Abstract
This paper presents the application of an analytical method for the computation of the transfer functions of transformers. The method used shows in contrast to other procedures no principal limits in the considered frequency range and calculates iteratively both the structure of the transfer function as well as the system parameters. For this reason, the transfer function of any transformer can be computed automatically, thus enabling the presented method to be the base for a diagnosis of the operating behaviour of the devices. The suitability of the applied method is shown by a comparison of measured frequency responses and calculated transfer functions of a distribution transformer as well as of a power transformer.
ASJC Scopus Sachgebiete
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
1998. 787-790 Beitrag in 1998 International Symposium on Electrical Insulating Materials, Toyohashi, Jpn.
Publikation: Konferenzbeitrag › Paper › Forschung › Peer-Review
}
TY - CONF
T1 - Analytical computation of the transfer functions of transformers
AU - Wenzel, D.
AU - Borsi, H.
AU - Gockenbach, Ernst
N1 - Copyright: Copyright 2004 Elsevier Science B.V., Amsterdam. All rights reserved.
PY - 1998
Y1 - 1998
N2 - This paper presents the application of an analytical method for the computation of the transfer functions of transformers. The method used shows in contrast to other procedures no principal limits in the considered frequency range and calculates iteratively both the structure of the transfer function as well as the system parameters. For this reason, the transfer function of any transformer can be computed automatically, thus enabling the presented method to be the base for a diagnosis of the operating behaviour of the devices. The suitability of the applied method is shown by a comparison of measured frequency responses and calculated transfer functions of a distribution transformer as well as of a power transformer.
AB - This paper presents the application of an analytical method for the computation of the transfer functions of transformers. The method used shows in contrast to other procedures no principal limits in the considered frequency range and calculates iteratively both the structure of the transfer function as well as the system parameters. For this reason, the transfer function of any transformer can be computed automatically, thus enabling the presented method to be the base for a diagnosis of the operating behaviour of the devices. The suitability of the applied method is shown by a comparison of measured frequency responses and calculated transfer functions of a distribution transformer as well as of a power transformer.
UR - http://www.scopus.com/inward/record.url?scp=0032309810&partnerID=8YFLogxK
M3 - Paper
AN - SCOPUS:0032309810
SP - 787
EP - 790
T2 - 1998 International Symposium on Electrical Insulating Materials
Y2 - 27 September 1998 through 30 September 1998
ER -