Abstract
This paper presents the results of axial exhaust diffuser experiments using a twodimensional endoscopic Particle Image Velocimetry (PIV) system in order to visualize the complex unsteady diffuser flow, particularly its response onto the turbine operating conditions. In a series of experimental tests on a diffuser test rig which is equipped with a rotating spoke wheel as a turbulence generator, the swirl angle and the blade wakes are investigated in the diffuser flow. The laser light is lead into the test rig and the camera view is lead out of the test rig using an optical insert (endoscope). No additional windows must be installed in the outer casing. The endoscopic measurement set-up can even be applied for measurements in actual full-size exhaust diffusers. The PIV acquired data is needed for achieving a better understanding of the flow physics and for the validation of future computational fluid dynamics CFD calculations.
ASJC Scopus Sachgebiete
- Physik und Astronomie (insg.)
- Physik der kondensierten Materie
- Ingenieurwesen (insg.)
- Fahrzeugbau
- Ingenieurwesen (insg.)
- Werkstoffmechanik
- Ingenieurwesen (insg.)
- Maschinenbau
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
9th European Conference on Turbomachinery: Fluid Dynamics and Thermodynamics, ETC 2011 - Conference Proceedings. Hrsg. / M. Sen; M. Manna; T. Arts; G. Bois. American Society of Mechanical Engineers(ASME), 2011. S. 663-672 (9th European Conference on Turbomachinery: Fluid Dynamics and Thermodynamics, ETC 2011 - Conference Proceedings; Band 1).
Publikation: Beitrag in Buch/Bericht/Sammelwerk/Konferenzband › Aufsatz in Konferenzband › Forschung › Peer-Review
}
TY - GEN
T1 - Application of endoscopic PIV to the interaction between turbine and exhaust diffuser
AU - Opilat, Victor
AU - Seume, Joerg R.
PY - 2011
Y1 - 2011
N2 - This paper presents the results of axial exhaust diffuser experiments using a twodimensional endoscopic Particle Image Velocimetry (PIV) system in order to visualize the complex unsteady diffuser flow, particularly its response onto the turbine operating conditions. In a series of experimental tests on a diffuser test rig which is equipped with a rotating spoke wheel as a turbulence generator, the swirl angle and the blade wakes are investigated in the diffuser flow. The laser light is lead into the test rig and the camera view is lead out of the test rig using an optical insert (endoscope). No additional windows must be installed in the outer casing. The endoscopic measurement set-up can even be applied for measurements in actual full-size exhaust diffusers. The PIV acquired data is needed for achieving a better understanding of the flow physics and for the validation of future computational fluid dynamics CFD calculations.
AB - This paper presents the results of axial exhaust diffuser experiments using a twodimensional endoscopic Particle Image Velocimetry (PIV) system in order to visualize the complex unsteady diffuser flow, particularly its response onto the turbine operating conditions. In a series of experimental tests on a diffuser test rig which is equipped with a rotating spoke wheel as a turbulence generator, the swirl angle and the blade wakes are investigated in the diffuser flow. The laser light is lead into the test rig and the camera view is lead out of the test rig using an optical insert (endoscope). No additional windows must be installed in the outer casing. The endoscopic measurement set-up can even be applied for measurements in actual full-size exhaust diffusers. The PIV acquired data is needed for achieving a better understanding of the flow physics and for the validation of future computational fluid dynamics CFD calculations.
UR - http://www.scopus.com/inward/record.url?scp=84915805710&partnerID=8YFLogxK
M3 - Conference contribution
AN - SCOPUS:84915805710
T3 - 9th European Conference on Turbomachinery: Fluid Dynamics and Thermodynamics, ETC 2011 - Conference Proceedings
SP - 663
EP - 672
BT - 9th European Conference on Turbomachinery
A2 - Sen, M.
A2 - Manna, M.
A2 - Arts, T.
A2 - Bois, G.
PB - American Society of Mechanical Engineers(ASME)
T2 - 9th European Conference on Turbomachinery: Fluid Dynamics and Thermodynamics, ETC 2011
Y2 - 21 March 2011 through 25 March 2011
ER -