An experimental demonstration of resonant sideband extraction for laser-interferometric gravitational wave detectors

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

  • G. Heinzel
  • J. Mizuno
  • R. Schilling
  • W. Winkler
  • A. Rüdiger
  • K. Danzmann

Externe Organisationen

  • Max-Planck-Institut für Quantenoptik (MPQ)
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)305-314
Seitenumfang10
FachzeitschriftPhysics Letters, Section A: General, Atomic and Solid State Physics
Jahrgang217
Ausgabenummer6
PublikationsstatusVeröffentlicht - 22 Juli 1996

Abstract

Resonant sideband extraction is a new optical configuration for laser-interferometric gravitational wave detectors with Fabry-Perot cavities in the arms. It reduces the thermal load on the beam splitter and the coupling mirrors of the cavities and also allows one to adapt the frequency response of the detector to a variety of requirements. We report the first experimental demonstration using a table-top setup at a detuned operating point. An increase of sensitivity by 6 dB was observed for artificial signals at frequencies above the arm cavity bandwidth, and the overall transfer function agreed well with theoretical predictions.

ASJC Scopus Sachgebiete

Zitieren

An experimental demonstration of resonant sideband extraction for laser-interferometric gravitational wave detectors. / Heinzel, G.; Mizuno, J.; Schilling, R. et al.
in: Physics Letters, Section A: General, Atomic and Solid State Physics, Jahrgang 217, Nr. 6, 22.07.1996, S. 305-314.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Heinzel G, Mizuno J, Schilling R, Winkler W, Rüdiger A, Danzmann K. An experimental demonstration of resonant sideband extraction for laser-interferometric gravitational wave detectors. Physics Letters, Section A: General, Atomic and Solid State Physics. 1996 Jul 22;217(6):305-314. doi: 10.1016/0375-9601(96)00361-1
Download
@article{ebdb04a24686454886a6e4b339edcdb1,
title = "An experimental demonstration of resonant sideband extraction for laser-interferometric gravitational wave detectors",
abstract = "Resonant sideband extraction is a new optical configuration for laser-interferometric gravitational wave detectors with Fabry-Perot cavities in the arms. It reduces the thermal load on the beam splitter and the coupling mirrors of the cavities and also allows one to adapt the frequency response of the detector to a variety of requirements. We report the first experimental demonstration using a table-top setup at a detuned operating point. An increase of sensitivity by 6 dB was observed for artificial signals at frequencies above the arm cavity bandwidth, and the overall transfer function agreed well with theoretical predictions.",
keywords = "Fabry-Perot, Gravitational wave detector, Mach-Zehnder, Michelson interferometer, Resonant sideband extraction, Three-mirror cavity",
author = "G. Heinzel and J. Mizuno and R. Schilling and W. Winkler and A. R{\"u}diger and K. Danzmann",
year = "1996",
month = jul,
day = "22",
doi = "10.1016/0375-9601(96)00361-1",
language = "English",
volume = "217",
pages = "305--314",
journal = "Physics Letters, Section A: General, Atomic and Solid State Physics",
issn = "0375-9601",
publisher = "Elsevier",
number = "6",

}

Download

TY - JOUR

T1 - An experimental demonstration of resonant sideband extraction for laser-interferometric gravitational wave detectors

AU - Heinzel, G.

AU - Mizuno, J.

AU - Schilling, R.

AU - Winkler, W.

AU - Rüdiger, A.

AU - Danzmann, K.

PY - 1996/7/22

Y1 - 1996/7/22

N2 - Resonant sideband extraction is a new optical configuration for laser-interferometric gravitational wave detectors with Fabry-Perot cavities in the arms. It reduces the thermal load on the beam splitter and the coupling mirrors of the cavities and also allows one to adapt the frequency response of the detector to a variety of requirements. We report the first experimental demonstration using a table-top setup at a detuned operating point. An increase of sensitivity by 6 dB was observed for artificial signals at frequencies above the arm cavity bandwidth, and the overall transfer function agreed well with theoretical predictions.

AB - Resonant sideband extraction is a new optical configuration for laser-interferometric gravitational wave detectors with Fabry-Perot cavities in the arms. It reduces the thermal load on the beam splitter and the coupling mirrors of the cavities and also allows one to adapt the frequency response of the detector to a variety of requirements. We report the first experimental demonstration using a table-top setup at a detuned operating point. An increase of sensitivity by 6 dB was observed for artificial signals at frequencies above the arm cavity bandwidth, and the overall transfer function agreed well with theoretical predictions.

KW - Fabry-Perot

KW - Gravitational wave detector

KW - Mach-Zehnder

KW - Michelson interferometer

KW - Resonant sideband extraction

KW - Three-mirror cavity

UR - http://www.scopus.com/inward/record.url?scp=0001571335&partnerID=8YFLogxK

U2 - 10.1016/0375-9601(96)00361-1

DO - 10.1016/0375-9601(96)00361-1

M3 - Article

AN - SCOPUS:0001571335

VL - 217

SP - 305

EP - 314

JO - Physics Letters, Section A: General, Atomic and Solid State Physics

JF - Physics Letters, Section A: General, Atomic and Solid State Physics

SN - 0375-9601

IS - 6

ER -