Accurate Segmentation of Single Isolated Human Insulin Crystals for In-Situ Microscopy

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Autoren

Organisationseinheiten

Externe Organisationen

  • Universidad de Costa Rica
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Titel des Sammelwerks2014 International Conference on Electronics, Communications and Computers (CONIELECOMP)
Seiten105-110
Seitenumfang6
ISBN (elektronisch)978-1-4799-3469-0, 978-1-4799-3468-3
PublikationsstatusVeröffentlicht - 1 Mai 2014
Veranstaltung24th International Conference on Electronics, Communications and Computers, CONIELECOMP 2014 - Cholula, Mexiko
Dauer: 26 Feb. 201428 Feb. 2014

Abstract

An Algorithm is presented for accurate segmentation of single isolated human insulin crystals in an image captured by an in situ microscope inside of a bioreactor. It consists of three major steps. First, the foreground regions are extracted by thresholding the image. Then, the regions which correspond to the single isolated human insulin crystals are detected among the previously segmented foreground regions using a single nearest prototype rule, where each segmented foreground region class prototype represents a 7-dimensional mean vector of rotation, translation and scale invariant shape characteristics of several class members, which were extracted a priori from a training set of images. Finally, the contour accuracy of the detected regions is improved by moving each contour point to that image position where the weighted sum of the image intensity and the first and the second contour derivatives is minimal. The search of the minimum is carried out only along the line segment that goes from the region contour point position to the position of the region center of gravity. Experiments with 60 real images revealed very accurate segmentation results with an average contour accuracy of 1.61±2.53 pixel.

ASJC Scopus Sachgebiete

Zitieren

Accurate Segmentation of Single Isolated Human Insulin Crystals for In-Situ Microscopy. / Martinez, G.; Lindner, P.; Bluma, A. et al.
2014 International Conference on Electronics, Communications and Computers (CONIELECOMP). 2014. S. 105-110.

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Martinez, G, Lindner, P, Bluma, A & Scheper, T 2014, Accurate Segmentation of Single Isolated Human Insulin Crystals for In-Situ Microscopy. in 2014 International Conference on Electronics, Communications and Computers (CONIELECOMP). S. 105-110, 24th International Conference on Electronics, Communications and Computers, CONIELECOMP 2014, Cholula, Mexiko, 26 Feb. 2014. https://doi.org/10.1109/conielecomp.2014.6808576
Martinez, G., Lindner, P., Bluma, A., & Scheper, T. (2014). Accurate Segmentation of Single Isolated Human Insulin Crystals for In-Situ Microscopy. In 2014 International Conference on Electronics, Communications and Computers (CONIELECOMP) (S. 105-110) https://doi.org/10.1109/conielecomp.2014.6808576
Martinez G, Lindner P, Bluma A, Scheper T. Accurate Segmentation of Single Isolated Human Insulin Crystals for In-Situ Microscopy. in 2014 International Conference on Electronics, Communications and Computers (CONIELECOMP). 2014. S. 105-110 doi: 10.1109/conielecomp.2014.6808576
Martinez, G. ; Lindner, P. ; Bluma, A. et al. / Accurate Segmentation of Single Isolated Human Insulin Crystals for In-Situ Microscopy. 2014 International Conference on Electronics, Communications and Computers (CONIELECOMP). 2014. S. 105-110
Download
@inproceedings{c01e2af1674843159bbf05aabb762b3c,
title = "Accurate Segmentation of Single Isolated Human Insulin Crystals for In-Situ Microscopy",
abstract = "An Algorithm is presented for accurate segmentation of single isolated human insulin crystals in an image captured by an in situ microscope inside of a bioreactor. It consists of three major steps. First, the foreground regions are extracted by thresholding the image. Then, the regions which correspond to the single isolated human insulin crystals are detected among the previously segmented foreground regions using a single nearest prototype rule, where each segmented foreground region class prototype represents a 7-dimensional mean vector of rotation, translation and scale invariant shape characteristics of several class members, which were extracted a priori from a training set of images. Finally, the contour accuracy of the detected regions is improved by moving each contour point to that image position where the weighted sum of the image intensity and the first and the second contour derivatives is minimal. The search of the minimum is carried out only along the line segment that goes from the region contour point position to the position of the region center of gravity. Experiments with 60 real images revealed very accurate segmentation results with an average contour accuracy of 1.61±2.53 pixel.",
author = "G. Martinez and P. Lindner and A. Bluma and T. Scheper",
year = "2014",
month = may,
day = "1",
doi = "10.1109/conielecomp.2014.6808576",
language = "English",
pages = "105--110",
booktitle = "2014 International Conference on Electronics, Communications and Computers (CONIELECOMP)",
note = "24th International Conference on Electronics, Communications and Computers, CONIELECOMP 2014 ; Conference date: 26-02-2014 Through 28-02-2014",

}

Download

TY - GEN

T1 - Accurate Segmentation of Single Isolated Human Insulin Crystals for In-Situ Microscopy

AU - Martinez, G.

AU - Lindner, P.

AU - Bluma, A.

AU - Scheper, T.

PY - 2014/5/1

Y1 - 2014/5/1

N2 - An Algorithm is presented for accurate segmentation of single isolated human insulin crystals in an image captured by an in situ microscope inside of a bioreactor. It consists of three major steps. First, the foreground regions are extracted by thresholding the image. Then, the regions which correspond to the single isolated human insulin crystals are detected among the previously segmented foreground regions using a single nearest prototype rule, where each segmented foreground region class prototype represents a 7-dimensional mean vector of rotation, translation and scale invariant shape characteristics of several class members, which were extracted a priori from a training set of images. Finally, the contour accuracy of the detected regions is improved by moving each contour point to that image position where the weighted sum of the image intensity and the first and the second contour derivatives is minimal. The search of the minimum is carried out only along the line segment that goes from the region contour point position to the position of the region center of gravity. Experiments with 60 real images revealed very accurate segmentation results with an average contour accuracy of 1.61±2.53 pixel.

AB - An Algorithm is presented for accurate segmentation of single isolated human insulin crystals in an image captured by an in situ microscope inside of a bioreactor. It consists of three major steps. First, the foreground regions are extracted by thresholding the image. Then, the regions which correspond to the single isolated human insulin crystals are detected among the previously segmented foreground regions using a single nearest prototype rule, where each segmented foreground region class prototype represents a 7-dimensional mean vector of rotation, translation and scale invariant shape characteristics of several class members, which were extracted a priori from a training set of images. Finally, the contour accuracy of the detected regions is improved by moving each contour point to that image position where the weighted sum of the image intensity and the first and the second contour derivatives is minimal. The search of the minimum is carried out only along the line segment that goes from the region contour point position to the position of the region center of gravity. Experiments with 60 real images revealed very accurate segmentation results with an average contour accuracy of 1.61±2.53 pixel.

UR - http://www.scopus.com/inward/record.url?scp=84901260712&partnerID=8YFLogxK

U2 - 10.1109/conielecomp.2014.6808576

DO - 10.1109/conielecomp.2014.6808576

M3 - Conference contribution

AN - SCOPUS:84901260712

SP - 105

EP - 110

BT - 2014 International Conference on Electronics, Communications and Computers (CONIELECOMP)

T2 - 24th International Conference on Electronics, Communications and Computers, CONIELECOMP 2014

Y2 - 26 February 2014 through 28 February 2014

ER -

Von denselben Autoren