richard

AU - Peach, Retha

AU - Thiele, Simon

PY - 2021/9/20

Y1 - 2021/9/20

N2 - In recent years, a significant interest has been growing in elevated temperature (ET) electrolytes for proton exchange membrane water electrolysis (PEMWE). In this study, the energy and exergy analysis developed for PEMWE has been extended to evaluate the performance of ET-PEMWE, with the model aiming to utilise the energy in the most efficient manner and also take into account potential heat losses. The latter is particularly important considering that heat losses become more pronounced with higher temperature differences. The model shows that the stack operates in autothermic mode over a considerable range of current density. Thus heating inputs to the stack and feed water become progressively unnecessary as polarization losses make up for these heating requirements. This also allows surplus heat to be utilised for secondary applications. The exergy efficiency for ET has been calculated to surpass that for low temperature (LT), with the maximum improvement reaching 3.8% points. Taking into account exergy favours higher temperature differences - a benefit which outweighs the fact that a greater quantity of thermal power is recovered in the LT system (due to higher polarization losses). This finding also shows the suitability of adopting exergy efficiency as the performance indicator for PEMWE systems.

AB - In recent years, a significant interest has been growing in elevated temperature (ET) electrolytes for proton exchange membrane water electrolysis (PEMWE). In this study, the energy and exergy analysis developed for PEMWE has been extended to evaluate the performance of ET-PEMWE, with the model aiming to utilise the energy in the most efficient manner and also take into account potential heat losses. The latter is particularly important considering that heat losses become more pronounced with higher temperature differences. The model shows that the stack operates in autothermic mode over a considerable range of current density. Thus heating inputs to the stack and feed water become progressively unnecessary as polarization losses make up for these heating requirements. This also allows surplus heat to be utilised for secondary applications. The exergy efficiency for ET has been calculated to surpass that for low temperature (LT), with the maximum improvement reaching 3.8% points. Taking into account exergy favours higher temperature differences - a benefit which outweighs the fact that a greater quantity of thermal power is recovered in the LT system (due to higher polarization losses). This finding also shows the suitability of adopting exergy efficiency as the performance indicator for PEMWE systems.

UR - http://www.scopus.com/inward/record.url?scp=85116379985&partnerID=8YFLogxK

U2 - 10.1149/1945-7111/ac2188

DO - 10.1149/1945-7111/ac2188

M3 - Article

AN - SCOPUS:85116379985

VL - 168

JO - Journal of the Electrochemical Society

JF - Journal of the Electrochemical Society

SN - 0013-4651

IS - 9

M1 - 094504

ER -

Von denselben Autoren