Challenging the Standard Model by high precision comparisons of the fundamental properties of antiprotons and protons

Publikation: Qualifikations-/StudienabschlussarbeitDissertation

Autoren

  • Matthias Joachim Borchert

Organisationseinheiten

Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
QualifikationDoctor rerum naturalium
Gradverleihende Hochschule
Betreut von
Datum der Verleihung des Grades28 Jan. 2021
ErscheinungsortHannover
PublikationsstatusVeröffentlicht - 2021

Abstract

This thesis describes high precision measurements on the fundamental properties of the antiproton, namely the charge-to-mass ratio and the magnetic moment. This work is embedded in the experimental work of the BASE collaboration (Baryon Antibaryon Symmetry Experiment). BASE operates a sophisticated cryogenic Multi-Penning trap system in the Antiproton Decelerator facility at CERN. One main result of this thesis are significant technical improvements of the apparatus, which reduced the limitation of shot-to-shot cyclotron frequency scatter by a factor of more than five compared to earlier work. With this improved apparatus, a measurement campaign on the antiproton-to-proton charge-to-mass ratio with a statistical uncertainty of 20×10−12 and an overall uncertainty of about 35 × 10−12 was conducted. This campaign was part of a series of charge-to-mass ratio measurements on the antiproton with the overall goal to significantly improve the previous best measurement conducted by BASE in 2014, which yielded a fractional uncertainty of 69×10−12. In this thesis, also the first dedicated heating rate measurement in a cryogenic Penning trap experiment is described. Here, the lowest heating rates ever reported for an ion trap were observed. As part of this thesis, phase sensitive methods for measuring the cyclotron frequency of a single trapped ion were implemented in the BASE experiment. These methods allowed to measure the cyclotron frequency with a shot-to-shot scatter improved by a factor of five compared to methods used in previous experiments. The significant improvements in cyclotron frequency scatter open up the possibility to measure the antiproton magnetic moment and the antiproton charge-to-mass ratio with much increased precision, and thereby enable more stringent tests of the fundamental CPT symmetry by direct comparisons of matter/antimatter conjugates.

Zitieren

Challenging the Standard Model by high precision comparisons of the fundamental properties of antiprotons and protons. / Borchert, Matthias Joachim.
Hannover, 2021. 246 S.

Publikation: Qualifikations-/StudienabschlussarbeitDissertation

Borchert, MJ 2021, 'Challenging the Standard Model by high precision comparisons of the fundamental properties of antiprotons and protons', Doctor rerum naturalium, Gottfried Wilhelm Leibniz Universität Hannover, Hannover. https://doi.org/10.15488/11564
Download
@phdthesis{74b99d6b043748f8a536a17fca12b91d,
title = "Challenging the Standard Model by high precision comparisons of the fundamental properties of antiprotons and protons",
abstract = "This thesis describes high precision measurements on the fundamental properties of the antiproton, namely the charge-to-mass ratio and the magnetic moment. This work is embedded in the experimental work of the BASE collaboration (Baryon Antibaryon Symmetry Experiment). BASE operates a sophisticated cryogenic Multi-Penning trap system in the Antiproton Decelerator facility at CERN. One main result of this thesis are significant technical improvements of the apparatus, which reduced the limitation of shot-to-shot cyclotron frequency scatter by a factor of more than five compared to earlier work. With this improved apparatus, a measurement campaign on the antiproton-to-proton charge-to-mass ratio with a statistical uncertainty of 20×10−12 and an overall uncertainty of about 35 × 10−12 was conducted. This campaign was part of a series of charge-to-mass ratio measurements on the antiproton with the overall goal to significantly improve the previous best measurement conducted by BASE in 2014, which yielded a fractional uncertainty of 69×10−12. In this thesis, also the first dedicated heating rate measurement in a cryogenic Penning trap experiment is described. Here, the lowest heating rates ever reported for an ion trap were observed. As part of this thesis, phase sensitive methods for measuring the cyclotron frequency of a single trapped ion were implemented in the BASE experiment. These methods allowed to measure the cyclotron frequency with a shot-to-shot scatter improved by a factor of five compared to methods used in previous experiments. The significant improvements in cyclotron frequency scatter open up the possibility to measure the antiproton magnetic moment and the antiproton charge-to-mass ratio with much increased precision, and thereby enable more stringent tests of the fundamental CPT symmetry by direct comparisons of matter/antimatter conjugates.",
author = "Borchert, {Matthias Joachim}",
note = "Doctoral thesis",
year = "2021",
doi = "10.15488/11564",
language = "English",
school = "Leibniz University Hannover",

}

Download

TY - BOOK

T1 - Challenging the Standard Model by high precision comparisons of the fundamental properties of antiprotons and protons

AU - Borchert, Matthias Joachim

N1 - Doctoral thesis

PY - 2021

Y1 - 2021

N2 - This thesis describes high precision measurements on the fundamental properties of the antiproton, namely the charge-to-mass ratio and the magnetic moment. This work is embedded in the experimental work of the BASE collaboration (Baryon Antibaryon Symmetry Experiment). BASE operates a sophisticated cryogenic Multi-Penning trap system in the Antiproton Decelerator facility at CERN. One main result of this thesis are significant technical improvements of the apparatus, which reduced the limitation of shot-to-shot cyclotron frequency scatter by a factor of more than five compared to earlier work. With this improved apparatus, a measurement campaign on the antiproton-to-proton charge-to-mass ratio with a statistical uncertainty of 20×10−12 and an overall uncertainty of about 35 × 10−12 was conducted. This campaign was part of a series of charge-to-mass ratio measurements on the antiproton with the overall goal to significantly improve the previous best measurement conducted by BASE in 2014, which yielded a fractional uncertainty of 69×10−12. In this thesis, also the first dedicated heating rate measurement in a cryogenic Penning trap experiment is described. Here, the lowest heating rates ever reported for an ion trap were observed. As part of this thesis, phase sensitive methods for measuring the cyclotron frequency of a single trapped ion were implemented in the BASE experiment. These methods allowed to measure the cyclotron frequency with a shot-to-shot scatter improved by a factor of five compared to methods used in previous experiments. The significant improvements in cyclotron frequency scatter open up the possibility to measure the antiproton magnetic moment and the antiproton charge-to-mass ratio with much increased precision, and thereby enable more stringent tests of the fundamental CPT symmetry by direct comparisons of matter/antimatter conjugates.

AB - This thesis describes high precision measurements on the fundamental properties of the antiproton, namely the charge-to-mass ratio and the magnetic moment. This work is embedded in the experimental work of the BASE collaboration (Baryon Antibaryon Symmetry Experiment). BASE operates a sophisticated cryogenic Multi-Penning trap system in the Antiproton Decelerator facility at CERN. One main result of this thesis are significant technical improvements of the apparatus, which reduced the limitation of shot-to-shot cyclotron frequency scatter by a factor of more than five compared to earlier work. With this improved apparatus, a measurement campaign on the antiproton-to-proton charge-to-mass ratio with a statistical uncertainty of 20×10−12 and an overall uncertainty of about 35 × 10−12 was conducted. This campaign was part of a series of charge-to-mass ratio measurements on the antiproton with the overall goal to significantly improve the previous best measurement conducted by BASE in 2014, which yielded a fractional uncertainty of 69×10−12. In this thesis, also the first dedicated heating rate measurement in a cryogenic Penning trap experiment is described. Here, the lowest heating rates ever reported for an ion trap were observed. As part of this thesis, phase sensitive methods for measuring the cyclotron frequency of a single trapped ion were implemented in the BASE experiment. These methods allowed to measure the cyclotron frequency with a shot-to-shot scatter improved by a factor of five compared to methods used in previous experiments. The significant improvements in cyclotron frequency scatter open up the possibility to measure the antiproton magnetic moment and the antiproton charge-to-mass ratio with much increased precision, and thereby enable more stringent tests of the fundamental CPT symmetry by direct comparisons of matter/antimatter conjugates.

U2 - 10.15488/11564

DO - 10.15488/11564

M3 - Doctoral thesis

CY - Hannover

ER -

Von denselben Autoren