Design of a novel MEMS based laser scanning laryngoscope to combine high precision laser cuts with simultaneous MHz OCT and stereo camera feedback

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Autoren

  • James W. Napier
  • Sontje Ihler
  • Max Heinrich Laves
  • Miroslav Zabic
  • Alexander Heisterkamp
  • Walter Neu

Externe Organisationen

  • Hochschule Emden/Leer
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Titel des SammelwerksImaging, Therapeutics, and Advanced Technology in Head and Neck Surgery and Otolaryngology 2020
Herausgeber (Verlag)SPIE
ISBN (elektronisch)9781510631892
PublikationsstatusVeröffentlicht - 19 Feb. 2020
VeranstaltungImaging, Therapeutics, and Advanced Technology in Head and Neck Surgery and Otolaryngology 2020 - San Francisco, USA / Vereinigte Staaten
Dauer: 1 Feb. 2020 → …

Publikationsreihe

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Band11213
ISSN (Print)1605-7422

Abstract

Current laser surgery on vocal chords requires the patient to be under general anaesthesia due to relatively low cutting speed and precision. Even minor surgeries can change vocal properties, requiring lengthy post-operative therapy. To solve this problem and reduce recovery time we propose a laryngoscope capable of performing the surgery while the patient is awake. To realize this, it is necessary for each cut to be made on the shortest time scale with the highest precision possible. It is also important to have high speed feedback to initiate or terminate the cutting process as well as to maintain the proper cutting position. In this laryngoscope we employ a coaxial MHz OCT and laser cutting system with a MEMS galvo scanner combined with a high speed stereo camera set. The MHz OCT is responsible for axial feedback and measuring the depth of cut while the stereo camera set is used to adjust the MEMS scanner for lateral offsets. We have determined the optimal optical layout for the laryngoscope using Zemax and have developed 3D CAD models of the prototype demonstrator prior to fabrication and assembly. This new laryngoscope could make laser cuts up to 50% smaller in width than traditional multimode fiber based cuts, in addition to reducing overall surgery time and increasing the precision of each cut.

ASJC Scopus Sachgebiete

Zitieren

Design of a novel MEMS based laser scanning laryngoscope to combine high precision laser cuts with simultaneous MHz OCT and stereo camera feedback. / Napier, James W.; Ihler, Sontje; Laves, Max Heinrich et al.
Imaging, Therapeutics, and Advanced Technology in Head and Neck Surgery and Otolaryngology 2020. SPIE, 2020. 112130J (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; Band 11213).

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Napier, JW, Ihler, S, Laves, MH, Zabic, M, Heisterkamp, A & Neu, W 2020, Design of a novel MEMS based laser scanning laryngoscope to combine high precision laser cuts with simultaneous MHz OCT and stereo camera feedback. in Imaging, Therapeutics, and Advanced Technology in Head and Neck Surgery and Otolaryngology 2020., 112130J, Progress in Biomedical Optics and Imaging - Proceedings of SPIE, Bd. 11213, SPIE, Imaging, Therapeutics, and Advanced Technology in Head and Neck Surgery and Otolaryngology 2020, San Francisco, USA / Vereinigte Staaten, 1 Feb. 2020. https://doi.org/10.1117/12.2550806
Napier, J. W., Ihler, S., Laves, M. H., Zabic, M., Heisterkamp, A., & Neu, W. (2020). Design of a novel MEMS based laser scanning laryngoscope to combine high precision laser cuts with simultaneous MHz OCT and stereo camera feedback. In Imaging, Therapeutics, and Advanced Technology in Head and Neck Surgery and Otolaryngology 2020 Artikel 112130J (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; Band 11213). SPIE. https://doi.org/10.1117/12.2550806
Napier JW, Ihler S, Laves MH, Zabic M, Heisterkamp A, Neu W. Design of a novel MEMS based laser scanning laryngoscope to combine high precision laser cuts with simultaneous MHz OCT and stereo camera feedback. in Imaging, Therapeutics, and Advanced Technology in Head and Neck Surgery and Otolaryngology 2020. SPIE. 2020. 112130J. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE). doi: 10.1117/12.2550806
Napier, James W. ; Ihler, Sontje ; Laves, Max Heinrich et al. / Design of a novel MEMS based laser scanning laryngoscope to combine high precision laser cuts with simultaneous MHz OCT and stereo camera feedback. Imaging, Therapeutics, and Advanced Technology in Head and Neck Surgery and Otolaryngology 2020. SPIE, 2020. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE).
Download
@inproceedings{0442caa2be4c4695917b42bbe117d08e,
title = "Design of a novel MEMS based laser scanning laryngoscope to combine high precision laser cuts with simultaneous MHz OCT and stereo camera feedback",
abstract = "Current laser surgery on vocal chords requires the patient to be under general anaesthesia due to relatively low cutting speed and precision. Even minor surgeries can change vocal properties, requiring lengthy post-operative therapy. To solve this problem and reduce recovery time we propose a laryngoscope capable of performing the surgery while the patient is awake. To realize this, it is necessary for each cut to be made on the shortest time scale with the highest precision possible. It is also important to have high speed feedback to initiate or terminate the cutting process as well as to maintain the proper cutting position. In this laryngoscope we employ a coaxial MHz OCT and laser cutting system with a MEMS galvo scanner combined with a high speed stereo camera set. The MHz OCT is responsible for axial feedback and measuring the depth of cut while the stereo camera set is used to adjust the MEMS scanner for lateral offsets. We have determined the optimal optical layout for the laryngoscope using Zemax and have developed 3D CAD models of the prototype demonstrator prior to fabrication and assembly. This new laryngoscope could make laser cuts up to 50% smaller in width than traditional multimode fiber based cuts, in addition to reducing overall surgery time and increasing the precision of each cut.",
keywords = "Laryngoscope, Laser surgery, MEMS scanner, MHz OCT, Stereo camera, Vocal chords",
author = "Napier, {James W.} and Sontje Ihler and Laves, {Max Heinrich} and Miroslav Zabic and Alexander Heisterkamp and Walter Neu",
note = "Funding Information: We gratefully acknowledge the Europ{\"a}ischer Fond f{\"u}r Regionale Entwicklung (EFRE) and the state Niedersachsen for funding the project “OPhonLas -OCT-geregelte Laserablation bei Stimmlippen-Phonation{"}.; Imaging, Therapeutics, and Advanced Technology in Head and Neck Surgery and Otolaryngology 2020 ; Conference date: 01-02-2020",
year = "2020",
month = feb,
day = "19",
doi = "10.1117/12.2550806",
language = "English",
series = "Progress in Biomedical Optics and Imaging - Proceedings of SPIE",
publisher = "SPIE",
booktitle = "Imaging, Therapeutics, and Advanced Technology in Head and Neck Surgery and Otolaryngology 2020",
address = "United States",

}

Download

TY - GEN

T1 - Design of a novel MEMS based laser scanning laryngoscope to combine high precision laser cuts with simultaneous MHz OCT and stereo camera feedback

AU - Napier, James W.

AU - Ihler, Sontje

AU - Laves, Max Heinrich

AU - Zabic, Miroslav

AU - Heisterkamp, Alexander

AU - Neu, Walter

N1 - Funding Information: We gratefully acknowledge the Europäischer Fond für Regionale Entwicklung (EFRE) and the state Niedersachsen for funding the project “OPhonLas -OCT-geregelte Laserablation bei Stimmlippen-Phonation".

PY - 2020/2/19

Y1 - 2020/2/19

N2 - Current laser surgery on vocal chords requires the patient to be under general anaesthesia due to relatively low cutting speed and precision. Even minor surgeries can change vocal properties, requiring lengthy post-operative therapy. To solve this problem and reduce recovery time we propose a laryngoscope capable of performing the surgery while the patient is awake. To realize this, it is necessary for each cut to be made on the shortest time scale with the highest precision possible. It is also important to have high speed feedback to initiate or terminate the cutting process as well as to maintain the proper cutting position. In this laryngoscope we employ a coaxial MHz OCT and laser cutting system with a MEMS galvo scanner combined with a high speed stereo camera set. The MHz OCT is responsible for axial feedback and measuring the depth of cut while the stereo camera set is used to adjust the MEMS scanner for lateral offsets. We have determined the optimal optical layout for the laryngoscope using Zemax and have developed 3D CAD models of the prototype demonstrator prior to fabrication and assembly. This new laryngoscope could make laser cuts up to 50% smaller in width than traditional multimode fiber based cuts, in addition to reducing overall surgery time and increasing the precision of each cut.

AB - Current laser surgery on vocal chords requires the patient to be under general anaesthesia due to relatively low cutting speed and precision. Even minor surgeries can change vocal properties, requiring lengthy post-operative therapy. To solve this problem and reduce recovery time we propose a laryngoscope capable of performing the surgery while the patient is awake. To realize this, it is necessary for each cut to be made on the shortest time scale with the highest precision possible. It is also important to have high speed feedback to initiate or terminate the cutting process as well as to maintain the proper cutting position. In this laryngoscope we employ a coaxial MHz OCT and laser cutting system with a MEMS galvo scanner combined with a high speed stereo camera set. The MHz OCT is responsible for axial feedback and measuring the depth of cut while the stereo camera set is used to adjust the MEMS scanner for lateral offsets. We have determined the optimal optical layout for the laryngoscope using Zemax and have developed 3D CAD models of the prototype demonstrator prior to fabrication and assembly. This new laryngoscope could make laser cuts up to 50% smaller in width than traditional multimode fiber based cuts, in addition to reducing overall surgery time and increasing the precision of each cut.

KW - Laryngoscope

KW - Laser surgery

KW - MEMS scanner

KW - MHz OCT

KW - Stereo camera

KW - Vocal chords

UR - http://www.scopus.com/inward/record.url?scp=85081534875&partnerID=8YFLogxK

U2 - 10.1117/12.2550806

DO - 10.1117/12.2550806

M3 - Conference contribution

AN - SCOPUS:85081534875

T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE

BT - Imaging, Therapeutics, and Advanced Technology in Head and Neck Surgery and Otolaryngology 2020

PB - SPIE

T2 - Imaging, Therapeutics, and Advanced Technology in Head and Neck Surgery and Otolaryngology 2020

Y2 - 1 February 2020

ER -

Von denselben Autoren