Abstract

The paper reports on sensorless control methods for permanent magnet machine drives at low speed, analysing the most promising approaches for sensorless control at low speed, which are the INFORM (indirect flux detection by online reactance measurement) method and the high frequency injection (HF Injection). In order to compare both methods, they are derived using the same voltage equation. This context is often missing in literature. Furthermore, the effect of the rotor position estimation on the overall motor control is characterised. This is necessary to set limits for stable operation areas of the motor. Theoretical foundations are substantiated by simulations.

ASJC Scopus Sachgebiete

Zitieren

Analysis and comparison of sensorless control methods for permanent magnet machine drives at low speed. / Wiedmann, Karsten; Mertens, Axel.
in: Acta Technica CSAV (Ceskoslovensk Akademie Ved), Jahrgang 54, Nr. 1, 2009, S. 19-33.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Wiedmann, K & Mertens, A 2009, 'Analysis and comparison of sensorless control methods for permanent magnet machine drives at low speed', Acta Technica CSAV (Ceskoslovensk Akademie Ved), Jg. 54, Nr. 1, S. 19-33.
Wiedmann, K., & Mertens, A. (2009). Analysis and comparison of sensorless control methods for permanent magnet machine drives at low speed. Acta Technica CSAV (Ceskoslovensk Akademie Ved), 54(1), 19-33.
Wiedmann K, Mertens A. Analysis and comparison of sensorless control methods for permanent magnet machine drives at low speed. Acta Technica CSAV (Ceskoslovensk Akademie Ved). 2009;54(1):19-33.
Wiedmann, Karsten ; Mertens, Axel. / Analysis and comparison of sensorless control methods for permanent magnet machine drives at low speed. in: Acta Technica CSAV (Ceskoslovensk Akademie Ved). 2009 ; Jahrgang 54, Nr. 1. S. 19-33.
Download
@article{36886d157bf048b18cc2899f4fa97640,
title = "Analysis and comparison of sensorless control methods for permanent magnet machine drives at low speed",
abstract = "The paper reports on sensorless control methods for permanent magnet machine drives at low speed, analysing the most promising approaches for sensorless control at low speed, which are the INFORM (indirect flux detection by online reactance measurement) method and the high frequency injection (HF Injection). In order to compare both methods, they are derived using the same voltage equation. This context is often missing in literature. Furthermore, the effect of the rotor position estimation on the overall motor control is characterised. This is necessary to set limits for stable operation areas of the motor. Theoretical foundations are substantiated by simulations.",
keywords = "Motion control, Permanent-magnet motors, Sensorless control",
author = "Karsten Wiedmann and Axel Mertens",
year = "2009",
language = "English",
volume = "54",
pages = "19--33",
number = "1",

}

Download

TY - JOUR

T1 - Analysis and comparison of sensorless control methods for permanent magnet machine drives at low speed

AU - Wiedmann, Karsten

AU - Mertens, Axel

PY - 2009

Y1 - 2009

N2 - The paper reports on sensorless control methods for permanent magnet machine drives at low speed, analysing the most promising approaches for sensorless control at low speed, which are the INFORM (indirect flux detection by online reactance measurement) method and the high frequency injection (HF Injection). In order to compare both methods, they are derived using the same voltage equation. This context is often missing in literature. Furthermore, the effect of the rotor position estimation on the overall motor control is characterised. This is necessary to set limits for stable operation areas of the motor. Theoretical foundations are substantiated by simulations.

AB - The paper reports on sensorless control methods for permanent magnet machine drives at low speed, analysing the most promising approaches for sensorless control at low speed, which are the INFORM (indirect flux detection by online reactance measurement) method and the high frequency injection (HF Injection). In order to compare both methods, they are derived using the same voltage equation. This context is often missing in literature. Furthermore, the effect of the rotor position estimation on the overall motor control is characterised. This is necessary to set limits for stable operation areas of the motor. Theoretical foundations are substantiated by simulations.

KW - Motion control

KW - Permanent-magnet motors

KW - Sensorless control

UR - http://www.scopus.com/inward/record.url?scp=65349110892&partnerID=8YFLogxK