To achieve standardized and parallelized microscale protein purification, an automated purification system was developed and optimized using a pipetting robot for purifying large sets of proteins with Ni-NTA magnetic agarose beads. Recombinant hexahistidine-tagged proteins β-glucanase (Bgl-His) and esterase I of Pseudomonas fluorescens (PFE I) were tested on the system. High purity along with high coherence was achieved. The purification procedure can be applied to 96 samples simultaneously and only takes about 1/3 of the time required for purification conducted by hand. Due to the stability of the robot system, the consistency of the results is much better than the results achieved through manual purification. This rapid and reliable method is reproducible and applicable to high throughput screening of huge amounts of samples.

ASJC Scopus Sachgebiete

Zitieren

Automated Microscale His-tagged ProteinPurification Using Ni-NTA Magnetic Agarose Beads. / Meng, Jin; Walter, Johanna Gabriela; Kökpinar, Öznur et al.
in: Chemical Engineering and Technology, Jahrgang 31, Nr. 3, 28.02.2008, S. 463-468.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Meng, Jin ; Walter, Johanna Gabriela ; Kökpinar, Öznur et al. / Automated Microscale His-tagged ProteinPurification Using Ni-NTA Magnetic Agarose Beads. in: Chemical Engineering and Technology. 2008 ; Jahrgang 31, Nr. 3. S. 463-468.
Download
@article{172894170a954d88816529d1b84af9f7,
title = "Automated Microscale His-tagged ProteinPurification Using Ni-NTA Magnetic Agarose Beads",
abstract = "To achieve standardized and parallelized microscale protein purification, an automated purification system was developed and optimized using a pipetting robot for purifying large sets of proteins with Ni-NTA magnetic agarose beads. Recombinant hexahistidine-tagged proteins β-glucanase (Bgl-His) and esterase I of Pseudomonas fluorescens (PFE I) were tested on the system. High purity along with high coherence was achieved. The purification procedure can be applied to 96 samples simultaneously and only takes about 1/3 of the time required for purification conducted by hand. Due to the stability of the robot system, the consistency of the results is much better than the results achieved through manual purification. This rapid and reliable method is reproducible and applicable to high throughput screening of huge amounts of samples.",
keywords = "Magnetic agarose beads, Optimization, Protein purification",
author = "Jin Meng and Walter, {Johanna Gabriela} and {\"O}znur K{\"o}kpinar and Frank Stahl and Thomas Scheper",
year = "2008",
month = feb,
day = "28",
doi = "10.1002/ceat.200700429",
language = "English",
volume = "31",
pages = "463--468",
journal = "Chemical Engineering and Technology",
issn = "0930-7516",
publisher = "Wiley-VCH Verlag",
number = "3",

}

Download

TY - JOUR

T1 - Automated Microscale His-tagged ProteinPurification Using Ni-NTA Magnetic Agarose Beads

AU - Meng, Jin

AU - Walter, Johanna Gabriela

AU - Kökpinar, Öznur

AU - Stahl, Frank

AU - Scheper, Thomas

PY - 2008/2/28

Y1 - 2008/2/28

N2 - To achieve standardized and parallelized microscale protein purification, an automated purification system was developed and optimized using a pipetting robot for purifying large sets of proteins with Ni-NTA magnetic agarose beads. Recombinant hexahistidine-tagged proteins β-glucanase (Bgl-His) and esterase I of Pseudomonas fluorescens (PFE I) were tested on the system. High purity along with high coherence was achieved. The purification procedure can be applied to 96 samples simultaneously and only takes about 1/3 of the time required for purification conducted by hand. Due to the stability of the robot system, the consistency of the results is much better than the results achieved through manual purification. This rapid and reliable method is reproducible and applicable to high throughput screening of huge amounts of samples.

AB - To achieve standardized and parallelized microscale protein purification, an automated purification system was developed and optimized using a pipetting robot for purifying large sets of proteins with Ni-NTA magnetic agarose beads. Recombinant hexahistidine-tagged proteins β-glucanase (Bgl-His) and esterase I of Pseudomonas fluorescens (PFE I) were tested on the system. High purity along with high coherence was achieved. The purification procedure can be applied to 96 samples simultaneously and only takes about 1/3 of the time required for purification conducted by hand. Due to the stability of the robot system, the consistency of the results is much better than the results achieved through manual purification. This rapid and reliable method is reproducible and applicable to high throughput screening of huge amounts of samples.

KW - Magnetic agarose beads

KW - Optimization

KW - Protein purification

UR - http://www.scopus.com/inward/record.url?scp=41149086886&partnerID=8YFLogxK