Electrochemical Degradation of Molecularly Imprinted Polymers for Future Applications of Inflammation Sensing in Cochlear Implants

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

  • Minh Hai Nguyen
  • Adrian Onken
  • Jan Sündermann
  • Madina Shamsuyeva
  • Pankaj Singla
  • Tom Depuydt
  • Marloes Peeters
  • Patrick Wagner
  • Konrad Bethmann
  • Julia Körner
  • Hans Josef Endres
  • Thomas Lenarz
  • Theodor Doll

Externe Organisationen

  • Medizinische Hochschule Hannover (MHH)
  • Fraunhofer-Institut für Toxikologie und Experimentelle Medizin (ITEM)
  • University of Manchester
  • KU Leuven
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)25223–25238
Seitenumfang16
FachzeitschriftACS Omega
Jahrgang9
Ausgabenummer23
Frühes Online-Datum24 Mai 2024
PublikationsstatusVeröffentlicht - 11 Juni 2024

Abstract

After cochlear implant (CI) insertion, there is a possibility of postoperative inflammation, which may involve proinflammatory markers such as interleukin-6. Detecting this inflammation promptly is crucial for administering anti-inflammatory drugs, if required. One potential method for detecting inflammation is using molecular imprinted polymers (MIPs). These MIPs, which can be deposited on the CI electrode, provide readout employing impedance measurements, a feature already available on the CI circuit. MIPs designed for this purpose should possess biocompatibility, conductivity, and degradability. The degradability is crucial because there is a limitation on the number of electrodes available, and once the inflammation sensor degrades after the acute inflammation period, it should remain usable as a regular electrode. In this work, conductive poly(3,4-ethylenedioxythiophene) polystyrenesulfonate-based MIPs were synthesized against biotin as a surrogate target marker. Specific biotin binding with MIPs was determined before and after degradation using electrochemical impedance spectroscopy (EIS) and compared with the control nonimprinted polymers (NIPs). Subsequently, MIPs were electrochemically degraded by EIS with different potentials, wherein a potential dependence was observed. With decreasing potential, fewer dissolved polymers and more monomer molecules were detected in the solution in which degradation took place. At a potential of 0.205 V a negligible amount of dissolved polymer in addition to the dissolved monomer molecules was measured, which can be defined as the limiting potential. Below this potential, only dissolved monomer molecules are obtained, which enables renal clearance. Biocompatibility testing revealed that both the polymer and the solution with dissolved monomer molecules do not exceed the ISO 10993-5 cytotoxicity threshold. Based on these findings, we have developed conductive, biocompatible, and controllably degradable MIPs capable of detecting biotin. This research work paves the way for the advancement of CIs, where inflammation can be detected using molecular imprinting technology without compromising the stability and biosafety of the product.

Zitieren

Electrochemical Degradation of Molecularly Imprinted Polymers for Future Applications of Inflammation Sensing in Cochlear Implants. / Nguyen, Minh Hai; Onken, Adrian; Sündermann, Jan et al.
in: ACS Omega, Jahrgang 9, Nr. 23, 11.06.2024, S. 25223–25238.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Nguyen, MH, Onken, A, Sündermann, J, Shamsuyeva, M, Singla, P, Depuydt, T, Peeters, M, Wagner, P, Bethmann, K, Körner, J, Endres, HJ, Lenarz, T & Doll, T 2024, 'Electrochemical Degradation of Molecularly Imprinted Polymers for Future Applications of Inflammation Sensing in Cochlear Implants', ACS Omega, Jg. 9, Nr. 23, S. 25223–25238. https://doi.org/10.1021/acsomega.4c02906
Nguyen, M. H., Onken, A., Sündermann, J., Shamsuyeva, M., Singla, P., Depuydt, T., Peeters, M., Wagner, P., Bethmann, K., Körner, J., Endres, H. J., Lenarz, T., & Doll, T. (2024). Electrochemical Degradation of Molecularly Imprinted Polymers for Future Applications of Inflammation Sensing in Cochlear Implants. ACS Omega, 9(23), 25223–25238. https://doi.org/10.1021/acsomega.4c02906
Nguyen MH, Onken A, Sündermann J, Shamsuyeva M, Singla P, Depuydt T et al. Electrochemical Degradation of Molecularly Imprinted Polymers for Future Applications of Inflammation Sensing in Cochlear Implants. ACS Omega. 2024 Jun 11;9(23):25223–25238. Epub 2024 Mai 24. doi: 10.1021/acsomega.4c02906
Nguyen, Minh Hai ; Onken, Adrian ; Sündermann, Jan et al. / Electrochemical Degradation of Molecularly Imprinted Polymers for Future Applications of Inflammation Sensing in Cochlear Implants. in: ACS Omega. 2024 ; Jahrgang 9, Nr. 23. S. 25223–25238.
Download
@article{0208442cfb7a4ff099bf819c394a992d,
title = "Electrochemical Degradation of Molecularly Imprinted Polymers for Future Applications of Inflammation Sensing in Cochlear Implants",
abstract = "After cochlear implant (CI) insertion, there is a possibility of postoperative inflammation, which may involve proinflammatory markers such as interleukin-6. Detecting this inflammation promptly is crucial for administering anti-inflammatory drugs, if required. One potential method for detecting inflammation is using molecular imprinted polymers (MIPs). These MIPs, which can be deposited on the CI electrode, provide readout employing impedance measurements, a feature already available on the CI circuit. MIPs designed for this purpose should possess biocompatibility, conductivity, and degradability. The degradability is crucial because there is a limitation on the number of electrodes available, and once the inflammation sensor degrades after the acute inflammation period, it should remain usable as a regular electrode. In this work, conductive poly(3,4-ethylenedioxythiophene) polystyrenesulfonate-based MIPs were synthesized against biotin as a surrogate target marker. Specific biotin binding with MIPs was determined before and after degradation using electrochemical impedance spectroscopy (EIS) and compared with the control nonimprinted polymers (NIPs). Subsequently, MIPs were electrochemically degraded by EIS with different potentials, wherein a potential dependence was observed. With decreasing potential, fewer dissolved polymers and more monomer molecules were detected in the solution in which degradation took place. At a potential of 0.205 V a negligible amount of dissolved polymer in addition to the dissolved monomer molecules was measured, which can be defined as the limiting potential. Below this potential, only dissolved monomer molecules are obtained, which enables renal clearance. Biocompatibility testing revealed that both the polymer and the solution with dissolved monomer molecules do not exceed the ISO 10993-5 cytotoxicity threshold. Based on these findings, we have developed conductive, biocompatible, and controllably degradable MIPs capable of detecting biotin. This research work paves the way for the advancement of CIs, where inflammation can be detected using molecular imprinting technology without compromising the stability and biosafety of the product.",
author = "Nguyen, {Minh Hai} and Adrian Onken and Jan S{\"u}ndermann and Madina Shamsuyeva and Pankaj Singla and Tom Depuydt and Marloes Peeters and Patrick Wagner and Konrad Bethmann and Julia K{\"o}rner and Endres, {Hans Josef} and Thomas Lenarz and Theodor Doll",
note = "Publisher Copyright: {\textcopyright} 2024 The Authors. Published by American Chemical Society",
year = "2024",
month = jun,
day = "11",
doi = "10.1021/acsomega.4c02906",
language = "English",
volume = "9",
pages = "25223–25238",
number = "23",

}

Download

TY - JOUR

T1 - Electrochemical Degradation of Molecularly Imprinted Polymers for Future Applications of Inflammation Sensing in Cochlear Implants

AU - Nguyen, Minh Hai

AU - Onken, Adrian

AU - Sündermann, Jan

AU - Shamsuyeva, Madina

AU - Singla, Pankaj

AU - Depuydt, Tom

AU - Peeters, Marloes

AU - Wagner, Patrick

AU - Bethmann, Konrad

AU - Körner, Julia

AU - Endres, Hans Josef

AU - Lenarz, Thomas

AU - Doll, Theodor

N1 - Publisher Copyright: © 2024 The Authors. Published by American Chemical Society

PY - 2024/6/11

Y1 - 2024/6/11

N2 - After cochlear implant (CI) insertion, there is a possibility of postoperative inflammation, which may involve proinflammatory markers such as interleukin-6. Detecting this inflammation promptly is crucial for administering anti-inflammatory drugs, if required. One potential method for detecting inflammation is using molecular imprinted polymers (MIPs). These MIPs, which can be deposited on the CI electrode, provide readout employing impedance measurements, a feature already available on the CI circuit. MIPs designed for this purpose should possess biocompatibility, conductivity, and degradability. The degradability is crucial because there is a limitation on the number of electrodes available, and once the inflammation sensor degrades after the acute inflammation period, it should remain usable as a regular electrode. In this work, conductive poly(3,4-ethylenedioxythiophene) polystyrenesulfonate-based MIPs were synthesized against biotin as a surrogate target marker. Specific biotin binding with MIPs was determined before and after degradation using electrochemical impedance spectroscopy (EIS) and compared with the control nonimprinted polymers (NIPs). Subsequently, MIPs were electrochemically degraded by EIS with different potentials, wherein a potential dependence was observed. With decreasing potential, fewer dissolved polymers and more monomer molecules were detected in the solution in which degradation took place. At a potential of 0.205 V a negligible amount of dissolved polymer in addition to the dissolved monomer molecules was measured, which can be defined as the limiting potential. Below this potential, only dissolved monomer molecules are obtained, which enables renal clearance. Biocompatibility testing revealed that both the polymer and the solution with dissolved monomer molecules do not exceed the ISO 10993-5 cytotoxicity threshold. Based on these findings, we have developed conductive, biocompatible, and controllably degradable MIPs capable of detecting biotin. This research work paves the way for the advancement of CIs, where inflammation can be detected using molecular imprinting technology without compromising the stability and biosafety of the product.

AB - After cochlear implant (CI) insertion, there is a possibility of postoperative inflammation, which may involve proinflammatory markers such as interleukin-6. Detecting this inflammation promptly is crucial for administering anti-inflammatory drugs, if required. One potential method for detecting inflammation is using molecular imprinted polymers (MIPs). These MIPs, which can be deposited on the CI electrode, provide readout employing impedance measurements, a feature already available on the CI circuit. MIPs designed for this purpose should possess biocompatibility, conductivity, and degradability. The degradability is crucial because there is a limitation on the number of electrodes available, and once the inflammation sensor degrades after the acute inflammation period, it should remain usable as a regular electrode. In this work, conductive poly(3,4-ethylenedioxythiophene) polystyrenesulfonate-based MIPs were synthesized against biotin as a surrogate target marker. Specific biotin binding with MIPs was determined before and after degradation using electrochemical impedance spectroscopy (EIS) and compared with the control nonimprinted polymers (NIPs). Subsequently, MIPs were electrochemically degraded by EIS with different potentials, wherein a potential dependence was observed. With decreasing potential, fewer dissolved polymers and more monomer molecules were detected in the solution in which degradation took place. At a potential of 0.205 V a negligible amount of dissolved polymer in addition to the dissolved monomer molecules was measured, which can be defined as the limiting potential. Below this potential, only dissolved monomer molecules are obtained, which enables renal clearance. Biocompatibility testing revealed that both the polymer and the solution with dissolved monomer molecules do not exceed the ISO 10993-5 cytotoxicity threshold. Based on these findings, we have developed conductive, biocompatible, and controllably degradable MIPs capable of detecting biotin. This research work paves the way for the advancement of CIs, where inflammation can be detected using molecular imprinting technology without compromising the stability and biosafety of the product.

UR - http://www.scopus.com/inward/record.url?scp=85194229952&partnerID=8YFLogxK

U2 - 10.1021/acsomega.4c02906

DO - 10.1021/acsomega.4c02906

M3 - Article

AN - SCOPUS:85194229952

VL - 9

SP - 25223

EP - 25238

JO - ACS Omega

JF - ACS Omega

IS - 23

ER -