Abstract

This paper presents the development of a micro-positioning system for the increase of operation accuracy of machine tools. A highly dynamic piezo-actuated micropump coupled with a hydraulic cylinder transforms small strokes of the piezoelectric actuator into a continuous piston movement. Fast-switching active valves direct the volume flow. Crucial for the functionality of the pump module is the sealing function of the membrane to isolate the piezoelectric actuator unit against high pressure fluid. Therefore, the requirements for foil membrane selection are investigated by means of a developed test bench. It is demonstrated that a successful test of foil membrane materials provides a closer insight into the entire valve characteristics.

ASJC Scopus Sachgebiete

Zitieren

Development of an advanced micro-positioning system for increasing operation accuracy: Consideration of high pressure sealing. / Pluemer, Sabrina; Voges-Schwieger, Kathrin; Denkena, Berend et al.
in: Production Engineering, Jahrgang 6, Nr. 2, 17.01.2012, S. 213-218.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Pluemer, S, Voges-Schwieger, K, Denkena, B & Behrens, BA 2012, 'Development of an advanced micro-positioning system for increasing operation accuracy: Consideration of high pressure sealing', Production Engineering, Jg. 6, Nr. 2, S. 213-218. https://doi.org/10.1007/s11740-012-0361-2
Pluemer, S., Voges-Schwieger, K., Denkena, B., & Behrens, B. A. (2012). Development of an advanced micro-positioning system for increasing operation accuracy: Consideration of high pressure sealing. Production Engineering, 6(2), 213-218. https://doi.org/10.1007/s11740-012-0361-2
Pluemer S, Voges-Schwieger K, Denkena B, Behrens BA. Development of an advanced micro-positioning system for increasing operation accuracy: Consideration of high pressure sealing. Production Engineering. 2012 Jan 17;6(2):213-218. doi: 10.1007/s11740-012-0361-2
Pluemer, Sabrina ; Voges-Schwieger, Kathrin ; Denkena, Berend et al. / Development of an advanced micro-positioning system for increasing operation accuracy : Consideration of high pressure sealing. in: Production Engineering. 2012 ; Jahrgang 6, Nr. 2. S. 213-218.
Download
@article{c4d2ffd3f36a42d2b56de2c005c3554a,
title = "Development of an advanced micro-positioning system for increasing operation accuracy: Consideration of high pressure sealing",
abstract = "This paper presents the development of a micro-positioning system for the increase of operation accuracy of machine tools. A highly dynamic piezo-actuated micropump coupled with a hydraulic cylinder transforms small strokes of the piezoelectric actuator into a continuous piston movement. Fast-switching active valves direct the volume flow. Crucial for the functionality of the pump module is the sealing function of the membrane to isolate the piezoelectric actuator unit against high pressure fluid. Therefore, the requirements for foil membrane selection are investigated by means of a developed test bench. It is demonstrated that a successful test of foil membrane materials provides a closer insight into the entire valve characteristics.",
keywords = "Foil membrane test bench, Micro-positioning system, Piezoelectric actuator",
author = "Sabrina Pluemer and Kathrin Voges-Schwieger and Berend Denkena and Behrens, {Bernd Arno}",
note = "Funding information: Acknowledgments The authors thank the German Research Foundation (DFG) for funding this research concerning a piezo-hydraulic micro-positioning system for high loads (DE 447/25).",
year = "2012",
month = jan,
day = "17",
doi = "10.1007/s11740-012-0361-2",
language = "English",
volume = "6",
pages = "213--218",
number = "2",

}

Download

TY - JOUR

T1 - Development of an advanced micro-positioning system for increasing operation accuracy

T2 - Consideration of high pressure sealing

AU - Pluemer, Sabrina

AU - Voges-Schwieger, Kathrin

AU - Denkena, Berend

AU - Behrens, Bernd Arno

N1 - Funding information: Acknowledgments The authors thank the German Research Foundation (DFG) for funding this research concerning a piezo-hydraulic micro-positioning system for high loads (DE 447/25).

PY - 2012/1/17

Y1 - 2012/1/17

N2 - This paper presents the development of a micro-positioning system for the increase of operation accuracy of machine tools. A highly dynamic piezo-actuated micropump coupled with a hydraulic cylinder transforms small strokes of the piezoelectric actuator into a continuous piston movement. Fast-switching active valves direct the volume flow. Crucial for the functionality of the pump module is the sealing function of the membrane to isolate the piezoelectric actuator unit against high pressure fluid. Therefore, the requirements for foil membrane selection are investigated by means of a developed test bench. It is demonstrated that a successful test of foil membrane materials provides a closer insight into the entire valve characteristics.

AB - This paper presents the development of a micro-positioning system for the increase of operation accuracy of machine tools. A highly dynamic piezo-actuated micropump coupled with a hydraulic cylinder transforms small strokes of the piezoelectric actuator into a continuous piston movement. Fast-switching active valves direct the volume flow. Crucial for the functionality of the pump module is the sealing function of the membrane to isolate the piezoelectric actuator unit against high pressure fluid. Therefore, the requirements for foil membrane selection are investigated by means of a developed test bench. It is demonstrated that a successful test of foil membrane materials provides a closer insight into the entire valve characteristics.

KW - Foil membrane test bench

KW - Micro-positioning system

KW - Piezoelectric actuator

UR - http://www.scopus.com/inward/record.url?scp=84859157952&partnerID=8YFLogxK

U2 - 10.1007/s11740-012-0361-2

DO - 10.1007/s11740-012-0361-2

M3 - Article

AN - SCOPUS:84859157952

VL - 6

SP - 213

EP - 218

JO - Production Engineering

JF - Production Engineering

SN - 0944-6524

IS - 2

ER -