Attoclock with counter-rotating bicircular laser fields

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

Organisationseinheiten

Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Aufsatznummer031402
Seitenumfang7
FachzeitschriftPhysical Review A
Jahrgang99
Ausgabenummer3
PublikationsstatusVeröffentlicht - 18 März 2019

Abstract

The attoclock technique which maps the emission time of a photoelectron to its detection angle is an important tool in strong-field physics. Previously, it was implemented only with circularly or elliptically polarized laser fields. Here, we show how counter-rotating bicircular laser fields can be used as an attoclock to investigate the ionization dynamics in quasilinear polarization. This is achieved by choosing the ratio of the two field strengths in a way such that the vector potential has aspects of the attoclock and time is mapped directly to the photoelectron momentum, but the shape of the electric field corresponds to approximately linear polarization during three intervals per optical cycle. We report momentum distributions calculated by solving the time-dependent Schrödinger equation for a model helium atom and obtain the mapping from photoelectron momentum to ionization time using a trajectory-free method. Unlike circular polarization where the time of maximal ionization rate typically deviates less than 5 attoseconds from the maximium of the electric field, we find positive ionization times of more than 10 attoseconds in the quasilinear case.

ASJC Scopus Sachgebiete

Zitieren

Attoclock with counter-rotating bicircular laser fields. / Eicke, Nicolas; Lein, Manfred.
in: Physical Review A, Jahrgang 99, Nr. 3, 031402, 18.03.2019.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Eicke N, Lein M. Attoclock with counter-rotating bicircular laser fields. Physical Review A. 2019 Mär 18;99(3):031402. doi: 10.1103/PhysRevA.99.031402
Download
@article{d09c170ad17a458294b9cd5a9f85a66b,
title = "Attoclock with counter-rotating bicircular laser fields",
abstract = "The attoclock technique which maps the emission time of a photoelectron to its detection angle is an important tool in strong-field physics. Previously, it was implemented only with circularly or elliptically polarized laser fields. Here, we show how counter-rotating bicircular laser fields can be used as an attoclock to investigate the ionization dynamics in quasilinear polarization. This is achieved by choosing the ratio of the two field strengths in a way such that the vector potential has aspects of the attoclock and time is mapped directly to the photoelectron momentum, but the shape of the electric field corresponds to approximately linear polarization during three intervals per optical cycle. We report momentum distributions calculated by solving the time-dependent Schr{\"o}dinger equation for a model helium atom and obtain the mapping from photoelectron momentum to ionization time using a trajectory-free method. Unlike circular polarization where the time of maximal ionization rate typically deviates less than 5 attoseconds from the maximium of the electric field, we find positive ionization times of more than 10 attoseconds in the quasilinear case.",
author = "Nicolas Eicke and Manfred Lein",
note = "Funding Information: This work has been supported by the Deutsche Forschungsgemeinschaft through the Priority Programme Quantum Dynamics in Tailored Intense Fields (QUTIF).",
year = "2019",
month = mar,
day = "18",
doi = "10.1103/PhysRevA.99.031402",
language = "English",
volume = "99",
journal = "Physical Review A",
issn = "2469-9926",
publisher = "American Physical Society",
number = "3",

}

Download

TY - JOUR

T1 - Attoclock with counter-rotating bicircular laser fields

AU - Eicke, Nicolas

AU - Lein, Manfred

N1 - Funding Information: This work has been supported by the Deutsche Forschungsgemeinschaft through the Priority Programme Quantum Dynamics in Tailored Intense Fields (QUTIF).

PY - 2019/3/18

Y1 - 2019/3/18

N2 - The attoclock technique which maps the emission time of a photoelectron to its detection angle is an important tool in strong-field physics. Previously, it was implemented only with circularly or elliptically polarized laser fields. Here, we show how counter-rotating bicircular laser fields can be used as an attoclock to investigate the ionization dynamics in quasilinear polarization. This is achieved by choosing the ratio of the two field strengths in a way such that the vector potential has aspects of the attoclock and time is mapped directly to the photoelectron momentum, but the shape of the electric field corresponds to approximately linear polarization during three intervals per optical cycle. We report momentum distributions calculated by solving the time-dependent Schrödinger equation for a model helium atom and obtain the mapping from photoelectron momentum to ionization time using a trajectory-free method. Unlike circular polarization where the time of maximal ionization rate typically deviates less than 5 attoseconds from the maximium of the electric field, we find positive ionization times of more than 10 attoseconds in the quasilinear case.

AB - The attoclock technique which maps the emission time of a photoelectron to its detection angle is an important tool in strong-field physics. Previously, it was implemented only with circularly or elliptically polarized laser fields. Here, we show how counter-rotating bicircular laser fields can be used as an attoclock to investigate the ionization dynamics in quasilinear polarization. This is achieved by choosing the ratio of the two field strengths in a way such that the vector potential has aspects of the attoclock and time is mapped directly to the photoelectron momentum, but the shape of the electric field corresponds to approximately linear polarization during three intervals per optical cycle. We report momentum distributions calculated by solving the time-dependent Schrödinger equation for a model helium atom and obtain the mapping from photoelectron momentum to ionization time using a trajectory-free method. Unlike circular polarization where the time of maximal ionization rate typically deviates less than 5 attoseconds from the maximium of the electric field, we find positive ionization times of more than 10 attoseconds in the quasilinear case.

UR - http://www.scopus.com/inward/record.url?scp=85063261894&partnerID=8YFLogxK

U2 - 10.1103/PhysRevA.99.031402

DO - 10.1103/PhysRevA.99.031402

M3 - Article

AN - SCOPUS:85063261894

VL - 99

JO - Physical Review A

JF - Physical Review A

SN - 2469-9926

IS - 3

M1 - 031402

ER -

Von denselben Autoren