A novel ion selective gas sensor based on pulsed atmospheric pressure chemical ionization and ion-ion-recombination

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)252-257
Seitenumfang6
FachzeitschriftSensors and Actuators, B: Chemical
Jahrgang246
PublikationsstatusVeröffentlicht - 16 Feb. 2017

Abstract

In a former work on the investigation of ion generation and ion-ion recombination kinetics at atmospheric pressure with an ion mobility spectrometer equipped with a pulsable electron emitter, we found that different ion species and concentrations could be distinguished by only considering the specific ion-ion recombination kinetics. In the present work, these findings are utilized for the development of a novel compact and simple gas sensor. In a first step, the gas mixture becomes ionized by atmospheric pressure chemical ionization for a defined ionization time. Subsequently the ionization source is turned off and the ion specific decay of the ion concentration as a function of the recombination time is measured. This decay depends on the generated ion species and the compounds of the gas mixture respectively. For the analysis of these decay curves and visualization of the results, we use discriminant analysis. As an exemplary target analyte, we chose dimethyl-methylphosphonate (DMMP). With the current setup we achieve a limit of detection of 8 ppbvfor the detection of DMMP in presence of significant higher ammonia and formaldehyde concentrations by only considering the recombination kinetics.

ASJC Scopus Sachgebiete

Zitieren

A novel ion selective gas sensor based on pulsed atmospheric pressure chemical ionization and ion-ion-recombination. / Heptner, A.; Reinecke, T.; Angerstein, N. et al.
in: Sensors and Actuators, B: Chemical, Jahrgang 246, 16.02.2017, S. 252-257.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Download
@article{4337852594164aee83c57902f7b468f4,
title = "A novel ion selective gas sensor based on pulsed atmospheric pressure chemical ionization and ion-ion-recombination",
abstract = "In a former work on the investigation of ion generation and ion-ion recombination kinetics at atmospheric pressure with an ion mobility spectrometer equipped with a pulsable electron emitter, we found that different ion species and concentrations could be distinguished by only considering the specific ion-ion recombination kinetics. In the present work, these findings are utilized for the development of a novel compact and simple gas sensor. In a first step, the gas mixture becomes ionized by atmospheric pressure chemical ionization for a defined ionization time. Subsequently the ionization source is turned off and the ion specific decay of the ion concentration as a function of the recombination time is measured. This decay depends on the generated ion species and the compounds of the gas mixture respectively. For the analysis of these decay curves and visualization of the results, we use discriminant analysis. As an exemplary target analyte, we chose dimethyl-methylphosphonate (DMMP). With the current setup we achieve a limit of detection of 8 ppbvfor the detection of DMMP in presence of significant higher ammonia and formaldehyde concentrations by only considering the recombination kinetics.",
keywords = "Atmospheric pressure chemical ionization, Discriminant analysis, Ion-ion-recombination, ppb-level",
author = "A. Heptner and T. Reinecke and N. Angerstein and S. Zimmermann",
note = "Funding information: This research is funded by the German Research Foundation (DFG ZI 1288/1-2).",
year = "2017",
month = feb,
day = "16",
doi = "10.1016/j.snb.2017.02.086",
language = "English",
volume = "246",
pages = "252--257",
journal = "Sensors and Actuators, B: Chemical",
issn = "0925-4005",
publisher = "Elsevier",

}

Download

TY - JOUR

T1 - A novel ion selective gas sensor based on pulsed atmospheric pressure chemical ionization and ion-ion-recombination

AU - Heptner, A.

AU - Reinecke, T.

AU - Angerstein, N.

AU - Zimmermann, S.

N1 - Funding information: This research is funded by the German Research Foundation (DFG ZI 1288/1-2).

PY - 2017/2/16

Y1 - 2017/2/16

N2 - In a former work on the investigation of ion generation and ion-ion recombination kinetics at atmospheric pressure with an ion mobility spectrometer equipped with a pulsable electron emitter, we found that different ion species and concentrations could be distinguished by only considering the specific ion-ion recombination kinetics. In the present work, these findings are utilized for the development of a novel compact and simple gas sensor. In a first step, the gas mixture becomes ionized by atmospheric pressure chemical ionization for a defined ionization time. Subsequently the ionization source is turned off and the ion specific decay of the ion concentration as a function of the recombination time is measured. This decay depends on the generated ion species and the compounds of the gas mixture respectively. For the analysis of these decay curves and visualization of the results, we use discriminant analysis. As an exemplary target analyte, we chose dimethyl-methylphosphonate (DMMP). With the current setup we achieve a limit of detection of 8 ppbvfor the detection of DMMP in presence of significant higher ammonia and formaldehyde concentrations by only considering the recombination kinetics.

AB - In a former work on the investigation of ion generation and ion-ion recombination kinetics at atmospheric pressure with an ion mobility spectrometer equipped with a pulsable electron emitter, we found that different ion species and concentrations could be distinguished by only considering the specific ion-ion recombination kinetics. In the present work, these findings are utilized for the development of a novel compact and simple gas sensor. In a first step, the gas mixture becomes ionized by atmospheric pressure chemical ionization for a defined ionization time. Subsequently the ionization source is turned off and the ion specific decay of the ion concentration as a function of the recombination time is measured. This decay depends on the generated ion species and the compounds of the gas mixture respectively. For the analysis of these decay curves and visualization of the results, we use discriminant analysis. As an exemplary target analyte, we chose dimethyl-methylphosphonate (DMMP). With the current setup we achieve a limit of detection of 8 ppbvfor the detection of DMMP in presence of significant higher ammonia and formaldehyde concentrations by only considering the recombination kinetics.

KW - Atmospheric pressure chemical ionization

KW - Discriminant analysis

KW - Ion-ion-recombination

KW - ppb-level

UR - http://www.scopus.com/inward/record.url?scp=85013070525&partnerID=8YFLogxK

U2 - 10.1016/j.snb.2017.02.086

DO - 10.1016/j.snb.2017.02.086

M3 - Article

AN - SCOPUS:85013070525

VL - 246

SP - 252

EP - 257

JO - Sensors and Actuators, B: Chemical

JF - Sensors and Actuators, B: Chemical

SN - 0925-4005

ER -