Abstract
This paper deals with some ageing investigations on two insulating fluids which appear to be particularly suitable for the retrofilling of a perchlorethylene based fluid (Transclene) filled transformers. After a description of the ageing procedure some details of the changes in both the dielectrical and electrical behaviour are described. A comparison of the measured values with the predetermination of the relevant standards and the consequences for the use of the insulation liquid mixture are presented.
ASJC Scopus Sachgebiete
- Ingenieurwesen (insg.)
- Elektrotechnik und Elektronik
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
IEE Conference Publication. 467. Aufl. 1999. S. 3.360.P4-3.363.P4 (IEE Conference Publication; Band 3, Nr. 467).
Publikation: Beitrag in Buch/Bericht/Sammelwerk/Konferenzband › Aufsatz in Konferenzband › Forschung › Peer-Review
}
TY - GEN
T1 - Determination of the electrical properties of mixed transformer fluids under thermal ageing
AU - Fofana, I.
AU - Wasserberg, V.
AU - Borsi, H.
AU - Gockenbach, E.
N1 - Copyright: Copyright 2007 Elsevier B.V., All rights reserved.
PY - 1999
Y1 - 1999
N2 - This paper deals with some ageing investigations on two insulating fluids which appear to be particularly suitable for the retrofilling of a perchlorethylene based fluid (Transclene) filled transformers. After a description of the ageing procedure some details of the changes in both the dielectrical and electrical behaviour are described. A comparison of the measured values with the predetermination of the relevant standards and the consequences for the use of the insulation liquid mixture are presented.
AB - This paper deals with some ageing investigations on two insulating fluids which appear to be particularly suitable for the retrofilling of a perchlorethylene based fluid (Transclene) filled transformers. After a description of the ageing procedure some details of the changes in both the dielectrical and electrical behaviour are described. A comparison of the measured values with the predetermination of the relevant standards and the consequences for the use of the insulation liquid mixture are presented.
UR - http://www.scopus.com/inward/record.url?scp=0033348535&partnerID=8YFLogxK
M3 - Conference contribution
AN - SCOPUS:0033348535
SN - 0852967195
T3 - IEE Conference Publication
SP - 3.360.P4-3.363.P4
BT - IEE Conference Publication
T2 - 1999 11th International Symposium on 'High Voltage Engineering' (ish99)
Y2 - 23 August 1999 through 27 August 1999
ER -