A Miniaturized Ion Mobility Spectrometer for Detection of Hazardous Compounds in Air

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Autorschaft

Externe Organisationen

  • Drägerwerk AG Co. KGaA
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Titel des SammelwerksTRANSDUCERS and EUROSENSORS '07 - 4th International Conference on Solid-State Sensors, Actuators and Microsystems
Seiten1501-1504
Seitenumfang4
ISBN (elektronisch)1424408423
PublikationsstatusVeröffentlicht - 24 Sept. 2007
Extern publiziertJa
Veranstaltung4th International Conference on Solid-State Sensors, Actuators and Microsystems, TRANSDUCERS and EUROSENSORS '07 - Lyon, Frankreich
Dauer: 10 Juni 200714 Juni 2007
Konferenznummer: 4

Publikationsreihe

NameSolid State Sensors and Actuators (TRANSDUCERS)
ISSN (Print)2159-547X
ISSN (elektronisch)2164-1641

Abstract

Ion mobility spectrometry (IMS) is a well-known method for detecting hazardous compounds in air. Detection limits in the very low ppb range and fast response times of just a few seconds make this technique more and more popular. Typical applications are the detection of chemical warfare agents, toxic industrial compounds, explosives and drugs. This paper describes the concept and preliminary results of a simple, planar aspiration condenser as a miniaturized ion mobility spectrometer. Compared to other aspiration condenser IMS our system has improved separation power due to ion-focusing before ion separation. First measurements of 1-Octanol, 2-Chlorophenol and Sarin, VX and S-Mustard simulants in air demonstrate the potential of this concept.

ASJC Scopus Sachgebiete

Zitieren

A Miniaturized Ion Mobility Spectrometer for Detection of Hazardous Compounds in Air. / Zimmermann, S.; Barth, S.
TRANSDUCERS and EUROSENSORS '07 - 4th International Conference on Solid-State Sensors, Actuators and Microsystems. 2007. S. 1501-1504 (Solid State Sensors and Actuators (TRANSDUCERS)).

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Zimmermann, S & Barth, S 2007, A Miniaturized Ion Mobility Spectrometer for Detection of Hazardous Compounds in Air. in TRANSDUCERS and EUROSENSORS '07 - 4th International Conference on Solid-State Sensors, Actuators and Microsystems. Solid State Sensors and Actuators (TRANSDUCERS), S. 1501-1504, 4th International Conference on Solid-State Sensors, Actuators and Microsystems, TRANSDUCERS and EUROSENSORS '07, Lyon, Frankreich, 10 Juni 2007. https://doi.org/10.1109/SENSOR.2007.4300429
Zimmermann, S., & Barth, S. (2007). A Miniaturized Ion Mobility Spectrometer for Detection of Hazardous Compounds in Air. In TRANSDUCERS and EUROSENSORS '07 - 4th International Conference on Solid-State Sensors, Actuators and Microsystems (S. 1501-1504). (Solid State Sensors and Actuators (TRANSDUCERS)). https://doi.org/10.1109/SENSOR.2007.4300429
Zimmermann S, Barth S. A Miniaturized Ion Mobility Spectrometer for Detection of Hazardous Compounds in Air. in TRANSDUCERS and EUROSENSORS '07 - 4th International Conference on Solid-State Sensors, Actuators and Microsystems. 2007. S. 1501-1504. (Solid State Sensors and Actuators (TRANSDUCERS)). doi: 10.1109/SENSOR.2007.4300429
Zimmermann, S. ; Barth, S. / A Miniaturized Ion Mobility Spectrometer for Detection of Hazardous Compounds in Air. TRANSDUCERS and EUROSENSORS '07 - 4th International Conference on Solid-State Sensors, Actuators and Microsystems. 2007. S. 1501-1504 (Solid State Sensors and Actuators (TRANSDUCERS)).
Download
@inproceedings{f3d80a0ac050490bbd0880bb22129b7b,
title = "A Miniaturized Ion Mobility Spectrometer for Detection of Hazardous Compounds in Air",
abstract = "Ion mobility spectrometry (IMS) is a well-known method for detecting hazardous compounds in air. Detection limits in the very low ppb range and fast response times of just a few seconds make this technique more and more popular. Typical applications are the detection of chemical warfare agents, toxic industrial compounds, explosives and drugs. This paper describes the concept and preliminary results of a simple, planar aspiration condenser as a miniaturized ion mobility spectrometer. Compared to other aspiration condenser IMS our system has improved separation power due to ion-focusing before ion separation. First measurements of 1-Octanol, 2-Chlorophenol and Sarin, VX and S-Mustard simulants in air demonstrate the potential of this concept.",
keywords = "Air monitoring, Aspiration condenser, IMS, Ion mobility spectrometer",
author = "S. Zimmermann and S. Barth",
year = "2007",
month = sep,
day = "24",
doi = "10.1109/SENSOR.2007.4300429",
language = "English",
isbn = "1424408415",
series = "Solid State Sensors and Actuators (TRANSDUCERS)",
pages = "1501--1504",
booktitle = "TRANSDUCERS and EUROSENSORS '07 - 4th International Conference on Solid-State Sensors, Actuators and Microsystems",
note = "4th International Conference on Solid-State Sensors, Actuators and Microsystems, TRANSDUCERS and EUROSENSORS '07 ; Conference date: 10-06-2007 Through 14-06-2007",

}

Download

TY - GEN

T1 - A Miniaturized Ion Mobility Spectrometer for Detection of Hazardous Compounds in Air

AU - Zimmermann, S.

AU - Barth, S.

N1 - Conference code: 4

PY - 2007/9/24

Y1 - 2007/9/24

N2 - Ion mobility spectrometry (IMS) is a well-known method for detecting hazardous compounds in air. Detection limits in the very low ppb range and fast response times of just a few seconds make this technique more and more popular. Typical applications are the detection of chemical warfare agents, toxic industrial compounds, explosives and drugs. This paper describes the concept and preliminary results of a simple, planar aspiration condenser as a miniaturized ion mobility spectrometer. Compared to other aspiration condenser IMS our system has improved separation power due to ion-focusing before ion separation. First measurements of 1-Octanol, 2-Chlorophenol and Sarin, VX and S-Mustard simulants in air demonstrate the potential of this concept.

AB - Ion mobility spectrometry (IMS) is a well-known method for detecting hazardous compounds in air. Detection limits in the very low ppb range and fast response times of just a few seconds make this technique more and more popular. Typical applications are the detection of chemical warfare agents, toxic industrial compounds, explosives and drugs. This paper describes the concept and preliminary results of a simple, planar aspiration condenser as a miniaturized ion mobility spectrometer. Compared to other aspiration condenser IMS our system has improved separation power due to ion-focusing before ion separation. First measurements of 1-Octanol, 2-Chlorophenol and Sarin, VX and S-Mustard simulants in air demonstrate the potential of this concept.

KW - Air monitoring

KW - Aspiration condenser

KW - IMS

KW - Ion mobility spectrometer

UR - http://www.scopus.com/inward/record.url?scp=48349139571&partnerID=8YFLogxK

U2 - 10.1109/SENSOR.2007.4300429

DO - 10.1109/SENSOR.2007.4300429

M3 - Conference contribution

AN - SCOPUS:48349139571

SN - 1424408415

T3 - Solid State Sensors and Actuators (TRANSDUCERS)

SP - 1501

EP - 1504

BT - TRANSDUCERS and EUROSENSORS '07 - 4th International Conference on Solid-State Sensors, Actuators and Microsystems

T2 - 4th International Conference on Solid-State Sensors, Actuators and Microsystems, TRANSDUCERS and EUROSENSORS '07

Y2 - 10 June 2007 through 14 June 2007

ER -

Von denselben Autoren