Details
Originalsprache | Englisch |
---|---|
Seiten (von - bis) | 905-920 |
Seitenumfang | 16 |
Fachzeitschrift | European journal of mineralogy |
Jahrgang | 7 |
Ausgabenummer | 4 |
Publikationsstatus | Veröffentlicht - 1995 |
Abstract
The solubility of water in melts of albitic (Ab: NaAlSi3O8) and orthoclasic (Or: KAlSi3O8) compositions was re-investigated at T = 1100°C and at pressures between 0.5 and 5.0 kbar. The influence of starting materials, sample preparation, run procedure and analytical methods on the solubility data was investigated systematically. Different analytical techniques (Karl-Fischer titration (KFT), near-infrared spectroscopy (NIR), 105°C weight loss and weight loss on ignition) give consistent results under certain conditions, whereas water-specific methods (KFT and NIR) have a higher precision. -from Author
ASJC Scopus Sachgebiete
- Erdkunde und Planetologie (insg.)
- Geochemie und Petrologie
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
in: European journal of mineralogy, Jahrgang 7, Nr. 4, 1995, S. 905-920.
Publikation: Beitrag in Fachzeitschrift › Artikel › Forschung › Peer-Review
}
TY - JOUR
T1 - Determination of water solubilities in high-viscosity melts
T2 - an experimental study on NaAlSi3O8 and KAlSi3O8 melts
AU - Behrens, H.
PY - 1995
Y1 - 1995
N2 - The solubility of water in melts of albitic (Ab: NaAlSi3O8) and orthoclasic (Or: KAlSi3O8) compositions was re-investigated at T = 1100°C and at pressures between 0.5 and 5.0 kbar. The influence of starting materials, sample preparation, run procedure and analytical methods on the solubility data was investigated systematically. Different analytical techniques (Karl-Fischer titration (KFT), near-infrared spectroscopy (NIR), 105°C weight loss and weight loss on ignition) give consistent results under certain conditions, whereas water-specific methods (KFT and NIR) have a higher precision. -from Author
AB - The solubility of water in melts of albitic (Ab: NaAlSi3O8) and orthoclasic (Or: KAlSi3O8) compositions was re-investigated at T = 1100°C and at pressures between 0.5 and 5.0 kbar. The influence of starting materials, sample preparation, run procedure and analytical methods on the solubility data was investigated systematically. Different analytical techniques (Karl-Fischer titration (KFT), near-infrared spectroscopy (NIR), 105°C weight loss and weight loss on ignition) give consistent results under certain conditions, whereas water-specific methods (KFT and NIR) have a higher precision. -from Author
UR - http://www.scopus.com/inward/record.url?scp=0028830442&partnerID=8YFLogxK
U2 - 10.1127/ejm/7/4/0905
DO - 10.1127/ejm/7/4/0905
M3 - Article
AN - SCOPUS:0028830442
VL - 7
SP - 905
EP - 920
JO - European journal of mineralogy
JF - European journal of mineralogy
SN - 0935-1221
IS - 4
ER -