Details
Datum der Bereitstellung | 2024 |
---|---|
Herausgeber (Verlag) | Forschungsdaten-Repositorium der LUH |
Beschreibung
All measurements taken with Modular Compact Series of Anton Paar AG rheometer at Institut für Transport- und Automatisierungstechnik (ITA) of the Leibniz Universität Hannover (LUH).
All measurements taken by Lennart Mesecke @IPeG under supervision of Tobias Biermann @IPeG.
All measurements taken at roomtemperature R_T=20°C.
The material was analyzed regarding viscosity und shear stress under given shear rates.
Test series A contains measurements with shearrates from 0-200 1/s. B contains measurements with shearrates from 0-50 1/s, focussing on lower shear rates.
The analyses file contains the evaluated Herschel-Bulkley-parameters. Please note, that the Herschel-Bulkley-parameters unsufficiently fit the measurement data due to wall-slip effects during the measurements.
The measurements therefore should be viewed with caution, since wall-slip effect leads to underestimating the yield stress of the material.
All measurements taken by Lennart Mesecke @IPeG under supervision of Tobias Biermann @IPeG.
All measurements taken at roomtemperature R_T=20°C.
The material was analyzed regarding viscosity und shear stress under given shear rates.
Test series A contains measurements with shearrates from 0-200 1/s. B contains measurements with shearrates from 0-50 1/s, focussing on lower shear rates.
The analyses file contains the evaluated Herschel-Bulkley-parameters. Please note, that the Herschel-Bulkley-parameters unsufficiently fit the measurement data due to wall-slip effects during the measurements.
The measurements therefore should be viewed with caution, since wall-slip effect leads to underestimating the yield stress of the material.