Loading [MathJax]/extensions/tex2jax.js

Comparison of Different Methods for the Analysis of Time-Resolved Flow Field Measurements in an Axial Turbine

Publikation: KonferenzbeitragPaperForschungPeer-Review

Autorschaft

  • T. Kluge
  • M. Henke
  • J. R. Seume

Details

OriginalspracheEnglisch
PublikationsstatusVeröffentlicht - 2015
Veranstaltung11th European Conference on Turbomachinery Fluid Dynamics and Thermodynamics, ETC 2015 - Madrid, Spanien
Dauer: 23 März 201527 März 2015

Konferenz

Konferenz11th European Conference on Turbomachinery Fluid Dynamics and Thermodynamics, ETC 2015
Land/GebietSpanien
OrtMadrid
Zeitraum23 März 201527 März 2015

Abstract

To resolve secondary flows and wakes in turbomachinery measurements, reduction methods capable of isolating the deterministic and stochastic components of a given signal must be implemented. In the present study, two approaches are applied: a trigger-based phase-locked ensemble averaging technique and a newly proposed method based on the deconvolution of the signal in the frequency domain. While the former is used in numerous publications on the measurement of secondary flows, the latter has-to these authors' knowledge-not yet been used in this context. Both data reduction techniques are outlined theoretically and applied to unsteady pressure measurements in a multi-stage axial turbine. Results obtained from the proposed deconvolution method are in good qualitative agreement with ensemble-averaged data. In some cases, a quantitative discrepancy is shown, most likely caused by numerical errors. Nevertheless, within certain boundaries the method is capable of isolating the deterministic signal including non-rotationally harmonic components without the need for a trigger signal.

ASJC Scopus Sachgebiete

Zitieren

Comparison of Different Methods for the Analysis of Time-Resolved Flow Field Measurements in an Axial Turbine. / Kluge, T.; Henke, M.; Seume, J. R.
2015. Beitrag in 11th European Conference on Turbomachinery Fluid Dynamics and Thermodynamics, ETC 2015, Madrid, Spanien.

Publikation: KonferenzbeitragPaperForschungPeer-Review

Kluge, T, Henke, M & Seume, JR 2015, 'Comparison of Different Methods for the Analysis of Time-Resolved Flow Field Measurements in an Axial Turbine', Beitrag in 11th European Conference on Turbomachinery Fluid Dynamics and Thermodynamics, ETC 2015, Madrid, Spanien, 23 März 2015 - 27 März 2015.
Kluge, T., Henke, M., & Seume, J. R. (2015). Comparison of Different Methods for the Analysis of Time-Resolved Flow Field Measurements in an Axial Turbine. Beitrag in 11th European Conference on Turbomachinery Fluid Dynamics and Thermodynamics, ETC 2015, Madrid, Spanien.
Kluge T, Henke M, Seume JR. Comparison of Different Methods for the Analysis of Time-Resolved Flow Field Measurements in an Axial Turbine. 2015. Beitrag in 11th European Conference on Turbomachinery Fluid Dynamics and Thermodynamics, ETC 2015, Madrid, Spanien.
Kluge, T. ; Henke, M. ; Seume, J. R. / Comparison of Different Methods for the Analysis of Time-Resolved Flow Field Measurements in an Axial Turbine. Beitrag in 11th European Conference on Turbomachinery Fluid Dynamics and Thermodynamics, ETC 2015, Madrid, Spanien.
Download
@conference{89524695263040a287fbedae4796edbe,
title = "Comparison of Different Methods for the Analysis of Time-Resolved Flow Field Measurements in an Axial Turbine",
abstract = "To resolve secondary flows and wakes in turbomachinery measurements, reduction methods capable of isolating the deterministic and stochastic components of a given signal must be implemented. In the present study, two approaches are applied: a trigger-based phase-locked ensemble averaging technique and a newly proposed method based on the deconvolution of the signal in the frequency domain. While the former is used in numerous publications on the measurement of secondary flows, the latter has-to these authors' knowledge-not yet been used in this context. Both data reduction techniques are outlined theoretically and applied to unsteady pressure measurements in a multi-stage axial turbine. Results obtained from the proposed deconvolution method are in good qualitative agreement with ensemble-averaged data. In some cases, a quantitative discrepancy is shown, most likely caused by numerical errors. Nevertheless, within certain boundaries the method is capable of isolating the deterministic signal including non-rotationally harmonic components without the need for a trigger signal.",
author = "T. Kluge and M. Henke and Seume, {J. R.}",
year = "2015",
language = "English",
note = "11th European Conference on Turbomachinery Fluid Dynamics and Thermodynamics, ETC 2015 ; Conference date: 23-03-2015 Through 27-03-2015",

}

Download

TY - CONF

T1 - Comparison of Different Methods for the Analysis of Time-Resolved Flow Field Measurements in an Axial Turbine

AU - Kluge, T.

AU - Henke, M.

AU - Seume, J. R.

PY - 2015

Y1 - 2015

N2 - To resolve secondary flows and wakes in turbomachinery measurements, reduction methods capable of isolating the deterministic and stochastic components of a given signal must be implemented. In the present study, two approaches are applied: a trigger-based phase-locked ensemble averaging technique and a newly proposed method based on the deconvolution of the signal in the frequency domain. While the former is used in numerous publications on the measurement of secondary flows, the latter has-to these authors' knowledge-not yet been used in this context. Both data reduction techniques are outlined theoretically and applied to unsteady pressure measurements in a multi-stage axial turbine. Results obtained from the proposed deconvolution method are in good qualitative agreement with ensemble-averaged data. In some cases, a quantitative discrepancy is shown, most likely caused by numerical errors. Nevertheless, within certain boundaries the method is capable of isolating the deterministic signal including non-rotationally harmonic components without the need for a trigger signal.

AB - To resolve secondary flows and wakes in turbomachinery measurements, reduction methods capable of isolating the deterministic and stochastic components of a given signal must be implemented. In the present study, two approaches are applied: a trigger-based phase-locked ensemble averaging technique and a newly proposed method based on the deconvolution of the signal in the frequency domain. While the former is used in numerous publications on the measurement of secondary flows, the latter has-to these authors' knowledge-not yet been used in this context. Both data reduction techniques are outlined theoretically and applied to unsteady pressure measurements in a multi-stage axial turbine. Results obtained from the proposed deconvolution method are in good qualitative agreement with ensemble-averaged data. In some cases, a quantitative discrepancy is shown, most likely caused by numerical errors. Nevertheless, within certain boundaries the method is capable of isolating the deterministic signal including non-rotationally harmonic components without the need for a trigger signal.

UR - http://www.scopus.com/inward/record.url?scp=85064774092&partnerID=8YFLogxK

M3 - Paper

T2 - 11th European Conference on Turbomachinery Fluid Dynamics and Thermodynamics, ETC 2015

Y2 - 23 March 2015 through 27 March 2015

ER -