Details
Originalsprache | Englisch |
---|---|
Seiten (von - bis) | 1137-1172 |
Seitenumfang | 36 |
Fachzeitschrift | Journal of earthquake engineering |
Jahrgang | 23 |
Ausgabenummer | 7 |
Publikationsstatus | Veröffentlicht - 9 Aug. 2019 |
Extern publiziert | Ja |
Abstract
The effectiveness of the multi-mode control of seismically excited building installed with distributed multiple tuned mass dampers (d-MTMDs) is investigated by comparing dynamic response with the other controllers, such as passive friction dampers, semi-active dampers, single tuned mass damper (STMD), and multiple tuned mass dampers (MTMDs-all.top), both installed at the top of the building, and arbitrarily distributed MTMDs (ad-MTMDs). It is concluded that the d-MTMDs exhibit improved performance as compared with the STMD, MTMDs-all.top, and ad-MTMDs. The d-MTMDs are also convenient to install owing to the reduced space requirements, being placed at various floors.
ASJC Scopus Sachgebiete
- Ingenieurwesen (insg.)
- Tief- und Ingenieurbau
- Ingenieurwesen (insg.)
- Bauwesen
- Erdkunde und Planetologie (insg.)
- Geotechnik und Ingenieurgeologie
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
in: Journal of earthquake engineering, Jahrgang 23, Nr. 7, 09.08.2019, S. 1137-1172.
Publikation: Beitrag in Fachzeitschrift › Artikel › Forschung › Peer-Review
}
TY - JOUR
T1 - Distributed Tuned Mass Dampers for Multi-Mode Control of Benchmark Building under Seismic Excitations
AU - Elias, Said
AU - Matsagar, Vasant
AU - Datta, T. K.
N1 - Publisher Copyright: © 2017, © 2017 Taylor & Francis Group, LLC.
PY - 2019/8/9
Y1 - 2019/8/9
N2 - The effectiveness of the multi-mode control of seismically excited building installed with distributed multiple tuned mass dampers (d-MTMDs) is investigated by comparing dynamic response with the other controllers, such as passive friction dampers, semi-active dampers, single tuned mass damper (STMD), and multiple tuned mass dampers (MTMDs-all.top), both installed at the top of the building, and arbitrarily distributed MTMDs (ad-MTMDs). It is concluded that the d-MTMDs exhibit improved performance as compared with the STMD, MTMDs-all.top, and ad-MTMDs. The d-MTMDs are also convenient to install owing to the reduced space requirements, being placed at various floors.
AB - The effectiveness of the multi-mode control of seismically excited building installed with distributed multiple tuned mass dampers (d-MTMDs) is investigated by comparing dynamic response with the other controllers, such as passive friction dampers, semi-active dampers, single tuned mass damper (STMD), and multiple tuned mass dampers (MTMDs-all.top), both installed at the top of the building, and arbitrarily distributed MTMDs (ad-MTMDs). It is concluded that the d-MTMDs exhibit improved performance as compared with the STMD, MTMDs-all.top, and ad-MTMDs. The d-MTMDs are also convenient to install owing to the reduced space requirements, being placed at various floors.
KW - Benchmark Building
KW - d-MTMDs
KW - Modal Frequency/Shape
KW - Seismic
KW - Single Tuned Mass Damper
KW - TMDs
UR - http://www.scopus.com/inward/record.url?scp=85029713010&partnerID=8YFLogxK
U2 - 10.1080/13632469.2017.1351407
DO - 10.1080/13632469.2017.1351407
M3 - Article
AN - SCOPUS:85029713010
VL - 23
SP - 1137
EP - 1172
JO - Journal of earthquake engineering
JF - Journal of earthquake engineering
SN - 1363-2469
IS - 7
ER -