Calibration of hybrid kinematics with a 1-DOF gauge

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Autorschaft

  • Berend Denkena
  • Hans-Christian Möhring
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Titel des SammelwerksLaser Metrology and Machine Performance VIII
Untertitel8th International Conference and Exhibition on Laser Metrology, Machine Tool, CMM and Robotic Performance, LAMDAMAP 2007
ErscheinungsortBedford
Seiten221-230
Seitenumfang10
ISBN (elektronisch)9780955308239
PublikationsstatusVeröffentlicht - 2007
VeranstaltungInternational Conference and Exhibition on Laser Metrology, Machine Tool, CMM & Robotic Performance - Cardiff, Großbritannien / Vereinigtes Königreich
Dauer: 25 Juni 200728 Juni 2007

Abstract

Calibration of complex hybrid kinematics machine tool structures is still a challenging task. Here a novel 5-axes hybrid kinematics milling machine for mould and die maintenance machining is regarded. Due to geometric, gravitational, dynamic and thermal error influences, the accuracy of such kinematics is limited and must be improved by suitable calibration strategies. The paper describes the analysis of the single linear axes by application of laser interferometers. The pose-dependency (pose = position and orientation of the tool) of the single-axis-accuracy becomes apparent. For calibration of the full structure a model based approach is chosen, which is described in the paper. A 1-DOF gauge is used to take measurements for parameter identification. Finally, calibration results are presented.

ASJC Scopus Sachgebiete

Zitieren

Calibration of hybrid kinematics with a 1-DOF gauge. / Denkena, Berend; Möhring, Hans-Christian.
Laser Metrology and Machine Performance VIII: 8th International Conference and Exhibition on Laser Metrology, Machine Tool, CMM and Robotic Performance, LAMDAMAP 2007. Bedford, 2007. S. 221-230.

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Denkena, B & Möhring, H-C 2007, Calibration of hybrid kinematics with a 1-DOF gauge. in Laser Metrology and Machine Performance VIII: 8th International Conference and Exhibition on Laser Metrology, Machine Tool, CMM and Robotic Performance, LAMDAMAP 2007. Bedford, S. 221-230, International Conference and Exhibition on Laser Metrology, Machine Tool, CMM & Robotic Performance, Cardiff, Großbritannien / Vereinigtes Königreich, 25 Juni 2007.
Denkena, B., & Möhring, H.-C. (2007). Calibration of hybrid kinematics with a 1-DOF gauge. In Laser Metrology and Machine Performance VIII: 8th International Conference and Exhibition on Laser Metrology, Machine Tool, CMM and Robotic Performance, LAMDAMAP 2007 (S. 221-230).
Denkena B, Möhring HC. Calibration of hybrid kinematics with a 1-DOF gauge. in Laser Metrology and Machine Performance VIII: 8th International Conference and Exhibition on Laser Metrology, Machine Tool, CMM and Robotic Performance, LAMDAMAP 2007. Bedford. 2007. S. 221-230
Denkena, Berend ; Möhring, Hans-Christian. / Calibration of hybrid kinematics with a 1-DOF gauge. Laser Metrology and Machine Performance VIII: 8th International Conference and Exhibition on Laser Metrology, Machine Tool, CMM and Robotic Performance, LAMDAMAP 2007. Bedford, 2007. S. 221-230
Download
@inproceedings{1d380529067540e194b03f600751c766,
title = "Calibration of hybrid kinematics with a 1-DOF gauge",
abstract = "Calibration of complex hybrid kinematics machine tool structures is still a challenging task. Here a novel 5-axes hybrid kinematics milling machine for mould and die maintenance machining is regarded. Due to geometric, gravitational, dynamic and thermal error influences, the accuracy of such kinematics is limited and must be improved by suitable calibration strategies. The paper describes the analysis of the single linear axes by application of laser interferometers. The pose-dependency (pose = position and orientation of the tool) of the single-axis-accuracy becomes apparent. For calibration of the full structure a model based approach is chosen, which is described in the paper. A 1-DOF gauge is used to take measurements for parameter identification. Finally, calibration results are presented.",
author = "Berend Denkena and Hans-Christian M{\"o}hring",
year = "2007",
language = "English",
pages = "221--230",
booktitle = "Laser Metrology and Machine Performance VIII",
note = "8th International Conference and Exhibition on Laser Metrology, Machine Tool, CMM and Robotic Performance, LAMDAMAP 2007 ; Conference date: 25-06-2007 Through 28-06-2007",

}

Download

TY - GEN

T1 - Calibration of hybrid kinematics with a 1-DOF gauge

AU - Denkena, Berend

AU - Möhring, Hans-Christian

PY - 2007

Y1 - 2007

N2 - Calibration of complex hybrid kinematics machine tool structures is still a challenging task. Here a novel 5-axes hybrid kinematics milling machine for mould and die maintenance machining is regarded. Due to geometric, gravitational, dynamic and thermal error influences, the accuracy of such kinematics is limited and must be improved by suitable calibration strategies. The paper describes the analysis of the single linear axes by application of laser interferometers. The pose-dependency (pose = position and orientation of the tool) of the single-axis-accuracy becomes apparent. For calibration of the full structure a model based approach is chosen, which is described in the paper. A 1-DOF gauge is used to take measurements for parameter identification. Finally, calibration results are presented.

AB - Calibration of complex hybrid kinematics machine tool structures is still a challenging task. Here a novel 5-axes hybrid kinematics milling machine for mould and die maintenance machining is regarded. Due to geometric, gravitational, dynamic and thermal error influences, the accuracy of such kinematics is limited and must be improved by suitable calibration strategies. The paper describes the analysis of the single linear axes by application of laser interferometers. The pose-dependency (pose = position and orientation of the tool) of the single-axis-accuracy becomes apparent. For calibration of the full structure a model based approach is chosen, which is described in the paper. A 1-DOF gauge is used to take measurements for parameter identification. Finally, calibration results are presented.

UR - http://www.scopus.com/inward/record.url?scp=84908884599&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:84908884599

SP - 221

EP - 230

BT - Laser Metrology and Machine Performance VIII

CY - Bedford

T2 - 8th International Conference and Exhibition on Laser Metrology, Machine Tool, CMM and Robotic Performance, LAMDAMAP 2007

Y2 - 25 June 2007 through 28 June 2007

ER -