Details
Originalsprache | Englisch |
---|---|
Seiten (von - bis) | 85-90 |
Seitenumfang | 6 |
Fachzeitschrift | Advances in Radio Science |
Jahrgang | 14 |
Publikationsstatus | Veröffentlicht - 28 Sept. 2016 |
Extern publiziert | Ja |
Abstract
Switched-mode power supplies (SMPS) convert an input DC-voltage into a higher or lower output voltage. In automotive, analog control is mostly used in order to keep the required output voltages constant and resistant to disturbances. The design of robust analog control for SMPS faces parameter variations of integrated and external passive components. Using digital control, parameter variations can be eliminated and the required area for the integrated circuit can be reduced at the same time. Digital control design bears challenges like the prevention of limit cycle oscillations and controller-wind-up. This paper reviews how to prevent these effects. Digital control loops introduce new sources for dead times in the control loop, for example the latency of the analog-to-digital-converter (ADC). Dead times have negative influence on the stability of the control loop, because they lead to phase delays. Consequently, low latency is one of the key requirements for analog-to-digital-converters in digitally controlled SMPS. Exploiting the example of a 500 kHz-buck converter with a crossover frequency of 70 kHz, this paper shows that the 5 μs-latency of a δ ∑-analog-to-digital-converter leads to a reduction in phase margin of 126°. The latency is less critical for boost converters because of their inherent lower crossover frequencies. Finally, the paper shows a comparison between analog and digital control of SMPS with regard to chip area and test costs.
ASJC Scopus Sachgebiete
- Ingenieurwesen (insg.)
- Elektrotechnik und Elektronik
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
in: Advances in Radio Science, Jahrgang 14, 28.09.2016, S. 85-90.
Publikation: Beitrag in Fachzeitschrift › Artikel › Forschung › Peer-Review
}
TY - JOUR
T1 - Challenges and implementation aspects of switched-mode power supplies with digital control for automotive applications
AU - Quenzer-Hohmuth, Samuel
AU - Rosahl, Thoralf
AU - Ritzmann, Steffen
AU - Wicht, Bernhard
N1 - Publisher Copyright: © 2016 Author(s).
PY - 2016/9/28
Y1 - 2016/9/28
N2 - Switched-mode power supplies (SMPS) convert an input DC-voltage into a higher or lower output voltage. In automotive, analog control is mostly used in order to keep the required output voltages constant and resistant to disturbances. The design of robust analog control for SMPS faces parameter variations of integrated and external passive components. Using digital control, parameter variations can be eliminated and the required area for the integrated circuit can be reduced at the same time. Digital control design bears challenges like the prevention of limit cycle oscillations and controller-wind-up. This paper reviews how to prevent these effects. Digital control loops introduce new sources for dead times in the control loop, for example the latency of the analog-to-digital-converter (ADC). Dead times have negative influence on the stability of the control loop, because they lead to phase delays. Consequently, low latency is one of the key requirements for analog-to-digital-converters in digitally controlled SMPS. Exploiting the example of a 500 kHz-buck converter with a crossover frequency of 70 kHz, this paper shows that the 5 μs-latency of a δ ∑-analog-to-digital-converter leads to a reduction in phase margin of 126°. The latency is less critical for boost converters because of their inherent lower crossover frequencies. Finally, the paper shows a comparison between analog and digital control of SMPS with regard to chip area and test costs.
AB - Switched-mode power supplies (SMPS) convert an input DC-voltage into a higher or lower output voltage. In automotive, analog control is mostly used in order to keep the required output voltages constant and resistant to disturbances. The design of robust analog control for SMPS faces parameter variations of integrated and external passive components. Using digital control, parameter variations can be eliminated and the required area for the integrated circuit can be reduced at the same time. Digital control design bears challenges like the prevention of limit cycle oscillations and controller-wind-up. This paper reviews how to prevent these effects. Digital control loops introduce new sources for dead times in the control loop, for example the latency of the analog-to-digital-converter (ADC). Dead times have negative influence on the stability of the control loop, because they lead to phase delays. Consequently, low latency is one of the key requirements for analog-to-digital-converters in digitally controlled SMPS. Exploiting the example of a 500 kHz-buck converter with a crossover frequency of 70 kHz, this paper shows that the 5 μs-latency of a δ ∑-analog-to-digital-converter leads to a reduction in phase margin of 126°. The latency is less critical for boost converters because of their inherent lower crossover frequencies. Finally, the paper shows a comparison between analog and digital control of SMPS with regard to chip area and test costs.
UR - http://www.scopus.com/inward/record.url?scp=84990026645&partnerID=8YFLogxK
U2 - 10.5194/ars-14-85-2016
DO - 10.5194/ars-14-85-2016
M3 - Article
AN - SCOPUS:84990026645
VL - 14
SP - 85
EP - 90
JO - Advances in Radio Science
JF - Advances in Radio Science
SN - 1684-9965
ER -