Abstract
Partial discharge (PD) measurements in power transformers are a well-known tool for condition assessment of the insulation system. For this purpose, the conventional method according to textbf IEC 60270 is applied; however, the UHF PD technique, which is based on the propagation of electromagnetic waves due to a PD fault in ultrahigh frequency (UHF) range, has advantages, e.g. the possibility of online application due to improved immunity against external noises. In this contribution, the effects of the UHF probe surroundings at the installed position as well as the waveforms of the captured UHF pulses in time and frequency domain are investigated. The effect of the transformer tank on the UHF pulses is studied by measuring the scattering parameters of the probes in regards to their reflection and transmission coefficients in a transformer tank model. Moreover, two PD types, corona and surface discharges, are analyzed concerning their propagated PD pulses in time and frequency domain.
ASJC Scopus Sachgebiete
- Ingenieurwesen (insg.)
- Elektrotechnik und Elektronik
- Werkstoffwissenschaften (insg.)
- Elektronische, optische und magnetische Materialien
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
2018 IEEE 2nd International Conference on Dielectrics, ICD 2018. Institute of Electrical and Electronics Engineers Inc., 2018. 8514737.
Publikation: Beitrag in Buch/Bericht/Sammelwerk/Konferenzband › Aufsatz in Konferenzband › Forschung › Peer-Review
}
TY - GEN
T1 - Effect of Surroundings of UHF Partial Discharge Probes on the Captured Pulses in Power Transformers
AU - Azirani, Mohammad Akbari
AU - Werle, Peter
AU - Akbari, Asghar
N1 - Funding Information: ACKNOWLEDGMENT The authors would like to express their gratitude towards the ABB AG, Germany for the support of this research. Publisher Copyright: © 2018 IEEE. Copyright: Copyright 2018 Elsevier B.V., All rights reserved.
PY - 2018/9/19
Y1 - 2018/9/19
N2 - Partial discharge (PD) measurements in power transformers are a well-known tool for condition assessment of the insulation system. For this purpose, the conventional method according to textbf IEC 60270 is applied; however, the UHF PD technique, which is based on the propagation of electromagnetic waves due to a PD fault in ultrahigh frequency (UHF) range, has advantages, e.g. the possibility of online application due to improved immunity against external noises. In this contribution, the effects of the UHF probe surroundings at the installed position as well as the waveforms of the captured UHF pulses in time and frequency domain are investigated. The effect of the transformer tank on the UHF pulses is studied by measuring the scattering parameters of the probes in regards to their reflection and transmission coefficients in a transformer tank model. Moreover, two PD types, corona and surface discharges, are analyzed concerning their propagated PD pulses in time and frequency domain.
AB - Partial discharge (PD) measurements in power transformers are a well-known tool for condition assessment of the insulation system. For this purpose, the conventional method according to textbf IEC 60270 is applied; however, the UHF PD technique, which is based on the propagation of electromagnetic waves due to a PD fault in ultrahigh frequency (UHF) range, has advantages, e.g. the possibility of online application due to improved immunity against external noises. In this contribution, the effects of the UHF probe surroundings at the installed position as well as the waveforms of the captured UHF pulses in time and frequency domain are investigated. The effect of the transformer tank on the UHF pulses is studied by measuring the scattering parameters of the probes in regards to their reflection and transmission coefficients in a transformer tank model. Moreover, two PD types, corona and surface discharges, are analyzed concerning their propagated PD pulses in time and frequency domain.
KW - IEC 60270
KW - Partial Discharge
KW - Power Transformers
KW - UHF Measurement Technique
KW - UHF Probes
UR - http://www.scopus.com/inward/record.url?scp=85056593690&partnerID=8YFLogxK
U2 - 10.1109/ICD.2018.8514737
DO - 10.1109/ICD.2018.8514737
M3 - Conference contribution
AN - SCOPUS:85056593690
BT - 2018 IEEE 2nd International Conference on Dielectrics, ICD 2018
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2nd IEEE International Conference on Dielectrics, ICD 2018
Y2 - 1 July 2018 through 5 July 2018
ER -