Air-Coupled Ultrasound Time Reversal (ACU-TR) for Subwavelength Nondestructive Imaging

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

  • Torben Marhenke
  • Jürg Neuenschwander
  • Roman Furrer
  • Peter Zolliker
  • Jens Twiefel
  • Jörg Hasener
  • Jörg Wallaschek
  • Sergio J. Sanabria

Externe Organisationen

  • Fagus-GreCon Greten GmbH & Co. KG
  • Eidgenössische Materialprüfungs- und Forschungsanstalt (EMPA)
  • Universität Zürich (UZH)
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)651-663
Seitenumfang13
FachzeitschriftIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Jahrgang67
Ausgabenummer3
PublikationsstatusVeröffentlicht - 2019

Abstract

Air-coupled ultrasound (ACU) is increasingly used for nondestructive testing (NDT). With ACU, no contact or coupling agent (e.g., water and ultrasound gel) is needed between transducers and test sample, which provides high measurement reproducibility. However, for testing in production, a minimum separation is often necessary between the sample and the transducers to avoid contamination or transducer damage. Due to wave diffraction, the collimation of the ultrasound beam decreases for larger propagation distances, and ACU images become blurred and show lower defect lateral resolution with increasing sample-transducer separation. This is especially critical to thick composites, where large-size planar sources are used to bridge the large ACU transmission loss with good collimation. In this work, ACU reradiation in unbounded media is extended to NDT of multilayered composites. The extended method is named ACU time reversal (ACU-TR) and significantly improves the defect resolution of ACU imaging. With ACU-TR, the complete pressure distribution radiated by large ACU source is measured with point receivers (RXs) in one plane arbitrarily separated from the sample. By applying acoustic holography physics, it is then possible to quantitatively reconstruct the pressure field directly at arbitrary sample defect planes, which compensates for undesired diffraction phenomena and improves minimum detectable defect size, thereby achieving subwavelength lateral resolution. We tested the method on complex wood-based composite samples based on the ACU far-field measurements at a separation of 160 mm between the sample and the RX transducer. With the proposed method, it is possible to detect surface defects as well as inner defects within composite boards. In the future, by using point RX arrays instead of a scanned microphone, both data acquisition and evaluation can be potentially implemented in real time.

ASJC Scopus Sachgebiete

Zitieren

Air-Coupled Ultrasound Time Reversal (ACU-TR) for Subwavelength Nondestructive Imaging. / Marhenke, Torben; Neuenschwander, Jürg; Furrer, Roman et al.
in: IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, Jahrgang 67, Nr. 3, 2019, S. 651-663.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Marhenke, T, Neuenschwander, J, Furrer, R, Zolliker, P, Twiefel, J, Hasener, J, Wallaschek, J & Sanabria, SJ 2019, 'Air-Coupled Ultrasound Time Reversal (ACU-TR) for Subwavelength Nondestructive Imaging', IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, Jg. 67, Nr. 3, S. 651-663. https://doi.org/10.1109/TUFFC.2019.2951312
Marhenke, T., Neuenschwander, J., Furrer, R., Zolliker, P., Twiefel, J., Hasener, J., Wallaschek, J., & Sanabria, S. J. (2019). Air-Coupled Ultrasound Time Reversal (ACU-TR) for Subwavelength Nondestructive Imaging. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 67(3), 651-663. https://doi.org/10.1109/TUFFC.2019.2951312
Marhenke T, Neuenschwander J, Furrer R, Zolliker P, Twiefel J, Hasener J et al. Air-Coupled Ultrasound Time Reversal (ACU-TR) for Subwavelength Nondestructive Imaging. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 2019;67(3):651-663. doi: 10.1109/TUFFC.2019.2951312
Marhenke, Torben ; Neuenschwander, Jürg ; Furrer, Roman et al. / Air-Coupled Ultrasound Time Reversal (ACU-TR) for Subwavelength Nondestructive Imaging. in: IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 2019 ; Jahrgang 67, Nr. 3. S. 651-663.
Download
@article{55a82dac86214bc19403ce2bfb83e51f,
title = "Air-Coupled Ultrasound Time Reversal (ACU-TR) for Subwavelength Nondestructive Imaging",
abstract = "Air-coupled ultrasound (ACU) is increasingly used for nondestructive testing (NDT). With ACU, no contact or coupling agent (e.g., water and ultrasound gel) is needed between transducers and test sample, which provides high measurement reproducibility. However, for testing in production, a minimum separation is often necessary between the sample and the transducers to avoid contamination or transducer damage. Due to wave diffraction, the collimation of the ultrasound beam decreases for larger propagation distances, and ACU images become blurred and show lower defect lateral resolution with increasing sample-transducer separation. This is especially critical to thick composites, where large-size planar sources are used to bridge the large ACU transmission loss with good collimation. In this work, ACU reradiation in unbounded media is extended to NDT of multilayered composites. The extended method is named ACU time reversal (ACU-TR) and significantly improves the defect resolution of ACU imaging. With ACU-TR, the complete pressure distribution radiated by large ACU source is measured with point receivers (RXs) in one plane arbitrarily separated from the sample. By applying acoustic holography physics, it is then possible to quantitatively reconstruct the pressure field directly at arbitrary sample defect planes, which compensates for undesired diffraction phenomena and improves minimum detectable defect size, thereby achieving subwavelength lateral resolution. We tested the method on complex wood-based composite samples based on the ACU far-field measurements at a separation of 160 mm between the sample and the RX transducer. With the proposed method, it is possible to detect surface defects as well as inner defects within composite boards. In the future, by using point RX arrays instead of a scanned microphone, both data acquisition and evaluation can be potentially implemented in real time.",
keywords = "Air-coupled ultrasound (ACU) nondestructive testing (NDT), gluing defects, inverse problem, time reversal, wood-based composite materials",
author = "Torben Marhenke and J{\"u}rg Neuenschwander and Roman Furrer and Peter Zolliker and Jens Twiefel and J{\"o}rg Hasener and J{\"o}rg Wallaschek and Sanabria, {Sergio J.}",
note = "Acknowledgement: The experiments were performed at the Swiss Federal Laboratories for Materials Science and Technology (Empa, D{\"u}bendorf). Empa contributed to this study with their equipment",
year = "2019",
doi = "10.1109/TUFFC.2019.2951312",
language = "English",
volume = "67",
pages = "651--663",
journal = "IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control",
issn = "0885-3010",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "3",

}

Download

TY - JOUR

T1 - Air-Coupled Ultrasound Time Reversal (ACU-TR) for Subwavelength Nondestructive Imaging

AU - Marhenke, Torben

AU - Neuenschwander, Jürg

AU - Furrer, Roman

AU - Zolliker, Peter

AU - Twiefel, Jens

AU - Hasener, Jörg

AU - Wallaschek, Jörg

AU - Sanabria, Sergio J.

N1 - Acknowledgement: The experiments were performed at the Swiss Federal Laboratories for Materials Science and Technology (Empa, Dübendorf). Empa contributed to this study with their equipment

PY - 2019

Y1 - 2019

N2 - Air-coupled ultrasound (ACU) is increasingly used for nondestructive testing (NDT). With ACU, no contact or coupling agent (e.g., water and ultrasound gel) is needed between transducers and test sample, which provides high measurement reproducibility. However, for testing in production, a minimum separation is often necessary between the sample and the transducers to avoid contamination or transducer damage. Due to wave diffraction, the collimation of the ultrasound beam decreases for larger propagation distances, and ACU images become blurred and show lower defect lateral resolution with increasing sample-transducer separation. This is especially critical to thick composites, where large-size planar sources are used to bridge the large ACU transmission loss with good collimation. In this work, ACU reradiation in unbounded media is extended to NDT of multilayered composites. The extended method is named ACU time reversal (ACU-TR) and significantly improves the defect resolution of ACU imaging. With ACU-TR, the complete pressure distribution radiated by large ACU source is measured with point receivers (RXs) in one plane arbitrarily separated from the sample. By applying acoustic holography physics, it is then possible to quantitatively reconstruct the pressure field directly at arbitrary sample defect planes, which compensates for undesired diffraction phenomena and improves minimum detectable defect size, thereby achieving subwavelength lateral resolution. We tested the method on complex wood-based composite samples based on the ACU far-field measurements at a separation of 160 mm between the sample and the RX transducer. With the proposed method, it is possible to detect surface defects as well as inner defects within composite boards. In the future, by using point RX arrays instead of a scanned microphone, both data acquisition and evaluation can be potentially implemented in real time.

AB - Air-coupled ultrasound (ACU) is increasingly used for nondestructive testing (NDT). With ACU, no contact or coupling agent (e.g., water and ultrasound gel) is needed between transducers and test sample, which provides high measurement reproducibility. However, for testing in production, a minimum separation is often necessary between the sample and the transducers to avoid contamination or transducer damage. Due to wave diffraction, the collimation of the ultrasound beam decreases for larger propagation distances, and ACU images become blurred and show lower defect lateral resolution with increasing sample-transducer separation. This is especially critical to thick composites, where large-size planar sources are used to bridge the large ACU transmission loss with good collimation. In this work, ACU reradiation in unbounded media is extended to NDT of multilayered composites. The extended method is named ACU time reversal (ACU-TR) and significantly improves the defect resolution of ACU imaging. With ACU-TR, the complete pressure distribution radiated by large ACU source is measured with point receivers (RXs) in one plane arbitrarily separated from the sample. By applying acoustic holography physics, it is then possible to quantitatively reconstruct the pressure field directly at arbitrary sample defect planes, which compensates for undesired diffraction phenomena and improves minimum detectable defect size, thereby achieving subwavelength lateral resolution. We tested the method on complex wood-based composite samples based on the ACU far-field measurements at a separation of 160 mm between the sample and the RX transducer. With the proposed method, it is possible to detect surface defects as well as inner defects within composite boards. In the future, by using point RX arrays instead of a scanned microphone, both data acquisition and evaluation can be potentially implemented in real time.

KW - Air-coupled ultrasound (ACU) nondestructive testing (NDT)

KW - gluing defects

KW - inverse problem

KW - time reversal

KW - wood-based composite materials

UR - http://www.scopus.com/inward/record.url?scp=85080909373&partnerID=8YFLogxK

U2 - 10.1109/TUFFC.2019.2951312

DO - 10.1109/TUFFC.2019.2951312

M3 - Article

C2 - 31689191

AN - SCOPUS:85080909373

VL - 67

SP - 651

EP - 663

JO - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control

JF - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control

SN - 0885-3010

IS - 3

ER -