Der lichtstreudetektor (ELSD) in der lebensmittelanalytik

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

  • J. Onken
  • R. G. Berger

Organisationseinheiten

Forschungs-netzwerk anzeigen

Details

OriginalspracheDeutsch
Seiten (von - bis)287-291
Seitenumfang5
FachzeitschriftDeutsche Lebensmittel-Rundschau
Jahrgang94
Ausgabenummer9
PublikationsstatusVeröffentlicht - Sept. 1998

Abstract

The evaporative light scattering detector (ELSD) is a universal HPLC-detector with many applications for non-volatile constituents of foods. In contrast to the refractive index detector, the ELSD is compatible with gradient elution and, therefore, suitable for complex samples. The function of the detector and the effects of parameters, such as properties of the eluent, flow rates of carrier gas and eluent, evaporation temperature, and structure of the analyte on detector sensitivity are explained. For quantitative results, an optimization of the detection parameters and a precise calibration are necessary. Calibration curves are sigmoidal, and the linear range mostly extends to one or two orders of magnitude Relative standard deviations of around 1% can be obtained. Detection limits in the middle or upper ng-range are to be expected. Applications for the analysis of lipids, carbohydrates and other important classes of natural compounds are compiled.

ASJC Scopus Sachgebiete

Zitieren

Der lichtstreudetektor (ELSD) in der lebensmittelanalytik. / Onken, J.; Berger, R. G.
in: Deutsche Lebensmittel-Rundschau, Jahrgang 94, Nr. 9, 09.1998, S. 287-291.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Onken, J & Berger, RG 1998, 'Der lichtstreudetektor (ELSD) in der lebensmittelanalytik', Deutsche Lebensmittel-Rundschau, Jg. 94, Nr. 9, S. 287-291.
Onken, J. ; Berger, R. G. / Der lichtstreudetektor (ELSD) in der lebensmittelanalytik. in: Deutsche Lebensmittel-Rundschau. 1998 ; Jahrgang 94, Nr. 9. S. 287-291.
Download
@article{3287fb4908e940acb3e025b97ca143b1,
title = "Der lichtstreudetektor (ELSD) in der lebensmittelanalytik",
abstract = "The evaporative light scattering detector (ELSD) is a universal HPLC-detector with many applications for non-volatile constituents of foods. In contrast to the refractive index detector, the ELSD is compatible with gradient elution and, therefore, suitable for complex samples. The function of the detector and the effects of parameters, such as properties of the eluent, flow rates of carrier gas and eluent, evaporation temperature, and structure of the analyte on detector sensitivity are explained. For quantitative results, an optimization of the detection parameters and a precise calibration are necessary. Calibration curves are sigmoidal, and the linear range mostly extends to one or two orders of magnitude Relative standard deviations of around 1% can be obtained. Detection limits in the middle or upper ng-range are to be expected. Applications for the analysis of lipids, carbohydrates and other important classes of natural compounds are compiled.",
author = "J. Onken and Berger, {R. G.}",
year = "1998",
month = sep,
language = "Deutsch",
volume = "94",
pages = "287--291",
journal = "Deutsche Lebensmittel-Rundschau",
issn = "0012-0413",
publisher = "Wissenschaftliche Verlagsgesellschaft Stuttgart",
number = "9",

}

Download

TY - JOUR

T1 - Der lichtstreudetektor (ELSD) in der lebensmittelanalytik

AU - Onken, J.

AU - Berger, R. G.

PY - 1998/9

Y1 - 1998/9

N2 - The evaporative light scattering detector (ELSD) is a universal HPLC-detector with many applications for non-volatile constituents of foods. In contrast to the refractive index detector, the ELSD is compatible with gradient elution and, therefore, suitable for complex samples. The function of the detector and the effects of parameters, such as properties of the eluent, flow rates of carrier gas and eluent, evaporation temperature, and structure of the analyte on detector sensitivity are explained. For quantitative results, an optimization of the detection parameters and a precise calibration are necessary. Calibration curves are sigmoidal, and the linear range mostly extends to one or two orders of magnitude Relative standard deviations of around 1% can be obtained. Detection limits in the middle or upper ng-range are to be expected. Applications for the analysis of lipids, carbohydrates and other important classes of natural compounds are compiled.

AB - The evaporative light scattering detector (ELSD) is a universal HPLC-detector with many applications for non-volatile constituents of foods. In contrast to the refractive index detector, the ELSD is compatible with gradient elution and, therefore, suitable for complex samples. The function of the detector and the effects of parameters, such as properties of the eluent, flow rates of carrier gas and eluent, evaporation temperature, and structure of the analyte on detector sensitivity are explained. For quantitative results, an optimization of the detection parameters and a precise calibration are necessary. Calibration curves are sigmoidal, and the linear range mostly extends to one or two orders of magnitude Relative standard deviations of around 1% can be obtained. Detection limits in the middle or upper ng-range are to be expected. Applications for the analysis of lipids, carbohydrates and other important classes of natural compounds are compiled.

UR - http://www.scopus.com/inward/record.url?scp=0039447822&partnerID=8YFLogxK

M3 - Artikel

AN - SCOPUS:0039447822

VL - 94

SP - 287

EP - 291

JO - Deutsche Lebensmittel-Rundschau

JF - Deutsche Lebensmittel-Rundschau

SN - 0012-0413

IS - 9

ER -