Abstract
Different approaches are described for the characterisation of the low voltage mains network that is used for high-speed data transmission broadband over power line (BPL). Part 1 investigated the disturbance scenario of these BPL devices and importance will be given to develop a new measurement procedure in Comité Internationale Spécial des Perturbations Radioelectrotechnique (CISPR) to estimate the high-frequency characteristics of AC mains networks. The improvements of the measurement method that can also be applied to other wire-based telecommunication systems will also be presented. Part 2 shows the definitions and comparisons of different symmetry factors. The transfer of the results on the compliance test for BPL devices will also be depicted.
ASJC Scopus Sachgebiete
- Physik und Astronomie (insg.)
- Atom- und Molekularphysik sowie Optik
- Ingenieurwesen (insg.)
- Elektrotechnik und Elektronik
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
in: IET Science, Measurement and Technology, Jahrgang 2, Nr. 3, 05.2008, S. 154-159.
Publikation: Beitrag in Fachzeitschrift › Artikel › Forschung › Peer-Review
}
TY - JOUR
T1 - Electromagnetic compatibility analysis of unstructured mains networks for high-speed data transmission
T2 - Part 2
AU - Battermann, S.
AU - Garbe, H.
AU - Silva, F.
AU - Pous, M.
AU - Beauvois, V.
AU - Vantomme, K.
AU - Catrysse, J.
AU - Newbury, J.
AU - Degardin, V.
AU - Liénard, M.
AU - Degauque, P.
AU - Flintoft, I. D.
AU - Papatsoris, A. D.
AU - Welsh, D. W.
AU - Marvin, A. C.
PY - 2008/5
Y1 - 2008/5
N2 - Different approaches are described for the characterisation of the low voltage mains network that is used for high-speed data transmission broadband over power line (BPL). Part 1 investigated the disturbance scenario of these BPL devices and importance will be given to develop a new measurement procedure in Comité Internationale Spécial des Perturbations Radioelectrotechnique (CISPR) to estimate the high-frequency characteristics of AC mains networks. The improvements of the measurement method that can also be applied to other wire-based telecommunication systems will also be presented. Part 2 shows the definitions and comparisons of different symmetry factors. The transfer of the results on the compliance test for BPL devices will also be depicted.
AB - Different approaches are described for the characterisation of the low voltage mains network that is used for high-speed data transmission broadband over power line (BPL). Part 1 investigated the disturbance scenario of these BPL devices and importance will be given to develop a new measurement procedure in Comité Internationale Spécial des Perturbations Radioelectrotechnique (CISPR) to estimate the high-frequency characteristics of AC mains networks. The improvements of the measurement method that can also be applied to other wire-based telecommunication systems will also be presented. Part 2 shows the definitions and comparisons of different symmetry factors. The transfer of the results on the compliance test for BPL devices will also be depicted.
UR - http://www.scopus.com/inward/record.url?scp=40749121987&partnerID=8YFLogxK
U2 - 10.1049/iet-smt:20070056
DO - 10.1049/iet-smt:20070056
M3 - Article
AN - SCOPUS:40749121987
VL - 2
SP - 154
EP - 159
JO - IET Science, Measurement and Technology
JF - IET Science, Measurement and Technology
SN - 1751-8822
IS - 3
ER -