Application of a Nonradioactive Pulsed Electron Source for Ion Mobility Spectrometry

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

Organisationseinheiten

Externe Organisationen

  • German University in Cairo
  • Drägerwerk AG Co. KGaA
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)3756-3763
Seitenumfang8
FachzeitschriftAnalytical chemistry
Jahrgang82
Ausgabenummer9
PublikationsstatusVeröffentlicht - 30 März 2010

Abstract

Ion mobility spectrometry (IMS) is a well-known method for detecting hazardous compounds in air. Typical applications are the detection of chemical warfare agents, highly toxic industrial compounds, explosives, and drugs of abuse. Detection limits in the low part per billion range, fast response times, and simple instrumentation make this technique more and more popular. Common ion mobility spectrometers work by employing a radioactive source to provide electrons with high energy to ionize analytes in a series of chemical reactions. General security as well as regulatory concerns related to radioactivity result in the need for a different ionization source which on the other hand produces ions in a similar manner as a radioactive source since the ion chemistry is well-known. Here we show the application of a novel nonradioactive source that produces spectra similar to those obtained with radioactive tritium sources. Using this source in a pulsed mode offers the additional advantage of selecting certain analytes by their recombination time and thus significantly increasing the selectivity. The successful isolation of a target signal in the presence of contaminants using a pulsed electron beam or more precisely the difference in recombination times will be demonstrated for the case of dimethyl- methylphosphonate (DMMP) showing the potential of this source to reduce the possibility for false-positive detection of corresponding chemical warfare agents (CWA) by IMS.

ASJC Scopus Sachgebiete

Zitieren

Application of a Nonradioactive Pulsed Electron Source for Ion Mobility Spectrometry. / Gunzer, Frank; Zimmermann, Stefan; Baether, Wolfgang.
in: Analytical chemistry, Jahrgang 82, Nr. 9, 30.03.2010, S. 3756-3763.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Gunzer, Frank ; Zimmermann, Stefan ; Baether, Wolfgang. / Application of a Nonradioactive Pulsed Electron Source for Ion Mobility Spectrometry. in: Analytical chemistry. 2010 ; Jahrgang 82, Nr. 9. S. 3756-3763.
Download
@article{b0cffd335ebf4c23b508a9acbb4cd132,
title = "Application of a Nonradioactive Pulsed Electron Source for Ion Mobility Spectrometry",
abstract = "Ion mobility spectrometry (IMS) is a well-known method for detecting hazardous compounds in air. Typical applications are the detection of chemical warfare agents, highly toxic industrial compounds, explosives, and drugs of abuse. Detection limits in the low part per billion range, fast response times, and simple instrumentation make this technique more and more popular. Common ion mobility spectrometers work by employing a radioactive source to provide electrons with high energy to ionize analytes in a series of chemical reactions. General security as well as regulatory concerns related to radioactivity result in the need for a different ionization source which on the other hand produces ions in a similar manner as a radioactive source since the ion chemistry is well-known. Here we show the application of a novel nonradioactive source that produces spectra similar to those obtained with radioactive tritium sources. Using this source in a pulsed mode offers the additional advantage of selecting certain analytes by their recombination time and thus significantly increasing the selectivity. The successful isolation of a target signal in the presence of contaminants using a pulsed electron beam or more precisely the difference in recombination times will be demonstrated for the case of dimethyl- methylphosphonate (DMMP) showing the potential of this source to reduce the possibility for false-positive detection of corresponding chemical warfare agents (CWA) by IMS.",
author = "Frank Gunzer and Stefan Zimmermann and Wolfgang Baether",
year = "2010",
month = mar,
day = "30",
doi = "10.1021/ac100166m",
language = "English",
volume = "82",
pages = "3756--3763",
journal = "Analytical chemistry",
issn = "0003-2700",
publisher = "American Chemical Society",
number = "9",

}

Download

TY - JOUR

T1 - Application of a Nonradioactive Pulsed Electron Source for Ion Mobility Spectrometry

AU - Gunzer, Frank

AU - Zimmermann, Stefan

AU - Baether, Wolfgang

PY - 2010/3/30

Y1 - 2010/3/30

N2 - Ion mobility spectrometry (IMS) is a well-known method for detecting hazardous compounds in air. Typical applications are the detection of chemical warfare agents, highly toxic industrial compounds, explosives, and drugs of abuse. Detection limits in the low part per billion range, fast response times, and simple instrumentation make this technique more and more popular. Common ion mobility spectrometers work by employing a radioactive source to provide electrons with high energy to ionize analytes in a series of chemical reactions. General security as well as regulatory concerns related to radioactivity result in the need for a different ionization source which on the other hand produces ions in a similar manner as a radioactive source since the ion chemistry is well-known. Here we show the application of a novel nonradioactive source that produces spectra similar to those obtained with radioactive tritium sources. Using this source in a pulsed mode offers the additional advantage of selecting certain analytes by their recombination time and thus significantly increasing the selectivity. The successful isolation of a target signal in the presence of contaminants using a pulsed electron beam or more precisely the difference in recombination times will be demonstrated for the case of dimethyl- methylphosphonate (DMMP) showing the potential of this source to reduce the possibility for false-positive detection of corresponding chemical warfare agents (CWA) by IMS.

AB - Ion mobility spectrometry (IMS) is a well-known method for detecting hazardous compounds in air. Typical applications are the detection of chemical warfare agents, highly toxic industrial compounds, explosives, and drugs of abuse. Detection limits in the low part per billion range, fast response times, and simple instrumentation make this technique more and more popular. Common ion mobility spectrometers work by employing a radioactive source to provide electrons with high energy to ionize analytes in a series of chemical reactions. General security as well as regulatory concerns related to radioactivity result in the need for a different ionization source which on the other hand produces ions in a similar manner as a radioactive source since the ion chemistry is well-known. Here we show the application of a novel nonradioactive source that produces spectra similar to those obtained with radioactive tritium sources. Using this source in a pulsed mode offers the additional advantage of selecting certain analytes by their recombination time and thus significantly increasing the selectivity. The successful isolation of a target signal in the presence of contaminants using a pulsed electron beam or more precisely the difference in recombination times will be demonstrated for the case of dimethyl- methylphosphonate (DMMP) showing the potential of this source to reduce the possibility for false-positive detection of corresponding chemical warfare agents (CWA) by IMS.

UR - http://www.scopus.com/inward/record.url?scp=77951867484&partnerID=8YFLogxK

U2 - 10.1021/ac100166m

DO - 10.1021/ac100166m

M3 - Article

AN - SCOPUS:77951867484

VL - 82

SP - 3756

EP - 3763

JO - Analytical chemistry

JF - Analytical chemistry

SN - 0003-2700

IS - 9

ER -