Details
Originalsprache | Englisch |
---|---|
Titel des Sammelwerks | 2014 IEEE Energy Conversion Congress and Exposition |
Untertitel | ECCE |
Herausgeber (Verlag) | Institute of Electrical and Electronics Engineers Inc. |
Seiten | 1188-1193 |
Seitenumfang | 6 |
ISBN (elektronisch) | 978-1-4799-5776-7 |
Publikationsstatus | Veröffentlicht - 2014 |
Abstract
This paper presents a new control method for boost DC/DC converters combined with voltage source inverter systems to minimize the DC-link capacitor-current RMS value. The examined converter system consists of a multi-phase boost converter and a three-phase inverter with common DC-link capacitor. A general analytical expression for the DC-link capacitor-current RMS value is derived, which allows to optimize the switching pattern for the boost converter phases and the DC-link voltage level. Measurements from a laboratory setup verify the analytical equations and reproduce the calculated values of the RMS current. Since the DC-link capacitor RMS current stress determines the capacitor size and is independent of the switching frequency, this work contributes to a further volume reduction of passive components especially for high frequency converter systems.
ASJC Scopus Sachgebiete
- Energie (insg.)
- Feuerungstechnik
- Energie (insg.)
- Energieanlagenbau und Kraftwerkstechnik
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
2014 IEEE Energy Conversion Congress and Exposition: ECCE . Institute of Electrical and Electronics Engineers Inc., 2014. S. 1188-1193 6953535.
Publikation: Beitrag in Buch/Bericht/Sammelwerk/Konferenzband › Aufsatz in Konferenzband › Forschung › Peer-Review
}
TY - GEN
T1 - A New Control Method for Minimizing the DCLink Capacitor Current of HEV Inverter Systems
AU - Sommer, Christian
AU - Merkert, Arvid
AU - Mertens, Axel
PY - 2014
Y1 - 2014
N2 - This paper presents a new control method for boost DC/DC converters combined with voltage source inverter systems to minimize the DC-link capacitor-current RMS value. The examined converter system consists of a multi-phase boost converter and a three-phase inverter with common DC-link capacitor. A general analytical expression for the DC-link capacitor-current RMS value is derived, which allows to optimize the switching pattern for the boost converter phases and the DC-link voltage level. Measurements from a laboratory setup verify the analytical equations and reproduce the calculated values of the RMS current. Since the DC-link capacitor RMS current stress determines the capacitor size and is independent of the switching frequency, this work contributes to a further volume reduction of passive components especially for high frequency converter systems.
AB - This paper presents a new control method for boost DC/DC converters combined with voltage source inverter systems to minimize the DC-link capacitor-current RMS value. The examined converter system consists of a multi-phase boost converter and a three-phase inverter with common DC-link capacitor. A general analytical expression for the DC-link capacitor-current RMS value is derived, which allows to optimize the switching pattern for the boost converter phases and the DC-link voltage level. Measurements from a laboratory setup verify the analytical equations and reproduce the calculated values of the RMS current. Since the DC-link capacitor RMS current stress determines the capacitor size and is independent of the switching frequency, this work contributes to a further volume reduction of passive components especially for high frequency converter systems.
UR - http://www.scopus.com/inward/record.url?scp=84934326240&partnerID=8YFLogxK
U2 - 10.1109/ECCE.2014.6953535
DO - 10.1109/ECCE.2014.6953535
M3 - Conference contribution
AN - SCOPUS:84934326240
SP - 1188
EP - 1193
BT - 2014 IEEE Energy Conversion Congress and Exposition
PB - Institute of Electrical and Electronics Engineers Inc.
ER -