Application of a Parallelizable Perfusion Bioreactor for Physiologic 3D Cell Culture

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

  • Dominik Egger
  • Sarah Spitz
  • Monica Fischer
  • Stephan Handschuh
  • Martin Glösmann
  • Benedikt Friemert
  • Monika Egerbacher
  • Cornelia Kasper

Externe Organisationen

  • Universität für Bodenkultur Wien (BOKU)
  • Bundeswehrkrankenhaus Ulm
  • Veterinärmedizinische Universität Wien
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)316-326
Seitenumfang11
FachzeitschriftCELLS TISSUES ORGANS
Jahrgang203
Ausgabenummer5
PublikationsstatusVeröffentlicht - 15 Mai 2017
Extern publiziertJa

Abstract

It is crucial but challenging to keep physiologic conditions during the cultivation of 3D cell scaffold constructs for the optimization of 3D cell culture processes. Therefore, we demonstrate the benefits of a recently developed miniaturized perfusion bioreactor together with a specialized incubator system that allows for the cultivation of multiple samples while screening different conditions. Hence, a decellularized bone matrix was tested towards its suitability for 3D osteogenic differentiation under flow perfusion conditions. Subsequently, physiologic shear stress and hydrostatic pressure (HP) conditions were optimized for osteogenic differentiation of human mesenchymal stem cells (MSCs). X-ray computed microtomography and scanning electron microscopy (SEM) revealed a closed cell layer covering the entire matrix. Osteogenic differentiation assessed by alkaline phosphatase activity and SEM was found to be increased in all dynamic conditions. Furthermore, screening of different fluid shear stress (FSS) conditions revealed 1.5 mL/min (equivalent to ∼10 mPa shear stress) to be optimal. However, no distinct effect of HP compared to flow perfusion without HP on osteogenic differentiation was observed. Notably, throughout all experiments, cells cultivated under FSS or HP conditions displayed increased osteogenic differentiation, which underlines the importance of physiologic conditions. In conclusion, the bioreactor system was used for biomaterial testing and to develop and optimize a 3D cell culture process for the osteogenic differentiation of MSCs. Due to its versatility and higher throughput efficiency, we hypothesize that this bioreactor/incubator system will advance the development and optimization of a variety of 3D cell culture processes.

ASJC Scopus Sachgebiete

Zitieren

Application of a Parallelizable Perfusion Bioreactor for Physiologic 3D Cell Culture. / Egger, Dominik; Spitz, Sarah; Fischer, Monica et al.
in: CELLS TISSUES ORGANS, Jahrgang 203, Nr. 5, 15.05.2017, S. 316-326.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Egger, D, Spitz, S, Fischer, M, Handschuh, S, Glösmann, M, Friemert, B, Egerbacher, M & Kasper, C 2017, 'Application of a Parallelizable Perfusion Bioreactor for Physiologic 3D Cell Culture', CELLS TISSUES ORGANS, Jg. 203, Nr. 5, S. 316-326. https://doi.org/10.1159/000457792
Egger, D., Spitz, S., Fischer, M., Handschuh, S., Glösmann, M., Friemert, B., Egerbacher, M., & Kasper, C. (2017). Application of a Parallelizable Perfusion Bioreactor for Physiologic 3D Cell Culture. CELLS TISSUES ORGANS, 203(5), 316-326. https://doi.org/10.1159/000457792
Egger D, Spitz S, Fischer M, Handschuh S, Glösmann M, Friemert B et al. Application of a Parallelizable Perfusion Bioreactor for Physiologic 3D Cell Culture. CELLS TISSUES ORGANS. 2017 Mai 15;203(5):316-326. doi: 10.1159/000457792
Egger, Dominik ; Spitz, Sarah ; Fischer, Monica et al. / Application of a Parallelizable Perfusion Bioreactor for Physiologic 3D Cell Culture. in: CELLS TISSUES ORGANS. 2017 ; Jahrgang 203, Nr. 5. S. 316-326.
Download
@article{43556c840cab4fdd9c62fa97510c9821,
title = "Application of a Parallelizable Perfusion Bioreactor for Physiologic 3D Cell Culture",
abstract = "It is crucial but challenging to keep physiologic conditions during the cultivation of 3D cell scaffold constructs for the optimization of 3D cell culture processes. Therefore, we demonstrate the benefits of a recently developed miniaturized perfusion bioreactor together with a specialized incubator system that allows for the cultivation of multiple samples while screening different conditions. Hence, a decellularized bone matrix was tested towards its suitability for 3D osteogenic differentiation under flow perfusion conditions. Subsequently, physiologic shear stress and hydrostatic pressure (HP) conditions were optimized for osteogenic differentiation of human mesenchymal stem cells (MSCs). X-ray computed microtomography and scanning electron microscopy (SEM) revealed a closed cell layer covering the entire matrix. Osteogenic differentiation assessed by alkaline phosphatase activity and SEM was found to be increased in all dynamic conditions. Furthermore, screening of different fluid shear stress (FSS) conditions revealed 1.5 mL/min (equivalent to ∼10 mPa shear stress) to be optimal. However, no distinct effect of HP compared to flow perfusion without HP on osteogenic differentiation was observed. Notably, throughout all experiments, cells cultivated under FSS or HP conditions displayed increased osteogenic differentiation, which underlines the importance of physiologic conditions. In conclusion, the bioreactor system was used for biomaterial testing and to develop and optimize a 3D cell culture process for the osteogenic differentiation of MSCs. Due to its versatility and higher throughput efficiency, we hypothesize that this bioreactor/incubator system will advance the development and optimization of a variety of 3D cell culture processes.",
keywords = "3D cell culture, Dynamic cultivation, Fluid shear stress, Hydrostatic pressure, Perfusion bioreactor system",
author = "Dominik Egger and Sarah Spitz and Monica Fischer and Stephan Handschuh and Martin Gl{\"o}smann and Benedikt Friemert and Monika Egerbacher and Cornelia Kasper",
year = "2017",
month = may,
day = "15",
doi = "10.1159/000457792",
language = "English",
volume = "203",
pages = "316--326",
journal = "CELLS TISSUES ORGANS",
issn = "1422-6405",
publisher = "S. Karger AG",
number = "5",

}

Download

TY - JOUR

T1 - Application of a Parallelizable Perfusion Bioreactor for Physiologic 3D Cell Culture

AU - Egger, Dominik

AU - Spitz, Sarah

AU - Fischer, Monica

AU - Handschuh, Stephan

AU - Glösmann, Martin

AU - Friemert, Benedikt

AU - Egerbacher, Monika

AU - Kasper, Cornelia

PY - 2017/5/15

Y1 - 2017/5/15

N2 - It is crucial but challenging to keep physiologic conditions during the cultivation of 3D cell scaffold constructs for the optimization of 3D cell culture processes. Therefore, we demonstrate the benefits of a recently developed miniaturized perfusion bioreactor together with a specialized incubator system that allows for the cultivation of multiple samples while screening different conditions. Hence, a decellularized bone matrix was tested towards its suitability for 3D osteogenic differentiation under flow perfusion conditions. Subsequently, physiologic shear stress and hydrostatic pressure (HP) conditions were optimized for osteogenic differentiation of human mesenchymal stem cells (MSCs). X-ray computed microtomography and scanning electron microscopy (SEM) revealed a closed cell layer covering the entire matrix. Osteogenic differentiation assessed by alkaline phosphatase activity and SEM was found to be increased in all dynamic conditions. Furthermore, screening of different fluid shear stress (FSS) conditions revealed 1.5 mL/min (equivalent to ∼10 mPa shear stress) to be optimal. However, no distinct effect of HP compared to flow perfusion without HP on osteogenic differentiation was observed. Notably, throughout all experiments, cells cultivated under FSS or HP conditions displayed increased osteogenic differentiation, which underlines the importance of physiologic conditions. In conclusion, the bioreactor system was used for biomaterial testing and to develop and optimize a 3D cell culture process for the osteogenic differentiation of MSCs. Due to its versatility and higher throughput efficiency, we hypothesize that this bioreactor/incubator system will advance the development and optimization of a variety of 3D cell culture processes.

AB - It is crucial but challenging to keep physiologic conditions during the cultivation of 3D cell scaffold constructs for the optimization of 3D cell culture processes. Therefore, we demonstrate the benefits of a recently developed miniaturized perfusion bioreactor together with a specialized incubator system that allows for the cultivation of multiple samples while screening different conditions. Hence, a decellularized bone matrix was tested towards its suitability for 3D osteogenic differentiation under flow perfusion conditions. Subsequently, physiologic shear stress and hydrostatic pressure (HP) conditions were optimized for osteogenic differentiation of human mesenchymal stem cells (MSCs). X-ray computed microtomography and scanning electron microscopy (SEM) revealed a closed cell layer covering the entire matrix. Osteogenic differentiation assessed by alkaline phosphatase activity and SEM was found to be increased in all dynamic conditions. Furthermore, screening of different fluid shear stress (FSS) conditions revealed 1.5 mL/min (equivalent to ∼10 mPa shear stress) to be optimal. However, no distinct effect of HP compared to flow perfusion without HP on osteogenic differentiation was observed. Notably, throughout all experiments, cells cultivated under FSS or HP conditions displayed increased osteogenic differentiation, which underlines the importance of physiologic conditions. In conclusion, the bioreactor system was used for biomaterial testing and to develop and optimize a 3D cell culture process for the osteogenic differentiation of MSCs. Due to its versatility and higher throughput efficiency, we hypothesize that this bioreactor/incubator system will advance the development and optimization of a variety of 3D cell culture processes.

KW - 3D cell culture

KW - Dynamic cultivation

KW - Fluid shear stress

KW - Hydrostatic pressure

KW - Perfusion bioreactor system

UR - http://www.scopus.com/inward/record.url?scp=85015665793&partnerID=8YFLogxK

U2 - 10.1159/000457792

DO - 10.1159/000457792

M3 - Article

C2 - 28291964

AN - SCOPUS:85015665793

VL - 203

SP - 316

EP - 326

JO - CELLS TISSUES ORGANS

JF - CELLS TISSUES ORGANS

SN - 1422-6405

IS - 5

ER -

Von denselben Autoren