Effect of hydrogen concentration in conventional and IAD coatings on the absorption and laser-induced damage at 10.6 um

Publikation: KonferenzbeitragPaperForschungPeer-Review

Autorschaft

  • Manfred Rahe
  • Detlev Ristau
  • Holger Schmidt

Externe Organisationen

  • Laser Zentrum Hannover e.V. (LZH)
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten335-348
Seitenumfang14
PublikationsstatusVeröffentlicht - 24 Juni 1993
Extern publiziertJa
Veranstaltung24th Annual Boulder Damage Symposium Laser-Induced Damage in Optical Materials: 1992 - Boulder, CO, USA
Dauer: 28 Okt. 199230 Okt. 1992

Konferenz

Konferenz24th Annual Boulder Damage Symposium Laser-Induced Damage in Optical Materials: 1992
OrtBoulder, CO, USA
Zeitraum28 Okt. 199230 Okt. 1992

Abstract

In this paper, data of single layers of YbF3, BaF2, YF 3, and NaF and multilayer coatings produced by conventional thermal evaporation (boat, e-beam) and ion assisted deposition (IAD) are compared. Hydrogen concentration depth profiling was performed using nuclear reaction analysis based on the reaction 1H(15N, αγ)12C. Absorption was measured with the aid of a laser calorimeter and a cw CO2 laser. A computer-controlled test facility with a TEA CO2 laser was used for determining the 1-on-1 damage thresholds of the coatings. The results point out that the absorption and damage behavior of coatings for the CO2 laser wavelength are related to the total amount of species containing hydrogen. Most of the IAD coatings exhibit a lower hydrogen contamination than conventional thin films.

ASJC Scopus Sachgebiete

Zitieren

Effect of hydrogen concentration in conventional and IAD coatings on the absorption and laser-induced damage at 10.6 um. / Rahe, Manfred; Ristau, Detlev; Schmidt, Holger.
1993. 335-348 Beitrag in 24th Annual Boulder Damage Symposium Laser-Induced Damage in Optical Materials: 1992, Boulder, CO, USA.

Publikation: KonferenzbeitragPaperForschungPeer-Review

Rahe, M, Ristau, D & Schmidt, H 1993, 'Effect of hydrogen concentration in conventional and IAD coatings on the absorption and laser-induced damage at 10.6 um', Beitrag in 24th Annual Boulder Damage Symposium Laser-Induced Damage in Optical Materials: 1992, Boulder, CO, USA, 28 Okt. 1992 - 30 Okt. 1992 S. 335-348. https://doi.org/10.1117/12.147408
Rahe, M., Ristau, D., & Schmidt, H. (1993). Effect of hydrogen concentration in conventional and IAD coatings on the absorption and laser-induced damage at 10.6 um. 335-348. Beitrag in 24th Annual Boulder Damage Symposium Laser-Induced Damage in Optical Materials: 1992, Boulder, CO, USA. https://doi.org/10.1117/12.147408
Rahe M, Ristau D, Schmidt H. Effect of hydrogen concentration in conventional and IAD coatings on the absorption and laser-induced damage at 10.6 um. 1993. Beitrag in 24th Annual Boulder Damage Symposium Laser-Induced Damage in Optical Materials: 1992, Boulder, CO, USA. doi: 10.1117/12.147408
Rahe, Manfred ; Ristau, Detlev ; Schmidt, Holger. / Effect of hydrogen concentration in conventional and IAD coatings on the absorption and laser-induced damage at 10.6 um. Beitrag in 24th Annual Boulder Damage Symposium Laser-Induced Damage in Optical Materials: 1992, Boulder, CO, USA.14 S.
Download
@conference{3c9b736554be414f89866b2eb77e9b21,
title = "Effect of hydrogen concentration in conventional and IAD coatings on the absorption and laser-induced damage at 10.6 um",
abstract = "In this paper, data of single layers of YbF3, BaF2, YF 3, and NaF and multilayer coatings produced by conventional thermal evaporation (boat, e-beam) and ion assisted deposition (IAD) are compared. Hydrogen concentration depth profiling was performed using nuclear reaction analysis based on the reaction 1H(15N, αγ)12C. Absorption was measured with the aid of a laser calorimeter and a cw CO2 laser. A computer-controlled test facility with a TEA CO2 laser was used for determining the 1-on-1 damage thresholds of the coatings. The results point out that the absorption and damage behavior of coatings for the CO2 laser wavelength are related to the total amount of species containing hydrogen. Most of the IAD coatings exhibit a lower hydrogen contamination than conventional thin films.",
author = "Manfred Rahe and Detlev Ristau and Holger Schmidt",
year = "1993",
month = jun,
day = "24",
doi = "10.1117/12.147408",
language = "English",
pages = "335--348",
note = "24th Annual Boulder Damage Symposium Laser-Induced Damage in Optical Materials: 1992 ; Conference date: 28-10-1992 Through 30-10-1992",

}

Download

TY - CONF

T1 - Effect of hydrogen concentration in conventional and IAD coatings on the absorption and laser-induced damage at 10.6 um

AU - Rahe, Manfred

AU - Ristau, Detlev

AU - Schmidt, Holger

PY - 1993/6/24

Y1 - 1993/6/24

N2 - In this paper, data of single layers of YbF3, BaF2, YF 3, and NaF and multilayer coatings produced by conventional thermal evaporation (boat, e-beam) and ion assisted deposition (IAD) are compared. Hydrogen concentration depth profiling was performed using nuclear reaction analysis based on the reaction 1H(15N, αγ)12C. Absorption was measured with the aid of a laser calorimeter and a cw CO2 laser. A computer-controlled test facility with a TEA CO2 laser was used for determining the 1-on-1 damage thresholds of the coatings. The results point out that the absorption and damage behavior of coatings for the CO2 laser wavelength are related to the total amount of species containing hydrogen. Most of the IAD coatings exhibit a lower hydrogen contamination than conventional thin films.

AB - In this paper, data of single layers of YbF3, BaF2, YF 3, and NaF and multilayer coatings produced by conventional thermal evaporation (boat, e-beam) and ion assisted deposition (IAD) are compared. Hydrogen concentration depth profiling was performed using nuclear reaction analysis based on the reaction 1H(15N, αγ)12C. Absorption was measured with the aid of a laser calorimeter and a cw CO2 laser. A computer-controlled test facility with a TEA CO2 laser was used for determining the 1-on-1 damage thresholds of the coatings. The results point out that the absorption and damage behavior of coatings for the CO2 laser wavelength are related to the total amount of species containing hydrogen. Most of the IAD coatings exhibit a lower hydrogen contamination than conventional thin films.

UR - http://www.scopus.com/inward/record.url?scp=0027866092&partnerID=8YFLogxK

U2 - 10.1117/12.147408

DO - 10.1117/12.147408

M3 - Paper

AN - SCOPUS:0027866092

SP - 335

EP - 348

T2 - 24th Annual Boulder Damage Symposium Laser-Induced Damage in Optical Materials: 1992

Y2 - 28 October 1992 through 30 October 1992

ER -