Details
Originalsprache | Englisch |
---|---|
Titel des Sammelwerks | IEEE Energy Conversion Congress and Exposition |
Untertitel | Energy Conversion Innovation for a Clean Energy Future, ECCE 2011, Proceedings |
Seiten | 2993-2999 |
Seitenumfang | 7 |
Publikationsstatus | Veröffentlicht - 2011 |
Veranstaltung | 3rd Annual IEEE Energy Conversion Congress and Exposition, ECCE 2011 - Phoenix, AZ, USA / Vereinigte Staaten Dauer: 17 Sept. 2011 → 22 Sept. 2011 |
Publikationsreihe
Name | IEEE Energy Conversion Congress and Exposition: Energy Conversion Innovation for a Clean Energy Future, ECCE 2011, Proceedings |
---|
Abstract
Digital technology incorporated into the gate drive unit of HV-IGBTs allows new features, like automatic optimization of the gate current waveforms for achieving certain properties of the switching transients, or automatic adaptation to the operating conditions. This paper presents a digital gate unit with on-line measurement of the IGBT's switching waveforms. Based on this, a robust control algorithm is developed to adapt the gate current waveforms to the desired switching behavior, irrespective of the operating conditions. The algorithm is implemented in a Field-Programmable Gate Array (FPGA) on the gate unit and experimentally verified for several optimization objectives using 3.3 kV and 1200 A IGBTs.
ASJC Scopus Sachgebiete
- Energie (insg.)
- Energieanlagenbau und Kraftwerkstechnik
- Energie (insg.)
- Erneuerbare Energien, Nachhaltigkeit und Umwelt
Ziele für nachhaltige Entwicklung
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
IEEE Energy Conversion Congress and Exposition: Energy Conversion Innovation for a Clean Energy Future, ECCE 2011, Proceedings. 2011. S. 2993-2999 6064172 (IEEE Energy Conversion Congress and Exposition: Energy Conversion Innovation for a Clean Energy Future, ECCE 2011, Proceedings).
Publikation: Beitrag in Buch/Bericht/Sammelwerk/Konferenzband › Aufsatz in Konferenzband › Forschung › Peer-Review
}
TY - GEN
T1 - Digital adaptive driving strategies for high-voltage IGBTs
AU - Dang, Lan
AU - Kuhn, Harald
AU - Mertens, Axel
PY - 2011
Y1 - 2011
N2 - Digital technology incorporated into the gate drive unit of HV-IGBTs allows new features, like automatic optimization of the gate current waveforms for achieving certain properties of the switching transients, or automatic adaptation to the operating conditions. This paper presents a digital gate unit with on-line measurement of the IGBT's switching waveforms. Based on this, a robust control algorithm is developed to adapt the gate current waveforms to the desired switching behavior, irrespective of the operating conditions. The algorithm is implemented in a Field-Programmable Gate Array (FPGA) on the gate unit and experimentally verified for several optimization objectives using 3.3 kV and 1200 A IGBTs.
AB - Digital technology incorporated into the gate drive unit of HV-IGBTs allows new features, like automatic optimization of the gate current waveforms for achieving certain properties of the switching transients, or automatic adaptation to the operating conditions. This paper presents a digital gate unit with on-line measurement of the IGBT's switching waveforms. Based on this, a robust control algorithm is developed to adapt the gate current waveforms to the desired switching behavior, irrespective of the operating conditions. The algorithm is implemented in a Field-Programmable Gate Array (FPGA) on the gate unit and experimentally verified for several optimization objectives using 3.3 kV and 1200 A IGBTs.
UR - http://www.scopus.com/inward/record.url?scp=81855217355&partnerID=8YFLogxK
U2 - 10.1109/ECCE.2011.6064172
DO - 10.1109/ECCE.2011.6064172
M3 - Conference contribution
AN - SCOPUS:81855217355
SN - 9781457705427
T3 - IEEE Energy Conversion Congress and Exposition: Energy Conversion Innovation for a Clean Energy Future, ECCE 2011, Proceedings
SP - 2993
EP - 2999
BT - IEEE Energy Conversion Congress and Exposition
T2 - 3rd Annual IEEE Energy Conversion Congress and Exposition, ECCE 2011
Y2 - 17 September 2011 through 22 September 2011
ER -