Accuracy of optical navigation systems for automatic head surgery: optical tracking versus optical coherence tomography

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Autorschaft

  • Jesús Díaz Díaz
  • Mauro H. Riva
  • Omid Majdani
  • Tobias Ortmaier

Organisationseinheiten

Externe Organisationen

  • Medizinische Hochschule Hannover (MHH)
  • Exzellenzcluster Hearing4all
  • Vanderbilt University
  • Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU Erlangen-Nürnberg)
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Titel des SammelwerksProceedings of the Society of Photo-Optical Instrumentation Engineers Photonics West 2014 (SPIE Photonics West 2014)
Herausgeber (Verlag)SPIE
ISBN (Print)9780819498397
PublikationsstatusVeröffentlicht - 2014
VeranstaltungPhotonic Therapeutics and Diagnostics X - San Francisco, CA, USA / Vereinigte Staaten
Dauer: 1 Feb. 20142 Feb. 2014

Publikationsreihe

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Band8926
ISSN (Print)1605-7422

Abstract

The choice of a navigation system highly depends on the medical intervention and its accuracy demands. The most commonly used systems for image guided surgery (IGS) are based on optical and magnetic tracking systems. This paper compares two optical systems in terms of accuracy: state of the art triangulation-based optical tracking (OT) and optical coherence tomography (OCT). We use an experimental setup with a combined OCT and cutting laser, and an external OT. We simulate a robotic assisted surgical intervention, including planning, navigation, and processing, and compare the accuracies reached at a specific target with each navigation system.

ASJC Scopus Sachgebiete

Zitieren

Accuracy of optical navigation systems for automatic head surgery: optical tracking versus optical coherence tomography. / Díaz Díaz, Jesús; Riva, Mauro H.; Majdani, Omid et al.
Proceedings of the Society of Photo-Optical Instrumentation Engineers Photonics West 2014 (SPIE Photonics West 2014). SPIE, 2014. 89262F (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; Band 8926).

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Díaz Díaz, J, Riva, MH, Majdani, O & Ortmaier, T 2014, Accuracy of optical navigation systems for automatic head surgery: optical tracking versus optical coherence tomography. in Proceedings of the Society of Photo-Optical Instrumentation Engineers Photonics West 2014 (SPIE Photonics West 2014)., 89262F, Progress in Biomedical Optics and Imaging - Proceedings of SPIE, Bd. 8926, SPIE, Photonic Therapeutics and Diagnostics X, San Francisco, CA, USA / Vereinigte Staaten, 1 Feb. 2014. https://doi.org/10.1117/12.2040263
Díaz Díaz, J., Riva, M. H., Majdani, O., & Ortmaier, T. (2014). Accuracy of optical navigation systems for automatic head surgery: optical tracking versus optical coherence tomography. In Proceedings of the Society of Photo-Optical Instrumentation Engineers Photonics West 2014 (SPIE Photonics West 2014) Artikel 89262F (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; Band 8926). SPIE. https://doi.org/10.1117/12.2040263
Díaz Díaz J, Riva MH, Majdani O, Ortmaier T. Accuracy of optical navigation systems for automatic head surgery: optical tracking versus optical coherence tomography. in Proceedings of the Society of Photo-Optical Instrumentation Engineers Photonics West 2014 (SPIE Photonics West 2014). SPIE. 2014. 89262F. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE). doi: 10.1117/12.2040263
Díaz Díaz, Jesús ; Riva, Mauro H. ; Majdani, Omid et al. / Accuracy of optical navigation systems for automatic head surgery: optical tracking versus optical coherence tomography. Proceedings of the Society of Photo-Optical Instrumentation Engineers Photonics West 2014 (SPIE Photonics West 2014). SPIE, 2014. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE).
Download
@inproceedings{4a3e4ee37b9948359c6a584d29c3dc9c,
title = "Accuracy of optical navigation systems for automatic head surgery: optical tracking versus optical coherence tomography",
abstract = "The choice of a navigation system highly depends on the medical intervention and its accuracy demands. The most commonly used systems for image guided surgery (IGS) are based on optical and magnetic tracking systems. This paper compares two optical systems in terms of accuracy: state of the art triangulation-based optical tracking (OT) and optical coherence tomography (OCT). We use an experimental setup with a combined OCT and cutting laser, and an external OT. We simulate a robotic assisted surgical intervention, including planning, navigation, and processing, and compare the accuracies reached at a specific target with each navigation system.",
keywords = "Cochlear implant surgery, Guidance system, Laser ablation, Navigation system, Optical coherence tomography",
author = "{D{\'i}az D{\'i}az}, Jes{\'u}s and Riva, {Mauro H.} and Omid Majdani and Tobias Ortmaier",
year = "2014",
doi = "10.1117/12.2040263",
language = "English",
isbn = "9780819498397",
series = "Progress in Biomedical Optics and Imaging - Proceedings of SPIE",
publisher = "SPIE",
booktitle = "Proceedings of the Society of Photo-Optical Instrumentation Engineers Photonics West 2014 (SPIE Photonics West 2014)",
address = "United States",
note = "Photonic Therapeutics and Diagnostics X ; Conference date: 01-02-2014 Through 02-02-2014",

}

Download

TY - GEN

T1 - Accuracy of optical navigation systems for automatic head surgery: optical tracking versus optical coherence tomography

AU - Díaz Díaz, Jesús

AU - Riva, Mauro H.

AU - Majdani, Omid

AU - Ortmaier, Tobias

PY - 2014

Y1 - 2014

N2 - The choice of a navigation system highly depends on the medical intervention and its accuracy demands. The most commonly used systems for image guided surgery (IGS) are based on optical and magnetic tracking systems. This paper compares two optical systems in terms of accuracy: state of the art triangulation-based optical tracking (OT) and optical coherence tomography (OCT). We use an experimental setup with a combined OCT and cutting laser, and an external OT. We simulate a robotic assisted surgical intervention, including planning, navigation, and processing, and compare the accuracies reached at a specific target with each navigation system.

AB - The choice of a navigation system highly depends on the medical intervention and its accuracy demands. The most commonly used systems for image guided surgery (IGS) are based on optical and magnetic tracking systems. This paper compares two optical systems in terms of accuracy: state of the art triangulation-based optical tracking (OT) and optical coherence tomography (OCT). We use an experimental setup with a combined OCT and cutting laser, and an external OT. We simulate a robotic assisted surgical intervention, including planning, navigation, and processing, and compare the accuracies reached at a specific target with each navigation system.

KW - Cochlear implant surgery

KW - Guidance system

KW - Laser ablation

KW - Navigation system

KW - Optical coherence tomography

UR - http://www.scopus.com/inward/record.url?scp=84897541192&partnerID=8YFLogxK

U2 - 10.1117/12.2040263

DO - 10.1117/12.2040263

M3 - Conference contribution

AN - SCOPUS:84897541192

SN - 9780819498397

T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE

BT - Proceedings of the Society of Photo-Optical Instrumentation Engineers Photonics West 2014 (SPIE Photonics West 2014)

PB - SPIE

T2 - Photonic Therapeutics and Diagnostics X

Y2 - 1 February 2014 through 2 February 2014

ER -