Abstract

The application of the well known FMCW-method for homodyne network analysis is presented. A network analyzer based on this principle needs only a simple RF-part and therefore a more complex IF-part which makes extensive use of modern digital signal processing. The system theory is presented and explained with the help of measurements. Ameasuring system of such kind facilitates low cost, high speed measurements with a certain reduction in measuring precision. The validity of theory is proved by reflectometer measurements in X-And Ka-band.

ASJC Scopus Sachgebiete

Zitieren

A low cost homodyne reflectometer based on the FMCW method and digital signal processing. / Geck, B.; Marquardt, J.; Sagebiel, M.
1996. 799-802 Beitrag in 1996 26th European Microwave Conference, EuMC 1996, Prague, Tschechische Republik.

Publikation: KonferenzbeitragPaperForschungPeer-Review

Geck, B, Marquardt, J & Sagebiel, M 1996, 'A low cost homodyne reflectometer based on the FMCW method and digital signal processing', Beitrag in 1996 26th European Microwave Conference, EuMC 1996, Prague, Tschechische Republik, 6 Sept. 1996 - 13 Sept. 1996 S. 799-802. https://doi.org/10.1109/EUMA.1996.337699
Geck, B., Marquardt, J., & Sagebiel, M. (1996). A low cost homodyne reflectometer based on the FMCW method and digital signal processing. 799-802. Beitrag in 1996 26th European Microwave Conference, EuMC 1996, Prague, Tschechische Republik. https://doi.org/10.1109/EUMA.1996.337699
Geck B, Marquardt J, Sagebiel M. A low cost homodyne reflectometer based on the FMCW method and digital signal processing. 1996. Beitrag in 1996 26th European Microwave Conference, EuMC 1996, Prague, Tschechische Republik. doi: 10.1109/EUMA.1996.337699
Geck, B. ; Marquardt, J. ; Sagebiel, M. / A low cost homodyne reflectometer based on the FMCW method and digital signal processing. Beitrag in 1996 26th European Microwave Conference, EuMC 1996, Prague, Tschechische Republik.4 S.
Download
@conference{5e868ebf488e4e4aafe134b99d474030,
title = "A low cost homodyne reflectometer based on the FMCW method and digital signal processing",
abstract = "The application of the well known FMCW-method for homodyne network analysis is presented. A network analyzer based on this principle needs only a simple RF-part and therefore a more complex IF-part which makes extensive use of modern digital signal processing. The system theory is presented and explained with the help of measurements. Ameasuring system of such kind facilitates low cost, high speed measurements with a certain reduction in measuring precision. The validity of theory is proved by reflectometer measurements in X-And Ka-band.",
author = "B. Geck and J. Marquardt and M. Sagebiel",
year = "1996",
doi = "10.1109/EUMA.1996.337699",
language = "English",
pages = "799--802",
note = "1996 26th European Microwave Conference, EuMC 1996 ; Conference date: 06-09-1996 Through 13-09-1996",

}

Download

TY - CONF

T1 - A low cost homodyne reflectometer based on the FMCW method and digital signal processing

AU - Geck, B.

AU - Marquardt, J.

AU - Sagebiel, M.

PY - 1996

Y1 - 1996

N2 - The application of the well known FMCW-method for homodyne network analysis is presented. A network analyzer based on this principle needs only a simple RF-part and therefore a more complex IF-part which makes extensive use of modern digital signal processing. The system theory is presented and explained with the help of measurements. Ameasuring system of such kind facilitates low cost, high speed measurements with a certain reduction in measuring precision. The validity of theory is proved by reflectometer measurements in X-And Ka-band.

AB - The application of the well known FMCW-method for homodyne network analysis is presented. A network analyzer based on this principle needs only a simple RF-part and therefore a more complex IF-part which makes extensive use of modern digital signal processing. The system theory is presented and explained with the help of measurements. Ameasuring system of such kind facilitates low cost, high speed measurements with a certain reduction in measuring precision. The validity of theory is proved by reflectometer measurements in X-And Ka-band.