Abstract
The development of enantioselective enzyme field effect transistors (EnFETs) for the detection of β-hydroxy acid esters and aromatic amino esters and their application in flow-injection analysis is described. The EnFETs were produced by immobilising the enzyme on the pH-sensitive gate surface of a pH-FET. The characteristics of the sensor signals and their dependence on certain process parameters, such as pH, buffer capacity and flow conditions in the medium being measured, were examined. Due to the short response time, the EnFETs are ideal for application in flow-injection analysis. The use of enantioselective EnFETs in on-line process monitoring is described.
ASJC Scopus Sachgebiete
- Chemie (insg.)
- Analytische Chemie
- Biochemie, Genetik und Molekularbiologie (insg.)
- Biochemie
- Umweltwissenschaften (insg.)
- Umweltchemie
- Chemie (insg.)
- Spektroskopie
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
in: Analytica chimica acta, Jahrgang 293, Nr. 3, 29.07.1994, S. 271-276.
Publikation: Beitrag in Fachzeitschrift › Artikel › Forschung › Peer-Review
}
TY - JOUR
T1 - Biosensors for enantioselective analysis
AU - Kullick, Thomas
AU - Ulber, Roland
AU - Meyer, Hartmut H.
AU - Scheper, Thomas
AU - Schügerl, Karl
PY - 1994/7/29
Y1 - 1994/7/29
N2 - The development of enantioselective enzyme field effect transistors (EnFETs) for the detection of β-hydroxy acid esters and aromatic amino esters and their application in flow-injection analysis is described. The EnFETs were produced by immobilising the enzyme on the pH-sensitive gate surface of a pH-FET. The characteristics of the sensor signals and their dependence on certain process parameters, such as pH, buffer capacity and flow conditions in the medium being measured, were examined. Due to the short response time, the EnFETs are ideal for application in flow-injection analysis. The use of enantioselective EnFETs in on-line process monitoring is described.
AB - The development of enantioselective enzyme field effect transistors (EnFETs) for the detection of β-hydroxy acid esters and aromatic amino esters and their application in flow-injection analysis is described. The EnFETs were produced by immobilising the enzyme on the pH-sensitive gate surface of a pH-FET. The characteristics of the sensor signals and their dependence on certain process parameters, such as pH, buffer capacity and flow conditions in the medium being measured, were examined. Due to the short response time, the EnFETs are ideal for application in flow-injection analysis. The use of enantioselective EnFETs in on-line process monitoring is described.
KW - Aromatic amino esters
KW - Biosensors
KW - Enantioselective analysis
KW - EnFETs
KW - Field effect transistors
KW - Flow injection
KW - β-Hydroxy acid esters
UR - http://www.scopus.com/inward/record.url?scp=0028290262&partnerID=8YFLogxK
U2 - 10.1016/0003-2670(94)85032-1
DO - 10.1016/0003-2670(94)85032-1
M3 - Article
AN - SCOPUS:0028290262
VL - 293
SP - 271
EP - 276
JO - Analytica chimica acta
JF - Analytica chimica acta
SN - 0003-2670
IS - 3
ER -