Partial discharge (PD) detection in the ultra-high frequency (UHF) range is state of the art. One of the most critical points in this detection method is adopting proper and suitable antenna design. In this paper, a new design of UHF antennas is introduced which is suitable to be used on the transformers in the HV laboratories of the manufacturers. To ensure the applicability of the new antenna, experimental UHF PD measurements are carried out on a transformer tank model as well as on the real power transformers. Installing several UHF antennas on the transformer tank to perform defect localization is also an important issue. There are rigorous limitations and lack of the places to install the antennas. This problem is almost solved by using the mentioned new antenna design. The proper positioning of the antennas is the other critical point in the UHF method. Placing the antennas in improper positions will damage the localization accuracy. In this paper, an automatic algorithm is introduced to determine the best installation positions for the antennas to enhance the localization accuracy. The efficacy of this algorithm is investigated by using the results of experimental measurements on power transformers.

ASJC Scopus Sachgebiete

Zitieren

Advancing new techniques for UHF PDdetection and localization in the power transformers in the factory tests. / Mirzaei, H.; Akbari, A.; Gockenbach, E. et al.
in: IEEE Transactions on Dielectrics and Electrical Insulation, Jahrgang 22, Nr. 1, 7033415, 01.02.2015, S. 448-455.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Mirzaei H, Akbari A, Gockenbach E, Miralikhani K. Advancing new techniques for UHF PDdetection and localization in the power transformers in the factory tests. IEEE Transactions on Dielectrics and Electrical Insulation. 2015 Feb 1;22(1):448-455. 7033415. doi: 10.1109/TDEI.2014.004249
Download
@article{d851fc444391430b8a220327fdc633c9,
title = "Advancing new techniques for UHF PDdetection and localization in the power transformers in the factory tests",
abstract = "Partial discharge (PD) detection in the ultra-high frequency (UHF) range is state of the art. One of the most critical points in this detection method is adopting proper and suitable antenna design. In this paper, a new design of UHF antennas is introduced which is suitable to be used on the transformers in the HV laboratories of the manufacturers. To ensure the applicability of the new antenna, experimental UHF PD measurements are carried out on a transformer tank model as well as on the real power transformers. Installing several UHF antennas on the transformer tank to perform defect localization is also an important issue. There are rigorous limitations and lack of the places to install the antennas. This problem is almost solved by using the mentioned new antenna design. The proper positioning of the antennas is the other critical point in the UHF method. Placing the antennas in improper positions will damage the localization accuracy. In this paper, an automatic algorithm is introduced to determine the best installation positions for the antennas to enhance the localization accuracy. The efficacy of this algorithm is investigated by using the results of experimental measurements on power transformers.",
keywords = "Partial discharge, power transformer, UHF antenna, ultra-high frequency",
author = "H. Mirzaei and A. Akbari and E. Gockenbach and Karim Miralikhani",
year = "2015",
month = feb,
day = "1",
doi = "10.1109/TDEI.2014.004249",
language = "English",
volume = "22",
pages = "448--455",
journal = "IEEE Transactions on Dielectrics and Electrical Insulation",
issn = "1070-9878",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "1",

}

Download

TY - JOUR

T1 - Advancing new techniques for UHF PDdetection and localization in the power transformers in the factory tests

AU - Mirzaei, H.

AU - Akbari, A.

AU - Gockenbach, E.

AU - Miralikhani , Karim

PY - 2015/2/1

Y1 - 2015/2/1

N2 - Partial discharge (PD) detection in the ultra-high frequency (UHF) range is state of the art. One of the most critical points in this detection method is adopting proper and suitable antenna design. In this paper, a new design of UHF antennas is introduced which is suitable to be used on the transformers in the HV laboratories of the manufacturers. To ensure the applicability of the new antenna, experimental UHF PD measurements are carried out on a transformer tank model as well as on the real power transformers. Installing several UHF antennas on the transformer tank to perform defect localization is also an important issue. There are rigorous limitations and lack of the places to install the antennas. This problem is almost solved by using the mentioned new antenna design. The proper positioning of the antennas is the other critical point in the UHF method. Placing the antennas in improper positions will damage the localization accuracy. In this paper, an automatic algorithm is introduced to determine the best installation positions for the antennas to enhance the localization accuracy. The efficacy of this algorithm is investigated by using the results of experimental measurements on power transformers.

AB - Partial discharge (PD) detection in the ultra-high frequency (UHF) range is state of the art. One of the most critical points in this detection method is adopting proper and suitable antenna design. In this paper, a new design of UHF antennas is introduced which is suitable to be used on the transformers in the HV laboratories of the manufacturers. To ensure the applicability of the new antenna, experimental UHF PD measurements are carried out on a transformer tank model as well as on the real power transformers. Installing several UHF antennas on the transformer tank to perform defect localization is also an important issue. There are rigorous limitations and lack of the places to install the antennas. This problem is almost solved by using the mentioned new antenna design. The proper positioning of the antennas is the other critical point in the UHF method. Placing the antennas in improper positions will damage the localization accuracy. In this paper, an automatic algorithm is introduced to determine the best installation positions for the antennas to enhance the localization accuracy. The efficacy of this algorithm is investigated by using the results of experimental measurements on power transformers.

KW - Partial discharge

KW - power transformer

KW - UHF antenna

KW - ultra-high frequency

UR - http://www.scopus.com/inward/record.url?scp=84923082633&partnerID=8YFLogxK

U2 - 10.1109/TDEI.2014.004249

DO - 10.1109/TDEI.2014.004249

M3 - Article

AN - SCOPUS:84923082633

VL - 22

SP - 448

EP - 455

JO - IEEE Transactions on Dielectrics and Electrical Insulation

JF - IEEE Transactions on Dielectrics and Electrical Insulation

SN - 1070-9878

IS - 1

M1 - 7033415

ER -