A fast and validated method for the determination of malondialdehyde in fish liver using high-performance liquid chromatography with a photodiode array detector

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)C484-C488
FachzeitschriftJournal of Food Science
Jahrgang79
Ausgabenummer4
PublikationsstatusVeröffentlicht - Apr. 2014

Abstract

Malondialdehyde (MDA) is a biomarker of lipid peroxidation and is present in foods and biological samples such as plasma. A high-performance liquid chromatography (HPLC) method was applied to determine MDA in fish liver samples after derivatization with 2,4-dinitrophenylhydrazine (DNPH) using a ODS2 column (10 cm × 4.6 mm, 3 μm) and a photodiode array detector. The mobile phase consisted of 0.2% acetic acid (v/v) in distilled water and acetonitrile (42:58, v/v). The present method was validated in terms of linearity, lower limit of quantification, lower limit of detection, precision, accuracy, recovery, and stability of MDA according to U.S. Food and Drug Administration (FDA) guidelines. The limit of quantification of MDA was 0.39 μmol/L, which is comparable to other methods. The recovery of the spiked MDA liver samples was in the range of 92.4% to 104.2%. This newly modified HPLC method is specific, sensitive, and accurate and allows the analysis of MDA within 4 min in fish liver but also in other tissues and plasma. Practical Application: Malondialdehyde is an established biomarker of lipid peroxidation in foods. We developed a fast, simple, and sensitive HPLC method with photodiode array detection using DNPH for derivatization of malondialdehyde in fish liver.

ASJC Scopus Sachgebiete

Zitieren

A fast and validated method for the determination of malondialdehyde in fish liver using high-performance liquid chromatography with a photodiode array detector. / Faizan, M.; Esatbeyoglu, T.; Bayram, B. et al.
in: Journal of Food Science, Jahrgang 79, Nr. 4, 04.2014, S. C484-C488.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Download
@article{a059f92222eb4c79a6680406bceb4ea6,
title = "A fast and validated method for the determination of malondialdehyde in fish liver using high-performance liquid chromatography with a photodiode array detector",
abstract = "Malondialdehyde (MDA) is a biomarker of lipid peroxidation and is present in foods and biological samples such as plasma. A high-performance liquid chromatography (HPLC) method was applied to determine MDA in fish liver samples after derivatization with 2,4-dinitrophenylhydrazine (DNPH) using a ODS2 column (10 cm × 4.6 mm, 3 μm) and a photodiode array detector. The mobile phase consisted of 0.2% acetic acid (v/v) in distilled water and acetonitrile (42:58, v/v). The present method was validated in terms of linearity, lower limit of quantification, lower limit of detection, precision, accuracy, recovery, and stability of MDA according to U.S. Food and Drug Administration (FDA) guidelines. The limit of quantification of MDA was 0.39 μmol/L, which is comparable to other methods. The recovery of the spiked MDA liver samples was in the range of 92.4% to 104.2%. This newly modified HPLC method is specific, sensitive, and accurate and allows the analysis of MDA within 4 min in fish liver but also in other tissues and plasma. Practical Application: Malondialdehyde is an established biomarker of lipid peroxidation in foods. We developed a fast, simple, and sensitive HPLC method with photodiode array detection using DNPH for derivatization of malondialdehyde in fish liver.",
keywords = "2, 4-dinitrophenylhydrazine, HPLC, Lipid peroxidation, Malondialdehyde, Polyunsaturated fatty acids",
author = "M. Faizan and T. Esatbeyoglu and B. Bayram and G. Rimbach",
note = "Copyright: Copyright 2014 Elsevier B.V., All rights reserved.",
year = "2014",
month = apr,
doi = "10.1111/1750-3841.12412",
language = "English",
volume = "79",
pages = "C484--C488",
journal = "Journal of Food Science",
issn = "0022-1147",
publisher = "Wiley-Blackwell",
number = "4",

}

Download

TY - JOUR

T1 - A fast and validated method for the determination of malondialdehyde in fish liver using high-performance liquid chromatography with a photodiode array detector

AU - Faizan, M.

AU - Esatbeyoglu, T.

AU - Bayram, B.

AU - Rimbach, G.

N1 - Copyright: Copyright 2014 Elsevier B.V., All rights reserved.

PY - 2014/4

Y1 - 2014/4

N2 - Malondialdehyde (MDA) is a biomarker of lipid peroxidation and is present in foods and biological samples such as plasma. A high-performance liquid chromatography (HPLC) method was applied to determine MDA in fish liver samples after derivatization with 2,4-dinitrophenylhydrazine (DNPH) using a ODS2 column (10 cm × 4.6 mm, 3 μm) and a photodiode array detector. The mobile phase consisted of 0.2% acetic acid (v/v) in distilled water and acetonitrile (42:58, v/v). The present method was validated in terms of linearity, lower limit of quantification, lower limit of detection, precision, accuracy, recovery, and stability of MDA according to U.S. Food and Drug Administration (FDA) guidelines. The limit of quantification of MDA was 0.39 μmol/L, which is comparable to other methods. The recovery of the spiked MDA liver samples was in the range of 92.4% to 104.2%. This newly modified HPLC method is specific, sensitive, and accurate and allows the analysis of MDA within 4 min in fish liver but also in other tissues and plasma. Practical Application: Malondialdehyde is an established biomarker of lipid peroxidation in foods. We developed a fast, simple, and sensitive HPLC method with photodiode array detection using DNPH for derivatization of malondialdehyde in fish liver.

AB - Malondialdehyde (MDA) is a biomarker of lipid peroxidation and is present in foods and biological samples such as plasma. A high-performance liquid chromatography (HPLC) method was applied to determine MDA in fish liver samples after derivatization with 2,4-dinitrophenylhydrazine (DNPH) using a ODS2 column (10 cm × 4.6 mm, 3 μm) and a photodiode array detector. The mobile phase consisted of 0.2% acetic acid (v/v) in distilled water and acetonitrile (42:58, v/v). The present method was validated in terms of linearity, lower limit of quantification, lower limit of detection, precision, accuracy, recovery, and stability of MDA according to U.S. Food and Drug Administration (FDA) guidelines. The limit of quantification of MDA was 0.39 μmol/L, which is comparable to other methods. The recovery of the spiked MDA liver samples was in the range of 92.4% to 104.2%. This newly modified HPLC method is specific, sensitive, and accurate and allows the analysis of MDA within 4 min in fish liver but also in other tissues and plasma. Practical Application: Malondialdehyde is an established biomarker of lipid peroxidation in foods. We developed a fast, simple, and sensitive HPLC method with photodiode array detection using DNPH for derivatization of malondialdehyde in fish liver.

KW - 2

KW - 4-dinitrophenylhydrazine

KW - HPLC

KW - Lipid peroxidation

KW - Malondialdehyde

KW - Polyunsaturated fatty acids

UR - http://www.scopus.com/inward/record.url?scp=84897985001&partnerID=8YFLogxK

U2 - 10.1111/1750-3841.12412

DO - 10.1111/1750-3841.12412

M3 - Article

VL - 79

SP - C484-C488

JO - Journal of Food Science

JF - Journal of Food Science

SN - 0022-1147

IS - 4

ER -

Von denselben Autoren