Calibration routine for a telecentric stereo vision system considering affine mirror ambiguity

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Aufsatznummer054104
Seitenumfang21
FachzeitschriftOptical Engineering
Jahrgang59
Ausgabenummer5
PublikationsstatusVeröffentlicht - 26 Mai 2020

Abstract

A robust calibration approach for a telecentric stereo camera system for three-dimensional (3-D) surface measurements is presented, considering the effect of affine mirror ambiguity. By optimizing the parameters of a rigid body transformation between two marker planes and transforming the two-dimensional (2-D) data into one coordinate frame, a 3-D calibration object is obtained, avoiding high manufacturing costs. Based on the recent contributions in the literature, the calibration routine consists of an initial parameter estimation by affine reconstruction to provide good start values for a subsequent nonlinear stereo refinement based on a Levenberg-Marquardt optimization. To this end, the coordinates of the calibration target are reconstructed in 3-D using the Tomasi-Kanade factorization algorithm for affine cameras with Euclidean upgrade. The reconstructed result is not properly scaled and not unique due to affine ambiguity. In order to correct the erroneous scaling, the similarity transformation between one of the 2-D calibration plane points and the corresponding 3-D points is estimated. The resulting scaling factor is used to rescale the 3-D point data, which then allows in combination with the 2-D calibration plane data for a determination of the start values for the subsequent nonlinear stereo refinement. As the rigid body transformation between the 2-D calibration planes is also obtained, a possible affine mirror ambiguity in the affine reconstruction result can be robustly corrected. The calibration routine is validated by an experimental calibration and various plausibility tests. Due to the usage of a calibration object with metric information, the determined camera projection matrices allow for a triangulation of correctly scaled metric 3-D points without the need for an individual camera magnification determination.

ASJC Scopus Sachgebiete

Zitieren

Calibration routine for a telecentric stereo vision system considering affine mirror ambiguity. / Beermann, Rüdiger; Quentin, Lorenz; Kästner, Markus et al.
in: Optical Engineering, Jahrgang 59, Nr. 5, 054104, 26.05.2020.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Beermann R, Quentin L, Kästner M, Reithmeier E. Calibration routine for a telecentric stereo vision system considering affine mirror ambiguity. Optical Engineering. 2020 Mai 26;59(5):054104. doi: 10.1117/1.OE.59.5.054104
Download
@article{74801d65d7c1460db8c2af728eb7a2c3,
title = "Calibration routine for a telecentric stereo vision system considering affine mirror ambiguity",
abstract = "A robust calibration approach for a telecentric stereo camera system for three-dimensional (3-D) surface measurements is presented, considering the effect of affine mirror ambiguity. By optimizing the parameters of a rigid body transformation between two marker planes and transforming the two-dimensional (2-D) data into one coordinate frame, a 3-D calibration object is obtained, avoiding high manufacturing costs. Based on the recent contributions in the literature, the calibration routine consists of an initial parameter estimation by affine reconstruction to provide good start values for a subsequent nonlinear stereo refinement based on a Levenberg-Marquardt optimization. To this end, the coordinates of the calibration target are reconstructed in 3-D using the Tomasi-Kanade factorization algorithm for affine cameras with Euclidean upgrade. The reconstructed result is not properly scaled and not unique due to affine ambiguity. In order to correct the erroneous scaling, the similarity transformation between one of the 2-D calibration plane points and the corresponding 3-D points is estimated. The resulting scaling factor is used to rescale the 3-D point data, which then allows in combination with the 2-D calibration plane data for a determination of the start values for the subsequent nonlinear stereo refinement. As the rigid body transformation between the 2-D calibration planes is also obtained, a possible affine mirror ambiguity in the affine reconstruction result can be robustly corrected. The calibration routine is validated by an experimental calibration and various plausibility tests. Due to the usage of a calibration object with metric information, the determined camera projection matrices allow for a triangulation of correctly scaled metric 3-D points without the need for an individual camera magnification determination.",
keywords = "affine camera, affine mirror ambiguity, calibration, factorization algorithm, fringe projection, stereo camera pair, structured light, telecentric lens",
author = "R{\"u}diger Beermann and Lorenz Quentin and Markus K{\"a}stner and Eduard Reithmeier",
note = "Funding information: We want to thank the Deutsche Forschungsgemeinschaft (DFG) for funding subproject C5 Multiscale Geometry Inspection of Joining Zones as part of the Collaborative Research Centre (CRC) 1153 Process chain to produce hybrid high performance components by Tailored Forming (252662854). Also, we would like to thank Mr. T{\"o}berg for the valuable discussions on affine cameras and autocalibration. The authors declare no conflicts of interest.",
year = "2020",
month = may,
day = "26",
doi = "10.1117/1.OE.59.5.054104",
language = "English",
volume = "59",
journal = "Optical Engineering",
issn = "0091-3286",
publisher = "SPIE",
number = "5",

}

Download

TY - JOUR

T1 - Calibration routine for a telecentric stereo vision system considering affine mirror ambiguity

AU - Beermann, Rüdiger

AU - Quentin, Lorenz

AU - Kästner, Markus

AU - Reithmeier, Eduard

N1 - Funding information: We want to thank the Deutsche Forschungsgemeinschaft (DFG) for funding subproject C5 Multiscale Geometry Inspection of Joining Zones as part of the Collaborative Research Centre (CRC) 1153 Process chain to produce hybrid high performance components by Tailored Forming (252662854). Also, we would like to thank Mr. Töberg for the valuable discussions on affine cameras and autocalibration. The authors declare no conflicts of interest.

PY - 2020/5/26

Y1 - 2020/5/26

N2 - A robust calibration approach for a telecentric stereo camera system for three-dimensional (3-D) surface measurements is presented, considering the effect of affine mirror ambiguity. By optimizing the parameters of a rigid body transformation between two marker planes and transforming the two-dimensional (2-D) data into one coordinate frame, a 3-D calibration object is obtained, avoiding high manufacturing costs. Based on the recent contributions in the literature, the calibration routine consists of an initial parameter estimation by affine reconstruction to provide good start values for a subsequent nonlinear stereo refinement based on a Levenberg-Marquardt optimization. To this end, the coordinates of the calibration target are reconstructed in 3-D using the Tomasi-Kanade factorization algorithm for affine cameras with Euclidean upgrade. The reconstructed result is not properly scaled and not unique due to affine ambiguity. In order to correct the erroneous scaling, the similarity transformation between one of the 2-D calibration plane points and the corresponding 3-D points is estimated. The resulting scaling factor is used to rescale the 3-D point data, which then allows in combination with the 2-D calibration plane data for a determination of the start values for the subsequent nonlinear stereo refinement. As the rigid body transformation between the 2-D calibration planes is also obtained, a possible affine mirror ambiguity in the affine reconstruction result can be robustly corrected. The calibration routine is validated by an experimental calibration and various plausibility tests. Due to the usage of a calibration object with metric information, the determined camera projection matrices allow for a triangulation of correctly scaled metric 3-D points without the need for an individual camera magnification determination.

AB - A robust calibration approach for a telecentric stereo camera system for three-dimensional (3-D) surface measurements is presented, considering the effect of affine mirror ambiguity. By optimizing the parameters of a rigid body transformation between two marker planes and transforming the two-dimensional (2-D) data into one coordinate frame, a 3-D calibration object is obtained, avoiding high manufacturing costs. Based on the recent contributions in the literature, the calibration routine consists of an initial parameter estimation by affine reconstruction to provide good start values for a subsequent nonlinear stereo refinement based on a Levenberg-Marquardt optimization. To this end, the coordinates of the calibration target are reconstructed in 3-D using the Tomasi-Kanade factorization algorithm for affine cameras with Euclidean upgrade. The reconstructed result is not properly scaled and not unique due to affine ambiguity. In order to correct the erroneous scaling, the similarity transformation between one of the 2-D calibration plane points and the corresponding 3-D points is estimated. The resulting scaling factor is used to rescale the 3-D point data, which then allows in combination with the 2-D calibration plane data for a determination of the start values for the subsequent nonlinear stereo refinement. As the rigid body transformation between the 2-D calibration planes is also obtained, a possible affine mirror ambiguity in the affine reconstruction result can be robustly corrected. The calibration routine is validated by an experimental calibration and various plausibility tests. Due to the usage of a calibration object with metric information, the determined camera projection matrices allow for a triangulation of correctly scaled metric 3-D points without the need for an individual camera magnification determination.

KW - affine camera

KW - affine mirror ambiguity

KW - calibration

KW - factorization algorithm

KW - fringe projection

KW - stereo camera pair

KW - structured light

KW - telecentric lens

UR - http://www.scopus.com/inward/record.url?scp=85085939235&partnerID=8YFLogxK

U2 - 10.1117/1.OE.59.5.054104

DO - 10.1117/1.OE.59.5.054104

M3 - Article

AN - SCOPUS:85085939235

VL - 59

JO - Optical Engineering

JF - Optical Engineering

SN - 0091-3286

IS - 5

M1 - 054104

ER -

Von denselben Autoren