Details
Originalsprache | Englisch |
---|---|
Aufsatznummer | 015 |
Seiten (von - bis) | 1299-1305 |
Seitenumfang | 7 |
Fachzeitschrift | Journal of Physics D: Applied Physics |
Jahrgang | 18 |
Ausgabenummer | 7 |
Publikationsstatus | Veröffentlicht - 14 Juli 1985 |
Extern publiziert | Ja |
Abstract
The VUV line emission of a high-current DC hollow cathode was investigated in the wavelength region 10 nm to 100 nm. Spectra of quadruply ionised atoms could be observed. The radiance in the Al IV lines at 13 nm and 16 nm and in the He II Lyman-series was determined by a comparison with the spectral concentration of radiant intensity of the synchrotron radiation emitted by the electron storage ring BESSY. The authors found the radiance of the lines to be reproducible within +or-25%.
ASJC Scopus Sachgebiete
- Werkstoffwissenschaften (insg.)
- Elektronische, optische und magnetische Materialien
- Physik und Astronomie (insg.)
- Physik der kondensierten Materie
- Physik und Astronomie (insg.)
- Akustik und Ultraschall
- Werkstoffwissenschaften (insg.)
- Oberflächen, Beschichtungen und Folien
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
in: Journal of Physics D: Applied Physics, Jahrgang 18, Nr. 7, 015, 14.07.1985, S. 1299-1305.
Publikation: Beitrag in Fachzeitschrift › Artikel › Forschung › Peer-Review
}
TY - JOUR
T1 - A high-current hollow cathode as a source of intense line radiation in the vuv
AU - Danzmann, K.
AU - Fischer, J.
AU - Kuhne, M.
PY - 1985/7/14
Y1 - 1985/7/14
N2 - The VUV line emission of a high-current DC hollow cathode was investigated in the wavelength region 10 nm to 100 nm. Spectra of quadruply ionised atoms could be observed. The radiance in the Al IV lines at 13 nm and 16 nm and in the He II Lyman-series was determined by a comparison with the spectral concentration of radiant intensity of the synchrotron radiation emitted by the electron storage ring BESSY. The authors found the radiance of the lines to be reproducible within +or-25%.
AB - The VUV line emission of a high-current DC hollow cathode was investigated in the wavelength region 10 nm to 100 nm. Spectra of quadruply ionised atoms could be observed. The radiance in the Al IV lines at 13 nm and 16 nm and in the He II Lyman-series was determined by a comparison with the spectral concentration of radiant intensity of the synchrotron radiation emitted by the electron storage ring BESSY. The authors found the radiance of the lines to be reproducible within +or-25%.
UR - http://www.scopus.com/inward/record.url?scp=0022094893&partnerID=8YFLogxK
U2 - 10.1088/0022-3727/18/7/015
DO - 10.1088/0022-3727/18/7/015
M3 - Article
AN - SCOPUS:0022094893
VL - 18
SP - 1299
EP - 1305
JO - Journal of Physics D: Applied Physics
JF - Journal of Physics D: Applied Physics
SN - 0022-3727
IS - 7
M1 - 015
ER -