Details
Originalsprache | Englisch |
---|---|
Seiten | 148-158 |
Seitenumfang | 11 |
Publikationsstatus | Veröffentlicht - 19 Aug. 1996 |
Extern publiziert | Ja |
Veranstaltung | Specification, Production, and Testing of Optical Components and Systems - Glasgow, UK Dauer: 13 Mai 1996 → 16 Mai 1996 |
Konferenz
Konferenz | Specification, Production, and Testing of Optical Components and Systems |
---|---|
Ort | Glasgow, UK |
Zeitraum | 13 Mai 1996 → 16 Mai 1996 |
Abstract
We report on the development of a laser calorimeter with sub ppm sensitivity. Besides the adaptation of the sample holder for low loss measurements, different ways of evaluating calorimetric data and methods for the detection and compensation of scatter irradiation effects as well as other signal distortions are discussed. As laser sources, an AR- laser and a Nd-YAG laser with frequency doubling option are employed for the measurements. The system is used for the characterization of different types of KTP crystals for frequency conversion. The results show a distinct polarization dependency of the absorption, throughout all crystals investigated.
ASJC Scopus Sachgebiete
- Werkstoffwissenschaften (insg.)
- Elektronische, optische und magnetische Materialien
- Physik und Astronomie (insg.)
- Physik der kondensierten Materie
- Informatik (insg.)
- Angewandte Informatik
- Mathematik (insg.)
- Angewandte Mathematik
- Ingenieurwesen (insg.)
- Elektrotechnik und Elektronik
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
1996. 148-158 Beitrag in Specification, Production, and Testing of Optical Components and Systems, Glasgow, UK.
Publikation: Konferenzbeitrag › Paper › Forschung › Peer-Review
}
TY - CONF
T1 - Calorimetric measurement of optical absorption and transmissivity with sub-ppm sensitivity
AU - Willamowski, Uwe
AU - Gross, Tobias
AU - Ristau, Detlev
AU - Welling, Herbert
PY - 1996/8/19
Y1 - 1996/8/19
N2 - We report on the development of a laser calorimeter with sub ppm sensitivity. Besides the adaptation of the sample holder for low loss measurements, different ways of evaluating calorimetric data and methods for the detection and compensation of scatter irradiation effects as well as other signal distortions are discussed. As laser sources, an AR- laser and a Nd-YAG laser with frequency doubling option are employed for the measurements. The system is used for the characterization of different types of KTP crystals for frequency conversion. The results show a distinct polarization dependency of the absorption, throughout all crystals investigated.
AB - We report on the development of a laser calorimeter with sub ppm sensitivity. Besides the adaptation of the sample holder for low loss measurements, different ways of evaluating calorimetric data and methods for the detection and compensation of scatter irradiation effects as well as other signal distortions are discussed. As laser sources, an AR- laser and a Nd-YAG laser with frequency doubling option are employed for the measurements. The system is used for the characterization of different types of KTP crystals for frequency conversion. The results show a distinct polarization dependency of the absorption, throughout all crystals investigated.
UR - http://www.scopus.com/inward/record.url?scp=0029745923&partnerID=8YFLogxK
U2 - 10.1117/12.246744
DO - 10.1117/12.246744
M3 - Paper
AN - SCOPUS:0029745923
SP - 148
EP - 158
T2 - Specification, Production, and Testing of Optical Components and Systems
Y2 - 13 May 1996 through 16 May 1996
ER -