Absolute gravity determination with JILAG-3 - improved data evaluation and instrumental technics

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

  • L. Timmen
  • R. H. Röder
  • M. Schnüll

Organisationseinheiten

Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)71-80
Seitenumfang10
FachzeitschriftBulletin Géodésique
Jahrgang67
Ausgabenummer2
PublikationsstatusVeröffentlicht - Juli 1993

Abstract

In addition to the on-line data evaluation during the measurements with the absolute gravity meter JILAG-3, a subsequently more intensive examination of the measured time/distance data pairs is performed. This allows an additional assessment of the gravity results, the station quality and the measurement conditions. Sinusoidal disturbances in the raw data deteriorate the determination of gravity. Incoming microseisms affect the mean result of the free-fall experiments randomly after a large number of measurements. Instrumental vibrations of the gravity meter during the measurement procedure may influence the gravity result systematically. A station comparison indicates that a 30 Hz frequency is triggered by JILAG-3 itself and influences the measurements depending on the stability of the foundation. Using a mathematical filter it is possible to separate the deteriorations from the gravity acceleration. Up to now an improvement in the absolute accuracy of gravity after filtering could not be proved, but an increase of the precision is indicated.

ASJC Scopus Sachgebiete

Zitieren

Absolute gravity determination with JILAG-3 - improved data evaluation and instrumental technics. / Timmen, L.; Röder, R. H.; Schnüll, M.
in: Bulletin Géodésique, Jahrgang 67, Nr. 2, 07.1993, S. 71-80.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Timmen L, Röder RH, Schnüll M. Absolute gravity determination with JILAG-3 - improved data evaluation and instrumental technics. Bulletin Géodésique. 1993 Jul;67(2):71-80. doi: 10.1007/BF01371370
Timmen, L. ; Röder, R. H. ; Schnüll, M. / Absolute gravity determination with JILAG-3 - improved data evaluation and instrumental technics. in: Bulletin Géodésique. 1993 ; Jahrgang 67, Nr. 2. S. 71-80.
Download
@article{bf096077956e438a8977962114a1043d,
title = "Absolute gravity determination with JILAG-3 - improved data evaluation and instrumental technics",
abstract = "In addition to the on-line data evaluation during the measurements with the absolute gravity meter JILAG-3, a subsequently more intensive examination of the measured time/distance data pairs is performed. This allows an additional assessment of the gravity results, the station quality and the measurement conditions. Sinusoidal disturbances in the raw data deteriorate the determination of gravity. Incoming microseisms affect the mean result of the free-fall experiments randomly after a large number of measurements. Instrumental vibrations of the gravity meter during the measurement procedure may influence the gravity result systematically. A station comparison indicates that a 30 Hz frequency is triggered by JILAG-3 itself and influences the measurements depending on the stability of the foundation. Using a mathematical filter it is possible to separate the deteriorations from the gravity acceleration. Up to now an improvement in the absolute accuracy of gravity after filtering could not be proved, but an increase of the precision is indicated.",
author = "L. Timmen and R{\"o}der, {R. H.} and M. Schn{\"u}ll",
year = "1993",
month = jul,
doi = "10.1007/BF01371370",
language = "English",
volume = "67",
pages = "71--80",
journal = "Bulletin G{\'e}od{\'e}sique",
issn = "0007-4632",
publisher = "Springer Verlag",
number = "2",

}

Download

TY - JOUR

T1 - Absolute gravity determination with JILAG-3 - improved data evaluation and instrumental technics

AU - Timmen, L.

AU - Röder, R. H.

AU - Schnüll, M.

PY - 1993/7

Y1 - 1993/7

N2 - In addition to the on-line data evaluation during the measurements with the absolute gravity meter JILAG-3, a subsequently more intensive examination of the measured time/distance data pairs is performed. This allows an additional assessment of the gravity results, the station quality and the measurement conditions. Sinusoidal disturbances in the raw data deteriorate the determination of gravity. Incoming microseisms affect the mean result of the free-fall experiments randomly after a large number of measurements. Instrumental vibrations of the gravity meter during the measurement procedure may influence the gravity result systematically. A station comparison indicates that a 30 Hz frequency is triggered by JILAG-3 itself and influences the measurements depending on the stability of the foundation. Using a mathematical filter it is possible to separate the deteriorations from the gravity acceleration. Up to now an improvement in the absolute accuracy of gravity after filtering could not be proved, but an increase of the precision is indicated.

AB - In addition to the on-line data evaluation during the measurements with the absolute gravity meter JILAG-3, a subsequently more intensive examination of the measured time/distance data pairs is performed. This allows an additional assessment of the gravity results, the station quality and the measurement conditions. Sinusoidal disturbances in the raw data deteriorate the determination of gravity. Incoming microseisms affect the mean result of the free-fall experiments randomly after a large number of measurements. Instrumental vibrations of the gravity meter during the measurement procedure may influence the gravity result systematically. A station comparison indicates that a 30 Hz frequency is triggered by JILAG-3 itself and influences the measurements depending on the stability of the foundation. Using a mathematical filter it is possible to separate the deteriorations from the gravity acceleration. Up to now an improvement in the absolute accuracy of gravity after filtering could not be proved, but an increase of the precision is indicated.

UR - http://www.scopus.com/inward/record.url?scp=34250079389&partnerID=8YFLogxK

U2 - 10.1007/BF01371370

DO - 10.1007/BF01371370

M3 - Article

AN - SCOPUS:34250079389

VL - 67

SP - 71

EP - 80

JO - Bulletin Géodésique

JF - Bulletin Géodésique

SN - 0007-4632

IS - 2

ER -