Advantages of compound-specific stable isotope measurements over bulk measurements in studies on plant uptake of intact amino acids

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autorschaft

Externe Organisationen

  • Universität Bayreuth
  • Friedrich-Schiller-Universität Jena
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)3333-3342
Seitenumfang10
FachzeitschriftRapid Communications in Mass Spectrometry
Jahrgang23
Ausgabenummer20
PublikationsstatusVeröffentlicht - 30 Okt. 2009

Abstract

Increasing interest in the ability of plants to take up amino acids has given rise to questions on the accuracy of the commonly used bulk method to measure and calculate amino acid uptake. This method uses bulk measurements of 13C and 15N enrichment in plant tissues after application of duallabelled amino acids but some authors have recommended the use of compound-specific stable isotope (CSI) analysis of the plants' amino acids instead. However, there has never been a direct evaluation of both methods. We conducted a field study applying dual-labelled (13C, 15N) amino acids (glycine, valine, tyrosine and lysine) to soil of a Plantago lanceolata monoculture. Root and shoot samples were collected 24 h after label application and the isotope composition of the plant tissues was investigated using bulk and CSI measurements. Enrichment of 13C in the case of CSI measurements was limited to the applied amino acids. showing that no additional 13C had been incorporated into the plants' amino acid pool via the uptake of tracer-derived C-fragments. Compared with this rather conservative indicator of amino acid uptake, the 13C enrichment of bulk measurements was 8, 5,1.6 and 6 times higher for fine roots, storage roots, shoot and the whole plant, respectively. These findings show that the additional uptake of tracer-derived C-fragments will result in a considerable overestimation of amino acid uptake in the case of bulk measurements. We therefore highly recommend the use of CSI measurements for future amino acid uptake studies due to their higher accuracy.

ASJC Scopus Sachgebiete

Zitieren

Advantages of compound-specific stable isotope measurements over bulk measurements in studies on plant uptake of intact amino acids. / Sauheitl, Leopold; Glaser, Bruno; Weigelt, Alexandra.
in: Rapid Communications in Mass Spectrometry, Jahrgang 23, Nr. 20, 30.10.2009, S. 3333-3342.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Download
@article{d0e057c320304c8bb360dcde6dbd303a,
title = "Advantages of compound-specific stable isotope measurements over bulk measurements in studies on plant uptake of intact amino acids",
abstract = "Increasing interest in the ability of plants to take up amino acids has given rise to questions on the accuracy of the commonly used bulk method to measure and calculate amino acid uptake. This method uses bulk measurements of 13C and 15N enrichment in plant tissues after application of duallabelled amino acids but some authors have recommended the use of compound-specific stable isotope (CSI) analysis of the plants' amino acids instead. However, there has never been a direct evaluation of both methods. We conducted a field study applying dual-labelled (13C, 15N) amino acids (glycine, valine, tyrosine and lysine) to soil of a Plantago lanceolata monoculture. Root and shoot samples were collected 24 h after label application and the isotope composition of the plant tissues was investigated using bulk and CSI measurements. Enrichment of 13C in the case of CSI measurements was limited to the applied amino acids. showing that no additional 13C had been incorporated into the plants' amino acid pool via the uptake of tracer-derived C-fragments. Compared with this rather conservative indicator of amino acid uptake, the 13C enrichment of bulk measurements was 8, 5,1.6 and 6 times higher for fine roots, storage roots, shoot and the whole plant, respectively. These findings show that the additional uptake of tracer-derived C-fragments will result in a considerable overestimation of amino acid uptake in the case of bulk measurements. We therefore highly recommend the use of CSI measurements for future amino acid uptake studies due to their higher accuracy.",
author = "Leopold Sauheitl and Bruno Glaser and Alexandra Weigelt",
note = "Copyright: Copyright 2011 Elsevier B.V., All rights reserved.",
year = "2009",
month = oct,
day = "30",
doi = "10.1002/rcm.4255",
language = "English",
volume = "23",
pages = "3333--3342",
journal = "Rapid Communications in Mass Spectrometry",
issn = "0951-4198",
publisher = "John Wiley and Sons Ltd",
number = "20",

}

Download

TY - JOUR

T1 - Advantages of compound-specific stable isotope measurements over bulk measurements in studies on plant uptake of intact amino acids

AU - Sauheitl, Leopold

AU - Glaser, Bruno

AU - Weigelt, Alexandra

N1 - Copyright: Copyright 2011 Elsevier B.V., All rights reserved.

PY - 2009/10/30

Y1 - 2009/10/30

N2 - Increasing interest in the ability of plants to take up amino acids has given rise to questions on the accuracy of the commonly used bulk method to measure and calculate amino acid uptake. This method uses bulk measurements of 13C and 15N enrichment in plant tissues after application of duallabelled amino acids but some authors have recommended the use of compound-specific stable isotope (CSI) analysis of the plants' amino acids instead. However, there has never been a direct evaluation of both methods. We conducted a field study applying dual-labelled (13C, 15N) amino acids (glycine, valine, tyrosine and lysine) to soil of a Plantago lanceolata monoculture. Root and shoot samples were collected 24 h after label application and the isotope composition of the plant tissues was investigated using bulk and CSI measurements. Enrichment of 13C in the case of CSI measurements was limited to the applied amino acids. showing that no additional 13C had been incorporated into the plants' amino acid pool via the uptake of tracer-derived C-fragments. Compared with this rather conservative indicator of amino acid uptake, the 13C enrichment of bulk measurements was 8, 5,1.6 and 6 times higher for fine roots, storage roots, shoot and the whole plant, respectively. These findings show that the additional uptake of tracer-derived C-fragments will result in a considerable overestimation of amino acid uptake in the case of bulk measurements. We therefore highly recommend the use of CSI measurements for future amino acid uptake studies due to their higher accuracy.

AB - Increasing interest in the ability of plants to take up amino acids has given rise to questions on the accuracy of the commonly used bulk method to measure and calculate amino acid uptake. This method uses bulk measurements of 13C and 15N enrichment in plant tissues after application of duallabelled amino acids but some authors have recommended the use of compound-specific stable isotope (CSI) analysis of the plants' amino acids instead. However, there has never been a direct evaluation of both methods. We conducted a field study applying dual-labelled (13C, 15N) amino acids (glycine, valine, tyrosine and lysine) to soil of a Plantago lanceolata monoculture. Root and shoot samples were collected 24 h after label application and the isotope composition of the plant tissues was investigated using bulk and CSI measurements. Enrichment of 13C in the case of CSI measurements was limited to the applied amino acids. showing that no additional 13C had been incorporated into the plants' amino acid pool via the uptake of tracer-derived C-fragments. Compared with this rather conservative indicator of amino acid uptake, the 13C enrichment of bulk measurements was 8, 5,1.6 and 6 times higher for fine roots, storage roots, shoot and the whole plant, respectively. These findings show that the additional uptake of tracer-derived C-fragments will result in a considerable overestimation of amino acid uptake in the case of bulk measurements. We therefore highly recommend the use of CSI measurements for future amino acid uptake studies due to their higher accuracy.

UR - http://www.scopus.com/inward/record.url?scp=70449413753&partnerID=8YFLogxK

U2 - 10.1002/rcm.4255

DO - 10.1002/rcm.4255

M3 - Article

C2 - 19757447

AN - SCOPUS:70449413753

VL - 23

SP - 3333

EP - 3342

JO - Rapid Communications in Mass Spectrometry

JF - Rapid Communications in Mass Spectrometry

SN - 0951-4198

IS - 20

ER -

Von denselben Autoren