An optimized geometry for a micro Penning-trap mass spectrometer based on interconnected ions

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

  • J. M. Cornejo
  • M. J. Gutiérrez
  • E. Ruiz
  • A. Bautista-Salvador
  • C. Ospelkaus
  • S. Stahl
  • D. Rodríguez

Organisationseinheiten

Externe Organisationen

  • University of Granada
  • Physikalisch-Technische Bundesanstalt (PTB)
  • Stahl-Electronics
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)22-30
Seitenumfang9
FachzeitschriftInternational Journal of Mass Spectrometry
Jahrgang410
Frühes Online-Datum14 Okt. 2016
PublikationsstatusVeröffentlicht - 20 Nov. 2016

ASJC Scopus Sachgebiete

Zitieren

An optimized geometry for a micro Penning-trap mass spectrometer based on interconnected ions. / Cornejo, J. M.; Gutiérrez, M. J.; Ruiz, E. et al.
in: International Journal of Mass Spectrometry, Jahrgang 410, 20.11.2016, S. 22-30.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Cornejo JM, Gutiérrez MJ, Ruiz E, Bautista-Salvador A, Ospelkaus C, Stahl S et al. An optimized geometry for a micro Penning-trap mass spectrometer based on interconnected ions. International Journal of Mass Spectrometry. 2016 Nov 20;410:22-30. Epub 2016 Okt 14. doi: 10.1016/j.ijms.2016.10.010
Cornejo, J. M. ; Gutiérrez, M. J. ; Ruiz, E. et al. / An optimized geometry for a micro Penning-trap mass spectrometer based on interconnected ions. in: International Journal of Mass Spectrometry. 2016 ; Jahrgang 410. S. 22-30.
Download
@article{f6363d5e8a564df18270ea0fd66f3fb4,
title = "An optimized geometry for a micro Penning-trap mass spectrometer based on interconnected ions",
keywords = "Induced image current, Ion traps, Ion-ion coupling, Laser cooling, Penning-trap mass spectrometry",
author = "Cornejo, {J. M.} and Guti{\'e}rrez, {M. J.} and E. Ruiz and A. Bautista-Salvador and C. Ospelkaus and S. Stahl and D. Rodr{\'i}guez",
note = "Funding information: We acknowledge support from the European Research Council (ERC StG contract no 278648-TRAPSENSOR) and from the Spanish Ministry of Economy and Competitiveness through the projects FPA2012-32076, FPA2015-67694-P and UNGR10-1E-501. We also acknowledge support from ERC StG “QLEDS” and PTB clean room facility staff. We warmly thank Jos{\'e} Verd{\'u} and Pierre Delahaye for providing the programs they developed for their traps to be used for the calculations presented here. Part of the work of M.J.G. was supported by a fellowship on initiation to research provided by the so-called “Plan Propio” funded by the Vice-Rectorate of Scientific Policy and Research at the University of Granada.",
year = "2016",
month = nov,
day = "20",
doi = "10.1016/j.ijms.2016.10.010",
language = "English",
volume = "410",
pages = "22--30",
journal = "International Journal of Mass Spectrometry",
issn = "1387-3806",
publisher = "Elsevier",

}

Download

TY - JOUR

T1 - An optimized geometry for a micro Penning-trap mass spectrometer based on interconnected ions

AU - Cornejo, J. M.

AU - Gutiérrez, M. J.

AU - Ruiz, E.

AU - Bautista-Salvador, A.

AU - Ospelkaus, C.

AU - Stahl, S.

AU - Rodríguez, D.

N1 - Funding information: We acknowledge support from the European Research Council (ERC StG contract no 278648-TRAPSENSOR) and from the Spanish Ministry of Economy and Competitiveness through the projects FPA2012-32076, FPA2015-67694-P and UNGR10-1E-501. We also acknowledge support from ERC StG “QLEDS” and PTB clean room facility staff. We warmly thank José Verdú and Pierre Delahaye for providing the programs they developed for their traps to be used for the calculations presented here. Part of the work of M.J.G. was supported by a fellowship on initiation to research provided by the so-called “Plan Propio” funded by the Vice-Rectorate of Scientific Policy and Research at the University of Granada.

PY - 2016/11/20

Y1 - 2016/11/20

KW - Induced image current

KW - Ion traps

KW - Ion-ion coupling

KW - Laser cooling

KW - Penning-trap mass spectrometry

UR - http://www.scopus.com/inward/record.url?scp=84998673674&partnerID=8YFLogxK

U2 - 10.1016/j.ijms.2016.10.010

DO - 10.1016/j.ijms.2016.10.010

M3 - Article

AN - SCOPUS:84998673674

VL - 410

SP - 22

EP - 30

JO - International Journal of Mass Spectrometry

JF - International Journal of Mass Spectrometry

SN - 1387-3806

ER -

Von denselben Autoren