Details
Originalsprache | Englisch |
---|---|
Titel des Sammelwerks | Solid State Lasers XII |
Herausgeber (Verlag) | SPIE |
Seiten | 127-133 |
Seitenumfang | 7 |
ISBN (Print) | 0-8194-4768-4 |
Publikationsstatus | Veröffentlicht - 17 Juni 2003 |
Veranstaltung | High-Power Lasers and Applications - San Jose, CA, USA / Vereinigte Staaten Dauer: 25 Jan. 2003 → 31 Jan. 2003 |
Publikationsreihe
Name | Proceedings of SPIE - The International Society for Optical Engineering |
---|---|
Band | 4968 |
ISSN (Print) | 0277-786X |
Abstract
To improve the efficiency of laser phacoemulsification we developed a compact, high-repetition-rate, high-average-power, diode-pumped, 2.94 μm TIR-cavity Er:YAG laser system. Laser parameters of 19.4 % slope efficiency, 5 W of average output power at up to 300 Hz repetition rate and more than 1.5 W at 1 kHz are demonstrated. The special design results in low thermal lenses of 1.9 Dpt/W. This is a good condition for high laser system scalability.
ASJC Scopus Sachgebiete
- Werkstoffwissenschaften (insg.)
- Elektronische, optische und magnetische Materialien
- Physik und Astronomie (insg.)
- Physik der kondensierten Materie
- Informatik (insg.)
- Angewandte Informatik
- Mathematik (insg.)
- Angewandte Mathematik
- Ingenieurwesen (insg.)
- Elektrotechnik und Elektronik
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
Solid State Lasers XII. SPIE, 2003. S. 127-133 (Proceedings of SPIE - The International Society for Optical Engineering; Band 4968).
Publikation: Beitrag in Buch/Bericht/Sammelwerk/Konferenzband › Aufsatz in Konferenzband › Forschung › Peer-Review
}
TY - GEN
T1 - 3 μm diode-pumped solid state erbium laser for cataract surgery
AU - Ernst, H.
AU - Ertmer, W.
AU - Lubatschowski, H.
PY - 2003/6/17
Y1 - 2003/6/17
N2 - To improve the efficiency of laser phacoemulsification we developed a compact, high-repetition-rate, high-average-power, diode-pumped, 2.94 μm TIR-cavity Er:YAG laser system. Laser parameters of 19.4 % slope efficiency, 5 W of average output power at up to 300 Hz repetition rate and more than 1.5 W at 1 kHz are demonstrated. The special design results in low thermal lenses of 1.9 Dpt/W. This is a good condition for high laser system scalability.
AB - To improve the efficiency of laser phacoemulsification we developed a compact, high-repetition-rate, high-average-power, diode-pumped, 2.94 μm TIR-cavity Er:YAG laser system. Laser parameters of 19.4 % slope efficiency, 5 W of average output power at up to 300 Hz repetition rate and more than 1.5 W at 1 kHz are demonstrated. The special design results in low thermal lenses of 1.9 Dpt/W. This is a good condition for high laser system scalability.
UR - http://www.scopus.com/inward/record.url?scp=0141717109&partnerID=8YFLogxK
U2 - 10.1117/12.478260
DO - 10.1117/12.478260
M3 - Conference contribution
AN - SCOPUS:0141717109
SN - 0-8194-4768-4
T3 - Proceedings of SPIE - The International Society for Optical Engineering
SP - 127
EP - 133
BT - Solid State Lasers XII
PB - SPIE
T2 - High-Power Lasers and Applications
Y2 - 25 January 2003 through 31 January 2003
ER -