Calibration procedures for a 10.6 μm laser calorimeter

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Autoren

  • Michael Kennedy
  • Detlev Ristau
  • Gabriel Dumitru
  • Dan G. Sporea
  • Clementina A. Timus

Externe Organisationen

  • Laser Zentrum Hannover e.V. (LZH)
  • National Institute for Laser, Plasma and Radiation Physics
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Titel des SammelwerksFifth Conference in Optics
UntertitelROMOPTO '97
ErscheinungsortBellingham
Herausgeber (Verlag)SPIE
Seiten1083-1087
Seitenumfang5
ISBN (Print)0-8194-2857-4
PublikationsstatusVeröffentlicht - 2 Juli 1998
Extern publiziertJa
VeranstaltungROMOPTO '97: 5th Conference on Optics - Bucharest, Rumänien
Dauer: 9 Sept. 19979 Sept. 1997

Publikationsreihe

NameProceedings of SPIE - The International Society for Optical Engineering
Herausgeber (Verlag)SPIE
Band3405
ISSN (Print)0277-786X

Abstract

The paper presents the theoretical background of laser calorimetry as a method to investigate the absorptance of optical components, according to the recently adopted ISO Standard 11 551. An experimental set-up for optical absorption measurements, including a cw CO2 laser and a calorimetric chamber, is presented. The calibration of the laser calorimetric set-up is also described. The calibration involved several steps: laser power calibration, evaluation of chamber sensitivity, electrical calibration using electrically heated samples and optical calibration utilizing 100% absorptance samples. There were measured the conversion factors for the laser power and for the sample temperature; there were calculated over-all correction factors for the different substrates and they could be placed within ± 4% around their mean value.

ASJC Scopus Sachgebiete

Zitieren

Calibration procedures for a 10.6 μm laser calorimeter. / Kennedy, Michael; Ristau, Detlev; Dumitru, Gabriel et al.
Fifth Conference in Optics: ROMOPTO '97. Bellingham: SPIE, 1998. S. 1083-1087 (Proceedings of SPIE - The International Society for Optical Engineering; Band 3405).

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Kennedy, M, Ristau, D, Dumitru, G, Sporea, DG & Timus, CA 1998, Calibration procedures for a 10.6 μm laser calorimeter. in Fifth Conference in Optics: ROMOPTO '97. Proceedings of SPIE - The International Society for Optical Engineering, Bd. 3405, SPIE, Bellingham, S. 1083-1087, ROMOPTO '97: 5th Conference on Optics, Bucharest, Rumänien, 9 Sept. 1997. https://doi.org/10.1117/12.312718
Kennedy, M., Ristau, D., Dumitru, G., Sporea, D. G., & Timus, C. A. (1998). Calibration procedures for a 10.6 μm laser calorimeter. In Fifth Conference in Optics: ROMOPTO '97 (S. 1083-1087). (Proceedings of SPIE - The International Society for Optical Engineering; Band 3405). SPIE. https://doi.org/10.1117/12.312718
Kennedy M, Ristau D, Dumitru G, Sporea DG, Timus CA. Calibration procedures for a 10.6 μm laser calorimeter. in Fifth Conference in Optics: ROMOPTO '97. Bellingham: SPIE. 1998. S. 1083-1087. (Proceedings of SPIE - The International Society for Optical Engineering). doi: 10.1117/12.312718
Kennedy, Michael ; Ristau, Detlev ; Dumitru, Gabriel et al. / Calibration procedures for a 10.6 μm laser calorimeter. Fifth Conference in Optics: ROMOPTO '97. Bellingham : SPIE, 1998. S. 1083-1087 (Proceedings of SPIE - The International Society for Optical Engineering).
Download
@inproceedings{5d5b9d7be0124def9223352ac303fa16,
title = "Calibration procedures for a 10.6 μm laser calorimeter",
abstract = "The paper presents the theoretical background of laser calorimetry as a method to investigate the absorptance of optical components, according to the recently adopted ISO Standard 11 551. An experimental set-up for optical absorption measurements, including a cw CO2 laser and a calorimetric chamber, is presented. The calibration of the laser calorimetric set-up is also described. The calibration involved several steps: laser power calibration, evaluation of chamber sensitivity, electrical calibration using electrically heated samples and optical calibration utilizing 100% absorptance samples. There were measured the conversion factors for the laser power and for the sample temperature; there were calculated over-all correction factors for the different substrates and they could be placed within ± 4% around their mean value.",
keywords = "Absorptance, Calibration, ISO standard, Laser calorimetry, Laser optical component",
author = "Michael Kennedy and Detlev Ristau and Gabriel Dumitru and Sporea, {Dan G.} and Timus, {Clementina A.}",
year = "1998",
month = jul,
day = "2",
doi = "10.1117/12.312718",
language = "English",
isbn = "0-8194-2857-4",
series = "Proceedings of SPIE - The International Society for Optical Engineering",
publisher = "SPIE",
pages = "1083--1087",
booktitle = "Fifth Conference in Optics",
address = "United States",
note = "ROMOPTO '97: 5th Conference on Optics ; Conference date: 09-09-1997 Through 09-09-1997",

}

Download

TY - GEN

T1 - Calibration procedures for a 10.6 μm laser calorimeter

AU - Kennedy, Michael

AU - Ristau, Detlev

AU - Dumitru, Gabriel

AU - Sporea, Dan G.

AU - Timus, Clementina A.

PY - 1998/7/2

Y1 - 1998/7/2

N2 - The paper presents the theoretical background of laser calorimetry as a method to investigate the absorptance of optical components, according to the recently adopted ISO Standard 11 551. An experimental set-up for optical absorption measurements, including a cw CO2 laser and a calorimetric chamber, is presented. The calibration of the laser calorimetric set-up is also described. The calibration involved several steps: laser power calibration, evaluation of chamber sensitivity, electrical calibration using electrically heated samples and optical calibration utilizing 100% absorptance samples. There were measured the conversion factors for the laser power and for the sample temperature; there were calculated over-all correction factors for the different substrates and they could be placed within ± 4% around their mean value.

AB - The paper presents the theoretical background of laser calorimetry as a method to investigate the absorptance of optical components, according to the recently adopted ISO Standard 11 551. An experimental set-up for optical absorption measurements, including a cw CO2 laser and a calorimetric chamber, is presented. The calibration of the laser calorimetric set-up is also described. The calibration involved several steps: laser power calibration, evaluation of chamber sensitivity, electrical calibration using electrically heated samples and optical calibration utilizing 100% absorptance samples. There were measured the conversion factors for the laser power and for the sample temperature; there were calculated over-all correction factors for the different substrates and they could be placed within ± 4% around their mean value.

KW - Absorptance

KW - Calibration

KW - ISO standard

KW - Laser calorimetry

KW - Laser optical component

UR - http://www.scopus.com/inward/record.url?scp=58149240001&partnerID=8YFLogxK

U2 - 10.1117/12.312718

DO - 10.1117/12.312718

M3 - Conference contribution

AN - SCOPUS:58149240001

SN - 0-8194-2857-4

T3 - Proceedings of SPIE - The International Society for Optical Engineering

SP - 1083

EP - 1087

BT - Fifth Conference in Optics

PB - SPIE

CY - Bellingham

T2 - ROMOPTO '97: 5th Conference on Optics

Y2 - 9 September 1997 through 9 September 1997

ER -