Abstract
The paper focuses on simulating the transfer function of power transformer winding sections based on design information. The calculation method has been investigated and discussed. The simulation of windings through multi conductor transmission line method has been performed for an actual distribution transformer in the laboratory using the design information. With this information the transfer function of the transformer winding sections has been calculated. Additionally some measurements on the distribution transformer have been done in three test platforms with different measurement devices in order to compare the methods for evaluating the transfer function of this transformer. The simulated transfer function has been adapted by comparison between the simulation and measurement results. As a result of the comparison, a deviation factor could be defined and the most sensitive parameters of the simulation methods could be identified. The difference between simulation and measurement leads to knowledge about the required measurements on a transformer as basis for the simulation of the transfer function of the transformer winding sections.
ASJC Scopus Sachgebiete
- Werkstoffwissenschaften (insg.)
- Elektronische, optische und magnetische Materialien
- Ingenieurwesen (insg.)
- Elektrotechnik und Elektronik
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
2016 IEEE Conference on Electrical Insulation and Dielectric Phenomena, CEIDP 2016. Institute of Electrical and Electronics Engineers Inc., 2016. S. 191-194 7785498 (Annual Report - Conference on Electrical Insulation and Dielectric Phenomena, CEIDP; Band 2016-December).
Publikation: Beitrag in Buch/Bericht/Sammelwerk/Konferenzband › Aufsatz in Konferenzband › Forschung › Peer-Review
}
TY - GEN
T1 - Determination of transfer function of power transformer winding sections for partial discharge localization using design information
AU - Rahimbakhsh, Mahdi
AU - Werle, Peter
AU - Gockenbach, Ernst
N1 - Publisher Copyright: © 2016 IEEE. Copyright: Copyright 2017 Elsevier B.V., All rights reserved.
PY - 2016/12/15
Y1 - 2016/12/15
N2 - The paper focuses on simulating the transfer function of power transformer winding sections based on design information. The calculation method has been investigated and discussed. The simulation of windings through multi conductor transmission line method has been performed for an actual distribution transformer in the laboratory using the design information. With this information the transfer function of the transformer winding sections has been calculated. Additionally some measurements on the distribution transformer have been done in three test platforms with different measurement devices in order to compare the methods for evaluating the transfer function of this transformer. The simulated transfer function has been adapted by comparison between the simulation and measurement results. As a result of the comparison, a deviation factor could be defined and the most sensitive parameters of the simulation methods could be identified. The difference between simulation and measurement leads to knowledge about the required measurements on a transformer as basis for the simulation of the transfer function of the transformer winding sections.
AB - The paper focuses on simulating the transfer function of power transformer winding sections based on design information. The calculation method has been investigated and discussed. The simulation of windings through multi conductor transmission line method has been performed for an actual distribution transformer in the laboratory using the design information. With this information the transfer function of the transformer winding sections has been calculated. Additionally some measurements on the distribution transformer have been done in three test platforms with different measurement devices in order to compare the methods for evaluating the transfer function of this transformer. The simulated transfer function has been adapted by comparison between the simulation and measurement results. As a result of the comparison, a deviation factor could be defined and the most sensitive parameters of the simulation methods could be identified. The difference between simulation and measurement leads to knowledge about the required measurements on a transformer as basis for the simulation of the transfer function of the transformer winding sections.
UR - http://www.scopus.com/inward/record.url?scp=85009829433&partnerID=8YFLogxK
U2 - 10.1109/CEIDP.2016.7785498
DO - 10.1109/CEIDP.2016.7785498
M3 - Conference contribution
AN - SCOPUS:85009829433
T3 - Annual Report - Conference on Electrical Insulation and Dielectric Phenomena, CEIDP
SP - 191
EP - 194
BT - 2016 IEEE Conference on Electrical Insulation and Dielectric Phenomena, CEIDP 2016
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2016 IEEE Conference on Electrical Insulation and Dielectric Phenomena, CEIDP 2016
Y2 - 16 October 2016 through 19 October 2016
ER -