Erwärmungsverhalten dämmschichtbildender Brandschutzsysteme im Stahlbau: Numerische Simulationen unter Berücksichtigung des Aufschäumvorgangs

Publikation: Beitrag in nicht-wissenschaftlicher/populärwissenschaftlicher Zeitschrift/ZeitungBeitrag in Publikumszeitung/-zeitschriftTransfer

Autoren

  • Peter Schaumann
  • Florian Tabeling
  • Waldemar Weisheim

Organisationseinheiten

Forschungs-netzwerk anzeigen

Details

Titel in ÜbersetzungHeating behaviour of intumescent coatings in steel constructions - Advanced numerical simulations taking the foaming process into account
OriginalspracheDeutsch
Seiten646-651
Seitenumfang6
Band83
Ausgabenummer9
FachzeitschriftSTAHLBAU
PublikationsstatusVeröffentlicht - 1 Sept. 2014

Abstract

Intumescent coatings enable to sustain the attractiveness of filigree steel constructions and to ensure fire resistance at the same time. Since the high temperature behaviour of these fire protection systems is not known in detail yet, advanced numerical simulations by taking the foaming process of intumescent coatings into account are introduced in the present article. Hence, the heating behaviour is pointed out in detail to get a deeper understanding concerning the fire protection behaviour of intumescent coatings. For that reason, coated steel plates exposed to standard fire (ISO-834) are investigated. A validation of the developed numerical model is performed by comparing the calculated temperatures with own test results. For the first time, the opportunity is enabled to simulate and predict the high temperature behaviour of coated steel elements close to reality. This offers innovative possibilities to evaluate the steel temperature of construction elements individually in fire protection engineering.

ASJC Scopus Sachgebiete

Zitieren

Erwärmungsverhalten dämmschichtbildender Brandschutzsysteme im Stahlbau: Numerische Simulationen unter Berücksichtigung des Aufschäumvorgangs. / Schaumann, Peter; Tabeling, Florian; Weisheim, Waldemar.
in: STAHLBAU, Jahrgang 83, Nr. 9, 01.09.2014, S. 646-651.

Publikation: Beitrag in nicht-wissenschaftlicher/populärwissenschaftlicher Zeitschrift/ZeitungBeitrag in Publikumszeitung/-zeitschriftTransfer

Schaumann, Peter ; Tabeling, Florian ; Weisheim, Waldemar. / Erwärmungsverhalten dämmschichtbildender Brandschutzsysteme im Stahlbau : Numerische Simulationen unter Berücksichtigung des Aufschäumvorgangs. in: STAHLBAU. 2014 ; Jahrgang 83, Nr. 9. S. 646-651.
Download
@misc{37044c8be2dd4ef984fe0f1605c014dc,
title = "Erw{\"a}rmungsverhalten d{\"a}mmschichtbildender Brandschutzsysteme im Stahlbau: Numerische Simulationen unter Ber{\"u}cksichtigung des Aufsch{\"a}umvorgangs",
abstract = "Intumescent coatings enable to sustain the attractiveness of filigree steel constructions and to ensure fire resistance at the same time. Since the high temperature behaviour of these fire protection systems is not known in detail yet, advanced numerical simulations by taking the foaming process of intumescent coatings into account are introduced in the present article. Hence, the heating behaviour is pointed out in detail to get a deeper understanding concerning the fire protection behaviour of intumescent coatings. For that reason, coated steel plates exposed to standard fire (ISO-834) are investigated. A validation of the developed numerical model is performed by comparing the calculated temperatures with own test results. For the first time, the opportunity is enabled to simulate and predict the high temperature behaviour of coated steel elements close to reality. This offers innovative possibilities to evaluate the steel temperature of construction elements individually in fire protection engineering.",
author = "Peter Schaumann and Florian Tabeling and Waldemar Weisheim",
year = "2014",
month = sep,
day = "1",
doi = "10.1002/stab.201410187",
language = "Deutsch",
volume = "83",
pages = "646--651",
journal = "STAHLBAU",
issn = "0038-9145",
publisher = "Wiley-Blackwell",

}

Download

TY - GEN

T1 - Erwärmungsverhalten dämmschichtbildender Brandschutzsysteme im Stahlbau

T2 - Numerische Simulationen unter Berücksichtigung des Aufschäumvorgangs

AU - Schaumann, Peter

AU - Tabeling, Florian

AU - Weisheim, Waldemar

PY - 2014/9/1

Y1 - 2014/9/1

N2 - Intumescent coatings enable to sustain the attractiveness of filigree steel constructions and to ensure fire resistance at the same time. Since the high temperature behaviour of these fire protection systems is not known in detail yet, advanced numerical simulations by taking the foaming process of intumescent coatings into account are introduced in the present article. Hence, the heating behaviour is pointed out in detail to get a deeper understanding concerning the fire protection behaviour of intumescent coatings. For that reason, coated steel plates exposed to standard fire (ISO-834) are investigated. A validation of the developed numerical model is performed by comparing the calculated temperatures with own test results. For the first time, the opportunity is enabled to simulate and predict the high temperature behaviour of coated steel elements close to reality. This offers innovative possibilities to evaluate the steel temperature of construction elements individually in fire protection engineering.

AB - Intumescent coatings enable to sustain the attractiveness of filigree steel constructions and to ensure fire resistance at the same time. Since the high temperature behaviour of these fire protection systems is not known in detail yet, advanced numerical simulations by taking the foaming process of intumescent coatings into account are introduced in the present article. Hence, the heating behaviour is pointed out in detail to get a deeper understanding concerning the fire protection behaviour of intumescent coatings. For that reason, coated steel plates exposed to standard fire (ISO-834) are investigated. A validation of the developed numerical model is performed by comparing the calculated temperatures with own test results. For the first time, the opportunity is enabled to simulate and predict the high temperature behaviour of coated steel elements close to reality. This offers innovative possibilities to evaluate the steel temperature of construction elements individually in fire protection engineering.